5
of the cisterns level.
Never put a non-return valve, restricted ballofix or an air vent on the supply pipework to the
pump.
The stored hot water temperature must not exceed 60ºC.
Ensure that the hot supply to the pump is via a Salamander approved method. (Figure 2, 4 &
5 Pages 5&7).
Jointing compounds (boss white, hemp and steel wool) must not be used. Solder fluxes must
not come into contact with the pump.
The anti-vibration hoses must not be twisted or bent.
Higher rated fuses must not be used.
Cold water storage
Inlet
Min 600mm
Air vents,
both hot
and cold
Outlet
Vent and
other services
No Stop Essex Flange
MUST
be used with
an anti-gravity loop at
least 200mm in depth
MAX
60°C
MAX
60°C
Inlet
Outlet
Figure 2: Anti-gravity loop - pumps above the hot water cylinder
The best method is the no
stop Essex Flange with an
anti-gravity loop at least
400mm in depth