Pre-installation

Installation

PumpWise guidelines

General specification

Trouble shooting

PumpWise and warranty

General specification

Applications

All Salamander pumps are designed to 

boost low pressure hot and cold supplies 

from tank-fed services. 

Voltage

220-240 volts 50 Hz.

Motor type

Capacitor start and run induction type 

motor with stainless steel shaft and in-built 

resetting thermal protection (complies 

with BS5000 part 11).

Pump materials

All moulded components are manufactured 

from Acetal Copolymer.

Maximum head

RP 50 TU and RP 55 SU                  5 metres
All other pumps 

10  metres

Pumps fitted with RCM3 maximum 3 

metres static head. 

Pump noise

With the technological advances achieved 

in Right pumps, Salamander has taken 

another step forward in the quest to 

supply all our customers with even quieter 

centrifugal pumps. Despite this no pump is 

completely silent. 
Correct installation will minimise vibration 

and transmission noise. 

Patents

Our Right range of pumps is protected 

by following patent: Hydraulic Pump - 

GB2402444

Mechanical seals

Scale deposits in water supplies can cause 

the mechanical seal to stick if left for long 

periods without use. We recommend the 

pump be ran at least five minutes every  

four weeks to ‘exercise’ all working parts.

Connections

3⁄4” BSP male.

Initiation

Fully automatic, flow switch operated, 

requiring 1 litre in 30 sec per side  or  

2 litre in 30 sec mixed. Except Right 

Universal pumps when required to operate 

in negative  

head mode.

Temperature

Maximum fluid temperature 60ºC.

Standards and approvals

Splash proof rating IPX2.
Complies with the requirements of current 

British and European safety standards for 

household and similar electrical appliances.
Complies with European Community 

Directives (CE).
The company operate a policy of 

continuous development and reserves the 

right to change any of the specifications 

of its products without prior notice. All 

information data and illustrations given in 

this leaflet may be subject to variation.

Содержание RP55PS

Страница 1: ...Salamander Pumped Shower Systems Limited Unit 2c Colima Avenue Sunderland SR5 3XE Tel 0191 516 2002 Fax 0191 548 4445 Email service salamanderpumps co uk...

Страница 2: ...Pre installation Installation PumpWise guidelines General specification Trouble shooting PumpWise and warranty...

Страница 3: ...ve you first rate advice regarding installation Consulting the helpline at the time of installation could entitle your customer an additional year s warranty FREE UK only all you have to do is call us...

Страница 4: ...indication 7 Typical installations Right universal pumps 9 Commissioning 11 Helpful PumpWise guidelines 12 Cold water supplies and storage Helpful PumpWise guidelines 14 Water starvation protection p...

Страница 5: ...equivalent to 100kPa 1 0 bar pressure only exception is the RP50TU which is 5m equivalent to 50kPa 0 5 bar pressure We recommend the pump is activated for at least 5 minutes every 4 weeks Don ts Never...

Страница 6: ...should be a maximum of 4m from the cylinder in 22mm pipe work All up and over pipe work must be vented at Please follow these installation instructions carefully Failure to install your pump in accor...

Страница 7: ...fit to top entry flange if the pump is fitted above the cylinder Pump at the base of cylinder Outlets OR ALTERNATIVELY 22mm No Stop Essex flange with 76mm dip pipe and birds beak cut end to limit air...

Страница 8: ...the pump inlet on the side and the straight coupler should be attached to the pump outlet on the top Each twin pump is supplied with four couplers two angled and two straight For all pumps the inlets...

Страница 9: ...e head Usable capacity minimum 50 gallons per bathroom The hot connection must be via an approved side or top entry flange see page 16 Vent and other services Cold water storage H C Outlet Inlet Outle...

Страница 10: ...p ends are identified by RED hot and BLUE cold tie System malfunction is indicated by three L E D s located on the top of the pump junction box see Figure 9 NON RETURN VALVES MUST NOT be fitted in the...

