background image

UAIS DEBEG 3400, Electronics Unit

ED3047G142 / 08 (2004-06)

Technical Manual

6  Repair/Maintenance

6.3  Software Update

 t_ue_e07.fm / 21.06.04

60

Connection at the PC/Laptop

The serial cable must be
connected to COM 1 of the PC/
Laptop.

Connection at the Electronics Unit

The cable must be connected to the serial service interface of the computer and to the connector on the
top of the Electronics Unit’s pcb.

Fig. 6-8

Service Interface

6.3.4

Software Update by means of a Laptop

1.

Disconnect the Electronics Unit from the power supply for about 5 s.

2.

Connect the power supply and wait about 2 minutes until the Electronics Unit has been restarted.

3.

Connect the update cable before the update software is started.

4.

Download the update from the SAM-CMIS system (see Section 6.3.1), unzip the file and save the
unzipped directory structure to the hard disk or on a CD ROM or use the Update CD-ROM.

Fig. 6-7

Connection to the Laptop

COM 1

z_ue_0

50.

jpg

z_ue_0

51.

jpg

z_ue

_027.

jpg

Service Interface

5

1

z_ue

_048.

jpg

z_ue

_049.

jpg

Содержание UAIS1900

Страница 1: ...SAILOR UAIS1900 Universal AIS Transponder Technical Manual ...

Страница 2: ...se only is subject to change without notice may contain errors or inaccuracies and represents no commitment whatsoever This agreement is governed by the laws of Denmark Doc No M1900GB0 In this manual the SAILOR UAIS1900 Universal AIS Transponder is referenced as Universal Automatic Identification System UAIS DEBEG 3400 The SAILOR KDU1905 Keyboard Display Unit is referenced as Display and Control U...

Страница 3: ...allation Recommendations 23 3 1 General Recommendations 23 3 1 1 Cables 23 3 1 1 1 Maximum Cable Length 24 3 1 1 2 Cable Sets 25 3 1 2 Electronics Units 25 3 1 3 Antennas 26 3 2 Specific Recommendations 27 3 2 1 Recommendations Concerning AIS Systems 27 3 2 2 Recommendations Concerning the Installation of the Electronics Unit 27 3 2 3 Recommendations Concerning the Installation of the Antennas 27 ...

Страница 4: ...n NACOS xx 3 Systems 50 5 3 4 Configuration with Radar 9xxx 50 5 4 Testing 50 6 Repair Maintenance 51 6 1 Trouble Shooting 51 6 1 1 Hints 51 6 1 2 Trouble Shooting for UAIS DEBEG 3400 connected to a RADARPILOT 1000 52 6 1 2 1 Indication System Fault Message 3617 Displayed on Indicator 52 6 1 2 2 Indication System Fault Message 3616 Displayed on Indicator 56 6 2 Test of the Antenna Performance 56 6...

Страница 5: ... 2 Performance 71 7 2 1 Performance Data of the Electronics Unit 71 7 2 2 Performance Data of the VHF Antenna CLX 2 1 150 170 MHz 72 7 2 3 Performance Data of the GPS Antenna 73 7 3 Dimensions and Weights 73 7 4 Compass Safe Distances 73 8 Fault Code List 75 9 Cabling Documents 81 10 Outline Drawings 99 Notes 105 ...

Страница 6: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual List of Contents t_ue_eIV fm 21 06 04 6 ...

Страница 7: ...AIS TxD 55 Fig 6 6 Suggestion for an update cable 59 Fig 6 8 Service Interface 60 Fig 6 9 Opening of the Electronics Unit housing 63 Fig 6 10 Exchange of the Electronics Module 64 Fig 6 11 Position of the fan 68 Fig 9 1 Cable Diagram 1 6 connection to DCU DEBEG 3401 via Primary Display Port 82 Fig 9 2 Cable Diagram 2 6 connection to RADARPILOT 1000 NACOS xx 4 via Primary Display Port 83 Fig 9 3 Ca...

Страница 8: ...ble Diagram 1 1 Antenna cables longer than 40 m 98 Fig 10 1 UAIS DEBEG 3400 Electronics Unit NG3030G010MB current version of the housing 100 Fig 10 2 UAIS DEBEG 3400 Electronics Unit NG3030G010MB former version of the housing 101 Fig 10 3 AIS GPS antenna 1 2 102 Fig 10 4 AIS GPS antenna 2 2 103 Fig 10 5 AIS VHF antenna 104 ...

Страница 9: ...isplay and Control Unit DEBEG 3401 DSC Digital Selective Call E ECDIS Electronic Chart Display and Information System H HDG Heading L LR Long Range M MAC Medium Access Control MKD Minimum Keyboard and Display MMSI Maritime Mobile Service Identity P PDP Primary Display Port Presentation Interface PP Pilot Port Auxiliary Display Port S SOG Speed Over Ground U UAIS AIS V VDL VHF Data Link VDM Serial ...

Страница 10: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual List of Abbreviations t_ue_eak fm 21 06 04 10 ...

Страница 11: ...ng damage is expressly ruled out regardless of whether the damage is of a direct or indirect nature Unusual shipbuilding shapes additions or superstructures as well as environmental influences can impair the functioning of the equipment We are of course willing to help the customer with optimizing solutions subject to suitable commercial arrangements The customer is responsible for ensuring that S...

Страница 12: ...by a qualified technician The mains must be switched off e g by means of a common isolating switch or a circuit breaker in the ship s supply or the mains cable must be disconnected until setting to work takes place If a synchro is connected to the Analog Interface or Inter face Expander dangerous voltages might be present even although all supplies to the system are switched off Capacitors and tub...

Страница 13: ...0 is equipped with a 12 channel GPS receiver and provides position data according to IEC 61162 Edition 2 so that it is suitable for the use as a position sensor In areas where the VTS stations provide differential correction data via VHF link the UAIS DEBEG 3400 switches auto matically into DGPS mode For further details see Section 4 2 1 Compatibility with Other Systems The UAIS DEBEG 3400 can be ...

Страница 14: ...l gyro is avail able an analog gyro AC gyro or DC stepper can be connected by means of the DEBEG 4901 Gyro Converter Unit VS3037G010 See the Technical Manual of the Gyro Converter Unit for further informa tion Extensions Further DCUs Slave DCUs VHF Antenna VHF Antenna RS422 RS422 24 VDC 24 VDC Position Sensor Position Sensor Gyro Gyro Speedlog bottom track Speedlog bottom track RS422 RS422 RS422 R...

Страница 15: ... Interconnection Box with Analog Interface VHF Antenna VHF Antenna Ship s sensor data Ship s sensor data Ship s sensor data Ship s sensor data Gyro HDT ROT Speedlog bottom track VBW Position Sensor GLL VTG DTM All data are transferred with a repetition rate of 1 Hz IEC 61162 1 except of DTM 0 1 Hz Gyro HDT ROT Speedlog bottom track VBW Position Sensor GLL VTG DTM All data are transferred with a re...

Страница 16: ... Box Interconnection Box with Analog Interface Interconnection Box with Analog Interface VHF Antenna VHF Antenna CHARTPILOT 9320 30 CHARTPILOT 9320 30 RADARPILOT CHARTRADAR MULTIPILOT 1000 RADARPILOT CHARTRADAR MULTIPILOT 1000 RADARPILOT CHARTRADAR MULTIPILOT 1000 RADARPILOT CHARTRADAR MULTIPILOT 1000 Ethernet LAN Ethernet LAN Ship s sensor data Ship s sensor data Ship s sensor data Ship s sensor ...

Страница 17: ...ams GLL VTG HDT ROT VBW if bottom track log is available Extensions Further DCUs VHF Antenna VHF Antenna CHARTPILOT 93xx 2 CHARTPILOT 93xx 2 Ethernet LAN Ethernet LAN Ship s sensor data Ship s sensor data Ship s sensor data Ship s sensor data RS422 RS422 RS422 RS422 UART1 UART1 UAIS Electronics Unit UAIS Electronics Unit Navigation Interface Navigation Interface GPS Antenna GPS Antenna Sensor Inpu...

Страница 18: ...ce the output interfaces of the Ship s Interface must be configured as follows Select IEC 61162 1 edition 2 2000 NMEA 2 3 as driver Set a repetition interval of 1 s for the following telegrams GLL VTG HDT ROT VBW if bottom track log is available VHF Antenna VHF Antenna CHARTPILOT 93xx 1 CHARTPILOT 93xx 1 MULTIPILOT 910x MULTIPILOT 910x Radar 9xxx Radar 9xxx UAIS Electronics Unit UAIS Electronics U...

