9
Figure 12
4: If you want to hang on the wall, turn the
DC plug
down until 0 degrees and closed
the desk stand; as shown in Figure 13
Figure 13
Note:
If the power adapter is plugged in,
BL ON
will display in the time area for three
seconds when powered up. Conversely, if the power adapter is not plugged in,
BL OFF
will be displayed.
3.4.2Sensor Operation Verification
The following steps verify proper operation of the sensors prior to installing the sensor
array.
1. Verify proper operation of the rain gauge. Tip the sensor array back and forth several
times. You should hear a “clicking”sound within the rain gauge. Verify the rain reading on
the display console is not reading 0.00. Each “click”represents 0.01in of rainfall.
2. Verify proper operating of the wind speed. Rotate the wind cups manually or with a
constant speed fan. Verify the wind speed is not reading 0.0.
3. Verify proper operation of the indoor and outdoor temperature. Verify the indoor and
outdoor temperature match closely with the console and sensor array in the same location
(about 9.8 ft apart). The sensors should be within 4°F(the accuracy is
±
2
°
F). Allow about
30 minutes for both sensors to stabilize.
4. Verify proper operation of the indoor and outdoor humidity. Verify the indoor and
outdoor humidity match closely with the console and sensor array in the same location