Light Commercial R410A on-off
S13-01.01.13en
Notes:
1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27
°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 7.5m(horizontal)
2. Nominal heating capacities are based on the following conditions:
Indoor temp: 20
°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 7.5m(horizontal)
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic
room.
Indoor Units. Ceiling & Floor
45
Model
SIB-200TAY
Power supply
V-ph-Hz
380~415-3-50
Cooling
Capacity
Btu/h
60000
Input
W
5882
EER
2.72
Heating
Indoor fan motor
Model
YSK59-4D
Qty
2
Input
W
89.5/81.5/77.5
Capacitor
uF
2.5uF/450V
Speed(Hi/Mi/Lo)
r/min
1170/1070/995
Indoor coil
Number of rows
3
Tube pitch(a)
×row
pitch(b)
mm
25.4
×22
Fin spacing
mm
1.7
Fin type (code)
Hydrophilic aluminum
Tube outside dia.and type
mm
φ9.5 Inner grooved copper
tube
Coil length
×height×width
mm
1360
×254×66
Number of circuits
5
Indoor air flow(Hi/Mi/Lo)
m
3
/h
2000/1800/1600
Indoor noise level (sound pressure)
dB(A)
50/49/47
Indoor unit
Dimension (W
×H×D)
mm
1670
×240×680
Packing (W
×H×D)
mm
1715x273x760
Net/Gross weight
kg
46/56
Refrigerant type
R410A
Design pressure
MPa
4.2/1.5
Refrigerant
piping
Liquid side/Gas side
mm
12.7/
19
Drainage water pipe diameter
mm
OD
25
Controller
RG36C/BG(C)E
Operation temperature
17-30
Capacity
Btu/h
65000
Input
W
6835
COP
2.78
Содержание SIB-100BAY
Страница 1: ...S13 01 01 13en Light Commercial Air Conditioner R410A ON OFF Service Manual 2013 ...
Страница 6: ...Light Commercial R410A on off S13 01 01 13en 2 2 Outdoor Units General Information 5 ...
Страница 14: ...Light Commercial R410A on off S13 01 01 13en 4 Service Space Indoor Units Four way Cassette Type Compact 13 ...
Страница 48: ...Light Commercial R410A on off S13 01 01 13en 4 Service Space Indoor Units Ceiling Floor 47 ...
Страница 55: ...Light Commercial R410A on off S13 01 01 13en SIB 100TAY SIB 140TAY SIB 200TAY Indoor Units Ceiling Floor 54 ...
Страница 62: ...Light Commercial R410A on off S13 01 01 13en SIB 50TAV SIB 60TAV Indoor Units Ceiling Floor 61 ...
Страница 63: ...Light Commercial R410A on off S13 01 01 13en SIB 100TAY SIB 140TAY SIB 200TAY Indoor Units Ceiling Floor 62 ...
Страница 68: ...Light Commercial R410A on off S13 01 01 13en 3 Dimensions Indoor Units HSP Duct Type 67 ...
Страница 69: ...Light Commercial R410A on off S13 01 01 13en Indoor Units HSP Duct Type 68 ...
Страница 72: ...Light Commercial R410A on off S13 01 01 13en 5 3 SIB 140DAY SIB 200DAY Indoor Units HSP Duct Type 71 ...
Страница 81: ...Light Commercial R410A on off S13 01 01 13en 11 Field Wiring SIB 60DAV Indoor Units HSP Duct Type 80 ...
Страница 82: ...Light Commercial R410A on off S13 01 01 13en SIB 100DAY SIB 140DAY SIB 200DAY Indoor Units HSP Duct Type 81 ...
Страница 91: ...Light Commercial R410A on off S13 01 01 13en 5 Wiring Diagrams SOB 50VA Outdoor Units 90 ...
Страница 92: ...Light Commercial R410A on off S13 01 01 13en SOB 60VA SOB 100YA Outdoor Units 91 ...
Страница 93: ...Light Commercial R410A on off S13 01 01 13en SOB 140YA SOB 200YA Outdoor Units 92 ...
Страница 117: ...Light Commercial R410A on off S13 01 01 13en 6 Wiring Please refer to the Wiring Diagram Installation 117 ...