19
is not available on your installation. In that case the controller will give the alarm sound and no any
action will effect on the unit.
Switching on and setting space cooling (
) and heating (
)
1. Use the
button to select space cooling or space heating.
Icon
or appears on the display as well as the corresponding water temperature set point.
2. Use the
or
button to set the desired water temperature.
·
Temperature range for heating: 25
℃
to 55
℃
.
·
Temperature range for cooling: 5
℃
to 22
℃
.
3. Switch on the unit by pushing the
button. The operation LED
○
○
lights up.
Selection and setting of domestic water heating
1. Use the
button to activate domestic water heating
. Icon
appears on the display.
2. Use the
or
to set the desired domestic water temperature.
Temperature range for domestic water heating: 30
℃
to 80
℃
.
NOTE
Remark that pushing the
button has no influence on the domestic water heating.
Domestic water heating is only switched on or off by means of the
button.
Selecting powerful domestic water heating operation
Press
for 5 seconds to activate powerful domestic water heating operation.
Icons
and
start flashing.
Power domestic water heating is deactivated automatically when the set point for the domestic
hot water is reached.
Checking actual temperatures
Each time the
button is pressed, the screen will display the next temperature item. The sequence as below:-
T1 Indoor temperature
T2 Outdoor temperature
T3 Outdoor coil temperature
T4 Water pump outlet temperature
T5
T6
T5, T6 display “—“
The hot water temperature display section will show the certain No. and the relating actual temperature. The display
temperature range is -9
℃
-85
℃
. If no button is pressed for 30 seconds the temperature check will return to display
setting temperature.
Schedule timer operation
In schedule timer operation, the installation is controlled by the schedule timer. The action
programmed in schedule timer will be executed automatically.
The schedule timer always follows the last command until a new command is given. This means that
T1
T3
T2
T6
T4
T5
Содержание SXAO-110HAS
Страница 4: ...3 PARTS AND DESCRIPTIONS Indoor unit all models External ...
Страница 7: ...6 Outdoor unit External SXAO 110HAS and SXAO 140HAS ...
Страница 9: ...8 Outdoor unit External SXAO 160HAS 3 ...
Страница 26: ...25 WIRING DIRGRAM All models Indoor ...
Страница 27: ...26 SXAO 11HAS and SXAO 14HAS Outdoor ...
Страница 28: ...27 SXAO 160HAS 3 Outdoor ...