Additional Water Storage Tanks
-
Additional storage tanks must be the same size as the main pumped unit.
-
All tanks must be located on the same level and as close together as possible so as
not to restrict movement of water between the tanks.
-
Total volume of stored water must not be more than will be used in a single day.
-
The supplied tank connector kit should be used to link the tanks.
1. Remove the inlet float valve from the main
tank with the pump/control unit.
2. Insert the supplied bung into the resulting
hole.
3. Remove the tank link plug from the main
tank.
4. Attach the supplied threaded push-fit
connectors to each tank ensuring a
watertight seal is made.
5. Position the tanks side by side on a flat level
surface capable of supporting the weight of
both units when filled.
6. Assemble the linking kit as shown below.
Step 1:
pipe inserts should be pushed
into each pipe end.
Step 2:
pipes and drain plug should be pushed
into each push-fit connector as shown,
ensuring a watertight fit and that the collars
have been tightened.
7. Insert the assembled linking kit into the
push fit connectors on the tanks, ensuring
a watertight fit. Note, ensure the pipes are
fully inserted and that the collar on the
push-fit has been tightened.
8. It is important that the mains water inlet is
connected to the tank without the pump to
ensure a good turnover of water within the
tanks.
9. Continue to follow the installation
instructions from page 6. Refer to the
typical installation diagrams on page 7 for
further guidance.
Tank link plug
Threaded push-fit
connectors
PumpWise and Warranty
Monday – Thursday
8.30am - 4.30pm
Friday
8.30am – 2.30pm
PumpWise is the cornerstone of Salamander’s
support service to our customers and the means
by which our customers are guaranteed:
• Selection of the right pump for the job
With more than 30 pumps in our range, the
PumpWise team can help you to choose the
pump that’s most suitable to your specific
installation.
• The avoidance of installation pitfalls
Due to the technical nature of our products,
it is essential that they are fitted according
to our installation guidelines. The PumpWise
team are available to talk through any
installation questions and provide technical
support and guidance.
• Warranty
TankBoost has a two year warranty.
Our PumpWise commitment
Our PumpWise helpline is here to help you and we
aim to provide a support service second to none.
Installers and consumers can be sure of a speedy
response to requests for technical help, guidance,
and advice.
Your warranty
TankBoost comes with a two year warranty.
This warranty will operate from the date of
purchase and is subject to the installation
guidelines being followed correctly (please refer
to our installation notes and our Commissioning
checklist).
Please complete the warranty registration online
at www.salamanderpumps.co.uk or by calling
0191 516 2002.
For further details please contact the
PumpWise team:
Telephone:
0191 516 2002
Email:
PLEASE NOTE:
Incorrect installation will
invalidate the unit warranty. Please fully read the
following terms and conditions.
To the installer
Please follow the guidelines for the installation
provided in this brochure and call the PumpWise
helpline for installation advice. Once installation
has been completed and the system has been
tested to your satisfaction, please assist the
customer by giving them the information needed
to complete the online warranty registration.
Please note that Salamander are able to provide
an onsite service visit which may be chargeable.
WEEE Directive
Your appliance contains valuable materials which
could be recovered or recycled. At the end of the
product’s useful life please dispose of it at an
appropriate civil waste collection point.
WEEE Directive 2012/19/EU
At the end of the product life dispose
of packaging and product in a
corresponding recycling centre. Do not
dispose of the unit with the usual
domestic refuse. Do not burn the
product.
14
15
Содержание TankBoost Series
Страница 10: ...18 19...