SALAMANDRES SGF 800 Скачать руководство пользователя страница 16

General conditions of installation

 

 

The installation and maintenance of the appliance must be carried out in compliance 
with the statutory texts and good practices in force, mainly:

 

  

General specifications

 

 

For all appliances:

 

Article GZ

 

Installation with combustible gases and liquefied hydrocarbons.

 

  

Then, according to use:

 

Article CH

 

Heating, ventilation, refrigeration

 

Air conditioning and domestic hot water steam generation.

 

 

Article GC

 

Installation of appliances to be used for catering

 

Specific  provisions  for  each  type  of  establishment  to  which  the  public  is  admitted 
(hospitals, shops, etcP)

 

 

Important: Never change the diameter of the injectors.

 

16

 

Содержание SGF 800

Страница 1: ...NDRES GAZ INSTRUCTION FOR USE AND INSTALLATION GAS SALAMANDERS SGM 600 SGM 800 SGF 800 Fabrication fran aise Fabrication fran aise Fabrication fran aise Fabrication fran aise Made in France Made in Fr...

Страница 2: ...e Ne laisser jamais l appareil fonctionner sans surveil lance Tenir compte du mode d emploi conserver syst ma tiquement avec l appareil Installer toujours l appareil en respectant les con signes Une d...

Страница 3: ...ne pas ou blier de couper l arriv e du gaz 2 CONTENU DU CARTON D EMBALLAGE Appareil Une salamandre Accessoires Un plat Une grille de plat Une grille poign e SGF 800 Une pochette plastique avec les in...

Страница 4: ...le plafond n 2 sur la photo de pousser et de tourner le bouton du robinet n 1 sur la photo vers la gauche sur la position toile Maintenir le bouton pendant 15 secondes afin que la veilleuse reste allu...

Страница 5: ...ne soient constitu s d un mat riau non combustible ou recouverts d un mat riau isolant thermique non combustible et accorder une attention particuli re aux r glements de pr vention des incendies b Pr...

Страница 6: ...eil doivent tre effectu s conform ment aux textes r glementaires et r gles de l art en vigueur notamment Prescriptions g n rales Pour tous les appareils Article GZ Installation aux gaz combustibles et...

Страница 7: ...nemark II2H3B P G20 20 130 R glable Sans Finlande G30 G31 28 30 30 85 110 Sans Espagne II2H3 G20 20 130 R glable Sans G30 G31 28 30 37 85 110 Sans II2H3P G20 20 130 R glable Sans G31 50 75 95 Sans II2...

Страница 8: ...G31 28 30 37 100 110 Sans II2E 3B P G20 G25 20 25 150 R glable Sans G30 G31 50 90 95 Sans Allemagne II2E3B P G20 G25 20 150 160 R glable Sans G30 G31 50 90 95 Sans Autriche II2H3B P G20 20 150 R glab...

Страница 9: ...n du robinet vers la gauche sur la position toile 3 Maintenir le robinet appuy pendant 15 secondes afin que la veilleuse reste allu m e 4 Le br leur reste alors allum et il est d sormais possible d au...

Страница 10: ...quide vaisselle viter les ponges abrasives Rincer votre appareil l aide d une ponge humide Ne jamais nettoyer votre appareil sous un jet d eau les infiltrations risqueraient de l endommager de fa on i...

Страница 11: ...de la garantie les r parations n cessit es par suite de fausses man uvres d usage inappropri de n gligences ou de surcharges de l appareil ain si que celles r sultant d installations d fectueuses Les...

Страница 12: ...orking without any watch ing Take into account the instructions to be systematically kept with the appliance Install the appliance always in instructions respect A 40 cm distance minimum with the part...

Страница 13: ...ce a salamander Accessories A tray A grid A grid with handles SGF 800 A set of natural gas injectors burner pilot light The present note See exploded views for each models at the end of the document 3...

Страница 14: ...sed for 15 seconds The burner then re mains lit While cooking the temperature can be regulated using the control knob n 1 on pic ture from high flame to low flame in order to avoid over cooking A safe...

Страница 15: ...he first use warm your machine up outside during about 30 min to evacuate residual smokes of manufacturing oil from the metallic parts This may emit a slight smell for a few moments First cleaning Cle...

Страница 16: ...Article GZ Installation with combustible gases and liquefied hydrocarbons Then according to use Article CH Heating ventilation refrigeration Air conditioning and domestic hot water steam generation A...

Страница 17: ...ark II2H3B P G20 20 130 Adjustable Without Finland G30 G31 28 30 30 85 110 Without Spain II2H3 G20 20 130 Adjustable Without G30 G31 28 30 37 85 110 Without II2H3P G20 20 130 Adjustable Without G31 50...

Страница 18: ...25 150 Adjustable Without G30 G31 50 90 95 Without Germany II2E3B P G20 G25 20 150 160 Adjustable Without G30 G31 50 90 95 Without Austria II2H3B P G20 20 150 Adjustable Without G30 G31 50 90 95 Witho...

Страница 19: ...Keep the control knob n 1 on picture pressed for some more seconds The burner then remains lit and it is now possible to increase the power by turning the power control knob n 1 on picture Temperature...

Страница 20: ...guarantee applicable to any device is the commercial guarantee of the distributor or the retailer Please contact the store where you bought your device to know the precise conditions The guarantee gra...

Страница 21: ...at the risks of the user in case of delivery by carrier the consignee has to have reservations towards the carrier before any delivery of the device The guarantee comes to an end in case of interventi...

Страница 22: ...22 Nomenclature SGM 600 Spare parts SGM 600...

Страница 23: ...23...

Страница 24: ...24 Nomenclature SGM 800 Spare parts SGM 800...

Страница 25: ...25...

Страница 26: ...26 Nomenclature SGF 800 Spare parts SGF 800...

Страница 27: ...27...

Страница 28: ...G03228...

Отзывы: