Commissioning

Before you finish

• Check the pump inlet filter is fitted
• With HomeBoost™/CombiBoost installed, flush the inlet pipe work and fully fill the pump with 

water by opening all the water outlets BEFORE electrically switching the pump on. 

It is critical to discharge water through the pump through;

1. all the cold outlets on a whole house application.

or

2. all the hot outlets for a combi boiler boost application. Using natural flow before switching the 

pump on electrically. This will ensure that the air has been discharged from the connecting pipe 

work and pump chamber.

The best method is:
1   Connect pump pipe work
2   Check that all isolating valves are open
3   Turn mains water on at the stop tap
4   Ensure all air is purged from the system
5   Check for natural flow on the cold outlets (or hot outlets for a combi boost installation)
6   Inspect connecting pipe work for leaks
7   Plug in electrical supply to pump
8   Turn mains electrical supply on
9   Green pump lights in the logo label should be lit and steady. This indicates that the power  

 

is on and that the pump is ready for use (HomeBoost™ only)

10   Turn a pumped outlet on
11   HomeBoost™/CombiBoost should activate. The green lights should rotate, indicating   

that the pump is in operation (HomeBoost™ only).

If the HomeBoost™/CombiBoost does not activate, please refer to the 

trouble shooting section of these application notes. 

General specifications

Applications

HomeBoost™/CombiBoost pumps are designed to boost low mains water flow into a domestic 

house to improve low water flow from the mains supply at peak demand times. These pumps can 

be used in two distinct applications:
1. Boosting the incoming mains water supply to a whole house
2. Boosting the inlet mains water supply solely to a combination (combi) boiler.
HomeBoost™ will increase the low incoming water flow up to 12 lpm and CombiBoost will increase 

to 10 lpm which comply with the Water Supply (Water Fittings) Regulations 1999. HomeBoost™ 

will adapt to maintain 12 l/min, and will move into idle if sufficient flow is received from the water 

main. 

Power supply 

230 volts, 50Hz, 1.8A, continuously rated.

Pump noise 

The HomeBoost™ pump has been awarded the quiet mark, demonstrating that it is one of the 

quietest pumps available in its category. However, no pump is completely silent and this type of 

pump is characterised by a high pitched hum or whine.

Mechanical seals

Scale deposits in water supplies can cause the mechanical seal to stick if left for long periods 

without use. We recommend that the pump be run for at least five minutes every four weeks to 

‘exercise’ all the working parts.

Connections

¾

” BSP male.

Initiation

Fully automatic, water flow operated, requiring 3 litres per minute flow rate to initiate.

Temperature

Maximum fluid temperature is UK cold water mains temperature (max 20°C).

Standards and approvals

• WRAS approved product
• Complies with the Water Supply (Water Fittings) Regulations 1999
• Splash proof rating IPX4
• Complies with European Community Directives (CE)
• Tested for sound power level in accordance with methods set out in BS EN ISO 3744:2010 and 

Содержание CombiBoost

Страница 1: ...ISSUE 1 JULY 2020 Pumpinstallationandwarrantyguidefor CombiBoostandHomeBoost HomeBoost only...

Страница 2: ...l water flow reaches 12lpm or more naturally CombiBoost is designed to boost your existing incoming mains water supply up to 10 litres per min lpm Correct installation is essential for safe operation...

Страница 3: ...ressure of 1MPa 10 bar In line with good plumbing practice and water regulations ensure that a non return valve has been fitted directly after the mains stop tap to the house Earth continuity must be...

Страница 4: ...similarly qualified person in order to avoid a hazard All pipe work must be cross bonded in accordance with the IETRegulations HomeBoost CombiBoost is supplied with a 3A fuse fitted Higher rated fuse...

Страница 5: ...designed to boost low mains water flow into a domestic house to improve low water flow from the mains supply at peak demand times These pumps can be used in two distinct applications 1 Boosting the in...

Страница 6: ...p running Fault Probable cause Recommended solution Pump will not start Electrical Check power supply appliance plugged in and electrical power on Check fuse Check circuit breaker Inlet outlet connect...

Страница 7: ...o provide a support service second to none Installers and consumers can be sure of a speedy response to requests for technical help guidance and advice Yourwarranty HomeBoost comes with a three year w...

Страница 8: ...e helpline for installation advice Once installation has been completed and the system has been tested to your satisfaction please assist the customer by giving them the information needed to complete...

Страница 9: ...teryourwarranty Apply online at www salamanderpumps co uk Apply by phone 0191 516 2002 HomeBoost only Getintouch we reheretohelp calluson 01915162002 Unit2cColimaAvenue EnterpriseParkWest Sunderland S...

Отзывы: