11 - Salamander Range Eco performance results
Output and Efficiency
All efficiencies in table are Net values
Wood Logs Results, 0.80 hour refuels
Parameter
A20/181
-1
A20/181
-2
A20/181
-3
Mean
Test duration
h
0.87
0.83
0.83
0.84
Total efficiency
%
86.0
86.0
85.1
85.7
Nominal heat output
kW
4.1
4.4
4.3
4.3
Mean CO emission (at 13 %
O
2
)
%
0.06
0.06
0.06
0.06
Mean flue gas temperature
ºC
187
193
189
190
Flue gas mass flow
g/s
3.4
3.4
3.8
3.5
Mean C
n
H
m
emission (at 13
% O
2
)
Nmg/m
3
74
88
72
78
Mean NOx emission (at 13 %
O
2
)
Nmg/m
3
75
66
76
72
DIN Plus particulates (at 13
% O
2
)
Nmg/m
3
18
20
15
18
Maxibrite Results, 1.0 hour refuels
Parameter
A20/179
-1
A20/179
-2
Mean
Test duration
h
1.05
1.03
1.04
Total efficiency
%
83.8
82.9
83.4
Nominal heat output
kW
4.2
4.2
4.2
Mean CO emission (at 13 %
O
2
)
%
0.04
0.04
0.04
Mean flue gas temperature
ºC
197
195
196
Flue gas mass flow
g/s
3.1
3.3
3.2
Mean C
n
H
m
emission (at 13
% O
2
)
Nmg/m
3
33
34
34
Mean NOx emission (at 13 %
O
2
)
Nmg/m
3
125
105
115
DIN Plus particulates (at 13
% O
2
)
Nmg/m
3
26
20
23
Distances to Combustible Materials (Twin Wall Flue)
Rear and side heat shields fitted:
Back wall = 200mm
Side wall = 250mm
Rear and side heat shields removed:
Back wall = 500mm
Side wall = 450mm