Страница 11: ...If the distance between the bottom of the cold water cistern and the highest point of the system after the pump is 2 feet 610mm or less it is also possible that a universal pump will be required Sala...

Страница 12: ...ight Universal pump The following systems are best accommodated by using a single ended Right Universal pump which is complete with a pressure vessel and electronic system protection Right universal p...

Страница 13: ...C ed Usable capacity minimum 50 gallons per bathroom Double acting non return valves must be fitted to cold inlets of any shower valve or mixer tap Tank fed hot with cold water mains systems MUST use...

Страница 14: ...ork is connected to the pump The best method is Figure 19 DO NOT RUN PUMP DRY to do so will cause irreparable damage to your pump and will invalidate your warranty Open shower mixer valve system outle...

Страница 15: ...he cold tank MUST be checked and cleaned of debris Chronicaerationofthepumpoccurswhen thisproblemiscombinedwithinadequate storagecapacityand orwhenthevolumeof waterdrawnbythepumpandother services exce...

Страница 16: ...ater storage Immersion heater and an indirect connection to a boiler Lid H C Figure 22 Pre plumbed direct or indirect combination units Elson type tanks In these systems it is important to ensure the...

Страница 17: ...tarvation Figure 25 Water starvation protection unit WSP Shower head size vs bar pressure The size of a shower head dictates the bar pressure of the pump required to deliver the expected performance o...

Страница 18: ...l cylinders As horizontal torpedo cylinders are problematic for boosted systems consult PumpWise for guidance and correct use of an approved top entry flange Fig 25 Horizontal cylinders Use any of the...

Страница 19: ...n the supply pipe work to the pump particularly on the hot side as illustrated is likely to interfere with the initiation and smooth operation of the pump restrict the supply water to the pump and ris...

Страница 20: ...ot water temperature Extract from BS5546 1990 Current The mean temperature of the stored water should not normally exceed 60 C and in a combined central heating and domestic Fig 29 HWS Blending MAX 60...

Страница 21: ...ill minimise vibration and transmission noise Patents Our Right range of pumps is protected by following patent Hydraulic Pump GB2402444 Mechanical seals Scale deposits in water supplies can cause the...

Страница 22: ...3 3 bar Pressure Closed head 1 5 bar 2 0 bar 3 1 bar 1 5 bar 2 4 bar 3 6 bar Maximum Water Temperature 60 C Connections Pump Connections 3 4 BSP Flexible hoses Connections UK Model 3 4 Female x 22mm p...

Страница 23: ...r 2 1 bar 3 0 bar 1 5 bar 2 3bar 3 4 bar Maximum Water Temperature 60 C Pressure Vessel Air Pre Charge 8 psi 14 psi 20 psi 8 psi 14 psi 20 psi Connections Pump Connections 3 4 BSP Flexible hoses Conne...

Страница 24: ...f 2l min required on both hot and cold Float sticking in outlet Ensure no debris is in outlet area Flow switch malfunction Contact PumpWise on 0191 5162002 Pump will not start Right Universal pumps ad...

Страница 25: ...ted as described in instructions Wrong size pump for system Ensure pump is sufficient to run the equipment Hot temp set too high Reduce cylinder stat setting to 60 C max or fit HWS TMV Pump starts wit...

Страница 26: ...quests for technical help guidance and advice Your warranty Salamander customers benefit from a full two year warranty on the Right pump range This warranty will operate from the date of purchase and...

Страница 27: ...stalled in accordance with the installation instructions guidance and advice contained within the installation and warranty guide and or provided by the Salamander help desk b You are the original pur...

Страница 28: ...25 Pre installation Installation PumpWise guidelines General specification Trouble shooting PumpWise and warranty Notes...

Страница 29: ...Freepost RLXE JHHY HLHJ DDATTDTFDADDTADDTTFATTDADFDDATDDDFDD Freepost RLXE JHHY HLHJ Salamander Pumps Unit 2c Colima Avenue Sunderland SR5 3XE DDATTDTFDADDTADDTTFATTDADFDDATDDDFDD...

Отзывы: