VM1000B
- 21 -
Chapter 4 Parameter function
“○”
: the parameter can be modified in both standby and operating state
;
“●”
: the parameter can’t be modified in operating state
;
“
◎
”
:the parameter is the actual detected and recorded value which can’t be modified
;
Note: the communication address is hexadecimal.
4.1 Functional parameter
Function
Code
Parameter Name
Setting Range
Default
Property
Address
(HEX)
F0 Group: basic function
F0.00
Motor control mode
0:Sensorless vector control
(
SVC
)
1: V/F control
1
●
0000
F0.01
Command source
selection
0
:
Keypad control
(
LED off
)
1
:
Terminal control
(
LED on
)
2
:
Communication LED (LED blinking
)
0
●
0001
F0.02
UP/DOWN standard
0
:
Operating frequency
1
:
Setting frequency
1
●
0002
F0.03
Setting main frequency
source X
0
:
Digital setting (non-retentive at power
failure)
1
:
Digital setting (retentive at power failure)
2
:
AI1
3
:
AI2
4
:
Reserved
5
:
Reserved
6
:
Multi-speed instructions
7
:
Simple PLC
8
:
PID
9
:
Communication setting
1
○
0003
F0.04
Setting auxiliary
frequency source Y
Same as F0.03(Settings of main frequency
source X)
0
○
0004
F0.05
Range of auxiliary
requency source Y
0
:
Relative to the maximum frequency
1
:
Relative to frequency source X
0
○
0005
F0.06
Percentage range of
auxiliary requency source
Y
0%
~
150%
100%
○
0006
F0.07
Frequency reference
selection
Single-digit: Selection of frequency source
selection
0
○
0007