8
Installation
Specifications
Trouble shooting
PumpWise
Warranty
Step 2: Connecting the pump
Use only Salamander supplied hoses to
connect the pump.
The in-line strainers must be fitted to the hot
and cold inlet supplies to the pump.
It is critical to discharge water through the
pump into a container before connecting
the pump to outlet pipework in order to
ensure the air has been discharged from inlet
pipework and pump chambers. This will not
happen if the outlet pipework is connected
to the pump.
All associated pipework MUST be thoroughly
flushed before making final connections to
the pump. Fill the pump with water before
connecting to the discharge pipework.
A Hose to pipework
All FORCE pumps are fitted with ¾ inch
BSP x 22mm push fit connectors with
built in isolating valves.
The anti-vibration coupler nuts need only
be finger tight plus one quarter turn.
Mechanical tools must not be used to
tighten coupler nuts as this may cause
damage which will invalidate the warranty.
B Hose to pump
Do not twist or bend anti-vibration hoses as
this will invalidate the warranty.
35°
Do not bend hoses
more than 35°
Isolating valve
shown in
‘ON’ position
Isolating valve
shown in
‘OFF’ position
Do not twist or
kink the hose