Technical Specification
Part Number
TNK-100-SUB TNK-200-SUB TNK-350-SUB TNK-450-SUB
Warranty
2 years
Useable Water
Tank Size (litres)
100
200
350
450
Dimensions
Height (mm)
911
1406
1406
1670
Width (mm)
520
520
600
600
Depth (mm)
500
500
640
640
Weights
Empty Weight (kg)
37.9
48.7
61.5
67.0
Filled Weight (kg)
137.9
248.7
411.5
517.0
Pump
Pump Type
Submersible Centrifugal Multi-Stage Pump
Pump Body/Impeller
Stainless Steel
Enclosure Protection
IPX8
Electrical
Power Supply
230V, 50Hz
Current (Full Load)
4.2A
Power Consumption
730W
Cable Length
8m (Plug not supplied)
Fuse Rating
5A
Connections
Inlet Connection
1/2” BSP Male
Outlet Connection
1” BSP Female
Performance
Maximum Pressure
3 Bar/ 300 kPa
Maximum Flow Rate
80lpm
Water Temperature
4°C - 20°C
Pressure Vessel
8L Vessel with 1.5 Bar Air Pre-Charge
Part Number
TNK-100
TNK-200
TNK-350
TNK-450
Warranty
2 years
Dimensions
Height (mm)
840
1350
1350
1600
Width (mm)
520
520
600
600
Depth (mm)
500
500
640
640
Weights
Empty Weight (kg)
22.2
32.9
45.7
51.1
Filled Weight (kg)
122.2
232.9
395.7
501.1
Connections
Inlet Connection
1/2" BSP Male
Linking Connection
Via Linking Kit Supplied
Water Temperature
4°C - 20°C
The company operates a policy of continuous development and reserves the right to change any of the specifications of its
products without prior notice. All information data and illustrations given in this leaflet may be subject to variation.
Troubleshooting
Fault
Probable Cause
Recommended Solution
Unit will not
start
Electrical
Check power supply.
Check fuse.
Check circuit breaker.
Check display on control unit – refer to fault codes on page 12..
Inlet/Outlet
Connections
Check that the connections are plumbed in the correct way round
and all valves are open as per installation diagram.
Check that an outlet is open to allow water flow.
Insufficient
stored water
Check that the mains stop tap is open.
Check the tank is full before start up.
TankBoost stores water. When this has been consumed, the pump
will turn off and periodically restart to re-pressurise the system.
Wait for the tank to refill before trying further actions. Additional
stored water tanks can be connected if required. Total water
storage should not exceed estimated system water usage for a
24hr period.
Check all isolating valves are open before the unit.
Reduced/
Intermittent
flow
Restricted outlets Check there is no blockages or leaks in the pipework being fed by
the unit.
Pump starts
with all outlets
closed
Leak in system
Check for leaks on pipework supplied by the unit.
Outlet open
Ensure all outlets are fully closed or capped – i.e. no dead legs in
pipework.
Unit is noisy
Air in system
Open all outlets and discharge air.
Check stored water volume.
Base site uneven/
not level
Ensure unit is fully supported across its entire base. Surface
should be flat and level, capable of supporting filled tank weight as
per specification table. Unit could be located on top of a carpet/
mat to dampen vibrations.
Unit is leaking
Tank has suffered
chemical damage
Ensure that no part of the TankBoost unit has come into contact
with chemical substance e.g. solder flux.
Unit exposed
to extreme
temperature
Ensure adequate frost protection.
Unit appears to
have leaked but
not sure
Check any surrounding pipework for leaks.
Check condensation build up – large volumes of cold stored water
can allow condensation to form on the tank faces. Insulate tank.
Unit does
not switch
off when all
outlets closed
Outlet open
Ensure all outlets are fully closed or capped and check all pipework
for leaks.
Pressure sensor
calibration
Contact Salamander Pumps.
10