Outside
Zones
Outside
Zones
Zone 0
Zone 1
Zone 2
Outside Zone
Space under shower is Zone 1
if accessible without tool
Window recess Zone 2
2
2
2
2
2
1
1
0.6m
0.6m
2
0
Outside
Zones
Outside
Zones
2
2
2
2
2
11
0.6m
0
0.6m
OutsideZ ones
Zone 0
Zone 1
Zone 2
Outside Zone
Space under bath is Zone 1
if accessible without tool
Window recess Zone 2
8
6. Additional Safety Instructions for Bathroom
& Shower Room Installations
The TapBoost pump can be installed within Zone 2, however it is important
that the electrical power supply unit is located beyond Zone 2 and ideally
outside of the bathroom. The electrical power supply unit and mains plug must
be protected against moisture and water. The plug must be located outside of
the bathroom. The installation must be carried out to comply with the latest
wiring/electrical regulations, building regulations and local byelaws.
IF YOU ARE UNSURE, CONSULT A QUALIFIED ELECTRICIAN.
There are 3-bathroom electrical zones that have been identified in the IET wiring
regulations and these are:
Zone 0
- bath, basin or shower tray and is defined as ‘any area within a bathroom
that can hold water’.
Zone 1
- the area directly above zone 0 to the height of 2.25m from the bottom
of the bath or shower. It also covers the width of the shower cubicle and length of
the bath or basin.
Zone 2
- the area stretching 600mm beyond zone 1, outside of the bath or
shower, be that above or to the sides of each.
Figure 8 - Power supply unit and plug located outside of bathroom
Figure 7 - Bathroom Zones