Страница 19: ...rfaces of the Ship s Interface must be configured as follows Select IEC 61162 1 edition 2 2000 NMEA 2 3 as driver Set a repetition interval of 1 s for the following telegrams GLL VTG HDT ROT VBW if bottom track log is available VHF Antenna VHF Antenna RADARPILOT 1000 RADARPILOT 1000 RADAR 9xxx RADAR 9xxx UAIS Electronics Unit UAIS Electronics Unit GPS Antenna GPS Antenna SAM SAM Ship s sensor data...

Страница 20: ...om Ship s Interface the output interfaces of the Ship s Interface must be configured as follows Select IEC 61162 1 edition 2 2000 NMEA 2 3 as driver Set a repetition interval of 1 s for the following telegrams GLL VTG HDT ROT VBW if bottom track log is available VHF Antenna VHF Antenna Radar 9xxx Radar 9xxx Radar 9xxx Radar 9xxx UAIS DEBEG 3400 UAIS DEBEG 3400 GPS Antenna GPS Antenna SAM SAM SAM S...

Страница 21: ...Unit The aluminium housing contains a single Electronics Unit which consists of the controller the interfaces the VHF transmitter receiver and the GPS receiver The former version of the housing has five cable glands for ship s cables and three coaxial connectors for the connection of Ethernet LAN GPS and VHF antennas The current version has cable inlets instead of the cable glands z_ue_012 tif z_u...

Страница 22: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 2 Overview 2 9 DEBEG 3400 Electronics Unit t_ue_e02 fm 21 06 04 22 ...

Страница 23: ...s they are either fixed to the unit or can be seen from the outline drawings BZ or MB All cables should be kept as short as possible especially coaxial cables to minimize attenuation of the signal All connectors installed outdoors e g on coaxial cables should be waterproof by design to protect against water penetration into the cable Coaxial cables should be installed in separate signal cable chan...

Страница 24: ...12 50 is 80 m See Section 9 Cabli ng Document s Coaxial Cable for the GPS Antenna The length of this cable is defined by the cable sets Prefabricated cables with a length of 20 30 or 40 m can be delivered If a length of more than 40 m is needed the cable LCF 12 50 of the VHF antenna must be used in combi nation with TNC N plug adapters See Section 9 Cabl ing Document s Ethernet LAN The Ethernet LA...

Страница 25: ...installation of the unit in a confined cabinet Furthermore the distance from the ceiling and the floor or from a unit situated underneath must be at least 300 mm For service purposes a power socket AC 220 230 V and adequate lighting are necessary in the vicinity of each Electronics Unit In the area of the wheel house the distance of each Electronics Unit from the magnetic standard compass or the m...

Страница 26: ...crews are tightened because such twisting would impair mechanical functions Any unevenness should be compensated for by means of spacing washers The grounding screws of the units must be connected to the body of the ship ground the wire used should have a cross sectional area of at least 6 mm Aboard fibreglass GRP vessels a grounding network with a high conductance taking into consideration the wo...

Страница 27: ...this document 3 2 2 Recommendations Concerning the Installation of the Electronics Unit The Electronics Unit should be mounted on a vertical bulkhead A distance of at least 300 mm from other devices must be ensured around the housing for sufficient air circulation See also Section 10 Outli ne Drawings 3 2 3 Recommendations Concerning the Installation of the Antennas Fig 3 2 Minimum distances for G...

Страница 28: ... objective for the VHF antenna is that it should see the horizon freely through 360 The VHF antenna should be installed safely away from interfering high power energy sources such as the radar scanner and other transmitting radio antennas preferably at least 3 m away from and out of the transmitting beam Ideally there should not be more than one antenna on the same level The AIS VHF antenna should...

Страница 29: ...all diameter obstructions such as masts and booms do not seriously degrade signal reception but such objects should not eclipse more than a few degrees of any given bearing Locate the antenna at least 3 m away from and out of the transmitting beam of high power transmitters S Band radar and or Inmarsat systems This includes the ship s own AIS VHF antenna GPS Antenna GPS Antenna GPS Satellites GPS ...

Страница 30: ...m is required The AIS requires status information to check the data integrity All NMEA versions lower than 2 01 are not allowed for the use with AIS To verify that the NMEA version is 2 01 or higher check the settings of the GPS sensor Data Telegrams For all NMEA versions lower than 2 3 the GGA message must be transmitted Only the GGA message transmits the information that the differential mode is...

Страница 31: ...performed The software version must be 096 or higher Older versions do not comply to IEC 61162 1 edition 2 2000 NMEA 2 3 In these versions source and status of the position data is not indicated Such versions must not be used with an AIS If the AIS is installed in combination with a MULTIPILOT 91x0 or a CHARTPILOT 9320 9330 the complete navigation system has to be updated to software version 097A ...

Страница 32: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 3 Installation Recommendations 3 2 Specific Recommendations t_ue_e03 fm 21 06 04 32 ...

Страница 33: ... ship s data the ship s sensor data and the position data from external or internal GPS receiver are transmitted via VHF In the opposite direction the corresponding data of other ships equipped with AIS systems are received by means of the VHF receiver These data are processed and sent to the navigation system via the primary display port or the Ethernet LAN The functions of the pilot port corresp...

Страница 34: ...ver has a limited range By means of the connection of a long range commu nication system such as a satellite communication system to the long range port this limitation can be eliminated In this way the AIS can be called to send the ship s data The requested data are sent via the long range port and the long range communication system to the questioner The operator can decide whether a long range ...

Страница 35: ...e network is a 10 Mbit network The BNC T plugs must be connected directly into the Ethernet Module It is not admissible to connect the T plug and the network adapter by means of a coaxial cable Proper termination with a 50 Ω BNC termination plug at both ends of the Ethernet line is very important It is not permissible to use cable with a characteristic impedance different from 50 Ω If no cable is ...

Страница 36: ...eripheral Components Motherboard pcb Processors for the digital signal processing 3 interfaces IEC 61162 1 2 for ship s sensor data input Long range port IEC 61162 2 Primary display port IEC 61162 2 and pilot port IEC 61162 2 Ethernet interface Built in Integrity Test BIIT Power supply input 24 VDC 10 30 Electronics Unit Interfaces and Displays Antennas Mainboard AIS DSC BIIT Power Supply AIS A Re...

Страница 37: ...f VDM messages received by VHF and VDO messages sent by VHF The static ship s data such as ship s name callsign and destination are input by means of the VSD and SSD messages See IEC 61993 2 for valid messages This port is connected to the SAM Electronics system for example Pilot Port RS422 IEC 61162 2 38400 Baud 4 Output TxD 3 Output TxD 2 Input RxD 1 Input RxD See Primary Display Port Additional...

Страница 38: ...r is required In addition the optional checksum is required AIS requires status information to check the data integrity All NMEA versions below 2 01 are not allowed for the use with AIS Data Telegrams For all NMEA versions below 2 3 corresponds to IEC 61162 1 edition 2 2000 the GGA message must be transmitted Only the GGA message transmits the information that differential mode is activated This i...

Страница 39: ...ix data GLL Geographic position latitude longitude RMC Recommended minimum specific GNSS data Speed over Ground SOG VBW Dual ground water speed VTG Course over ground and ground speed RMC Recommended minimum specific GNSS data Course over Ground COG RMC Recommended minimum specific GNSS data VTG Course over ground and ground speed Heading HDT Heading true RAIM indicator GBS GNSS satellite fault de...

Страница 40: ...ternal AIS position sensor relative to the ship s system position AISPOF AIS offset relative to system position Any telegram which is sent by long range function must be acknowledged by means of AISLRA AISLRA AIS long range acknowledgement Queries Query ACA Query PSAEAISTXD Query PSAEAISLFS Query PSAEAISVER Q Query for ACA data Query for transmitter status Query for Electronics Unit log file Query...

Страница 41: ...ogation Type of request Geographic area request AIS unit request LRI Long range interrogation Long range function identification Requester MMSI and Name Request for Ship s name call sign IMO number Date and time of message composition Position Course over ground Speed over ground Destination and ETA Draught Ship Cargo Ship s length breadth and type Number of persons on board LRF Long range functio...

Страница 42: ... e g WG84 DTM Datum reference Global positioning system GPS fix data UTC hhmmss ss Latitude N S data and N or S or empty fields Longitude E W data and E or W or empty fields GPS quality 0 fix not available 1 GPS SPS mode 2 Differential mode 3 GPS PSS mode 4 Real Time Kinematic 5 Float RTK 6 Estimated mode 7 Manual input mode 8 Simulator mode Number of satellites 00 12 Horizontal dilution x x data ...

Страница 43: ...f reference station x x data or empty field GNS Global positioning system Recommended minimum specific GNSS data UTC hhmmss ss Status V or A Latitude N S IIII II a Longitude E W YYYYY YY a Speed over ground knots x x Course over ground degrees true x x Date dd mm yy xxxxxx Magnetic variation degrees E W data and E or W or empty fields Mode indicator A Autonomous mode D Differential mode E Estimate...

Страница 44: ... The interfaces comply with IEC 61162 1 2000 2nd Edition and IEC 61162 2 1998 The designation in this manual corresponds to the designation Line A of IEC 61162 1 2 The designation in this manual corresponds to the designation Line B of IEC 61162 1 2 Output Current and Input Load Maximum output current 25 mA at 3 0 V Listener receiver load 0 8 mA at 0 3 V differential voltage 1 25 mA at 2 0 V diffe...

Страница 45: ...7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 1 2 3 4 J1 AIS Electronics Unit Gyro Interface 9401 DCU 3401 Pilot Plug 24 V 0 V BN GY PK WH WH GN GN YE YE BN GY PK S3 24 V 0 V Alarm break Alarm center Alarm make R S T Common RS422 1 6 9 5 4 1 24 V DC IN Alarm S2 Sensor Input Prim Displ P Pilot Port S1 8 9 10 11 7 6 5 4 3 2 1 8 12 9 13 10 14 11 15 7 6 5 4 3 2 1 TB Terminals yard supp...

Страница 46: ...enna with 50 Ω impedance For the technical data see Section 7 for installation instructions see Section 3 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 1 2 3 4 AIS Electronics Unit DCU 3401 Pilot Plug 24 V 0 V BN GY PK WH WH GN GN YE YE BN GY PK S3 24 V 0 V Alarm break Alarm center Alarm make RS422 1 6 9 5 4 1 24 V DC IN Alarm S2 Sensor Input Prim Displ P Pilot Port S1 8 12 9 13 ...

Страница 47: ...ment front view pins A Pilot Plug Connector can be ordered with the order No 390000847 For passages of the Panama Channel a 125 V AC supply NEMA 5 15 must be available for the pilot For ships with 230 V mains the transformer 271257903 can be ordered from SAM Electronics z_ue_030 eps 1 3 2 4 5 6 7 8 9 Pin Function Color of wire Connection at AIS Electronics Unit 1 TxD Output white Connector 2 termi...

Страница 48: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 4 Functional Description 4 3 Description of the Components t_ue_e04 fm 21 06 04 48 ...

Страница 49: ...update see Section 6 3 on page 57 5 3 Configuration No adjustments have to be performed on the antennas These components are ready for use The AIS Electronics Unit must be parameterized via a connected RADARPILOT 1000 CHARTPILOT 9320 30 MULTIPILOT 1000 or the Display and Control Unit DEBEG 3401 For information in detail see the corresponding Technical Manuals and the On line Help of these systems ...

Страница 50: ...tion in detail see the Service Manual of the Radar 9xxx Electronics Unit 5 4 Testing The Electronics Unit has neither operating elements nor a display Correct functioning cannot be made visible directly To test the interfaces of the ship s sensor inputs and the interface to the display unit which can be the RADARPILOT 1000 CHARTPILOT 9330 MULTIPILOT 1000 or the Display and Control Unit DEBEG 3401 ...

Страница 51: ...ctly the same way Exceptions are explained in this manual 6 1 Trouble Shooting 6 1 1 Hints In the case of problems during setting to work the cabling should be checked again All components must be supplied with power To get more information about the problem read the system fault messages on the screen and refer to Section 8 on page 75 Watchdog In various error conditions the internal watchdog of ...

Страница 52: ...e the Technical Manual of the RADARPILOT 1000 for further information If the system fault message is still existing the communication on the Primary Display Port must be checked Proceed as follows Test of the RADARPILOT CHARTRADAR MULTIPILOT 1000 Output 1 Power Down the system 2 Connect the AIS output TB14 and TB15 of the Analog Interface additionally to an indicator serial interface TB1 of the ra...

Страница 53: ...mmunication on the interface the Analog Interface is defective or has a wrong software version The software version must be F or newer To check the software version use the Telemonitoring Data menu of the System Main tenance manager The line for the Analog Interface must look as follows SIR10T GE3044P207 F or the configuration of the radar is faulty See the Technical Manual of the radar for furthe...

Страница 54: ...follows Path Configure Radar Indicator Indicator x Serial Interfaces Serial I O x Parameters Driver set to NMEA183 IEC 61162 1 2 Baud Rate set to 38400 Wind set to Connected if the interface has been used for a ship s sensor with NMEA183 IEC 61162 1 2 protocol beforehand it is not necessary to modify this parameter 4 The Serial I O Monitor must be started Path Service Indicator Serial I O Monitor ...

Страница 55: ...VDM 1 1 B 1000O B038H L vBOL Cr39V08Bg 0 65 AIVDO 1 1 139K6D7037H L FBOL kr39 0000 0 52 AIVDO 1 1 139K6D7037H L LBOL9kr39b0000 0 5A AIVDO 1 1 B 139K6D7037H L LBOL9kr39b0D01 0 6D AIVDO 1 1 139K6D7037H LALBOL7Sr39d0000 0 14 AIVDO 1 1 139K6D7037H LC BOL5Sr39f0000 0 66 AIVDO 1 1 139K6D7038H LEFBOL3Cr39h0000 0 0D AIVDO 1 1 139K6D7038H LGLBOKvkr39j0000 0 6D AIVDM 1 1 A 1000O B038H LE2BOL3kr39h0HF7 0 62 ...

Страница 56: ...e the Technical Manual of the RADARPILOT 1000 for further information 3 Check the software version of the Analog Interface The software version must be F or newer To check the software version use the Telemonitoring Data menu of the System Maintenance manager The line for the Analog Interface must look as follows SIR10T GE3044P207 F 6 2 Test of the Antenna Performance With newer versions of the El...

Страница 57: ... AIS system can be downloaded from the internet It is also possible to order update kits and update CDs Preconditions Internet Explorer 5 5 with Virtual Machine or newer Cookies must be accepted To gain access Enter the address http www sam cmis de Type customer in the field Username no capitals small letters only Type download in the field Password no capitals small letters only To open the direc...

Страница 58: ...EBEG 3400 with RADAR 9x00 and MULTIPILOT 910x Radar Mode Press the Menu button Select Utilities Self Check Version Use the CANCEL MORE button to toggle through the pages until the AIS page is reached UAIS DEBEG 3400 with MULTIPILOT 910x ECDIS Mode Open the tree structure by clicking the Tree button Click on System Maintenance Version to display the software versions of the MULTIPILOT and all conne...

Страница 59: ...6 Suggestion for an update cable PC COM port Sub D 9p female Electronics Unit service interface Signal Pin Pin Signal RxD 2 1 TxD GND 5 2 GND TxD 3 3 RxD RTS 7 4 CTS CTS 8 5 RTS Fig 6 5 Premanufactured update cable z_ue_031 jpg Pin1 z_ue_028 jpg Index toes in direction of the cable WIre 1 Flat cable 10 wires Connect the 10 pole connector to the flat cable as shown Only the wires 1 3 5 7 9 are used...

Страница 60: ... 6 8 Service Interface 6 3 4 Software Update by means of a Laptop 1 Disconnect the Electronics Unit from the power supply for about 5 s 2 Connect the power supply and wait about 2 minutes until the Electronics Unit has been restarted 3 Connect the update cable before the update software is started 4 Download the update from the SAM CMIS system see Section 6 3 1 unzip the file and save the unzipped...

Страница 61: ...o start the software Type aisupdate exe on the command line to start the program Windows Explorer Open the Windows Explorer and select the drive with the update directory Select the following path by clicking twice on the directory names AIS Electronics Unit BuildNNN_YYYY_MM_DD root Start the program aisupdate exe by clicking twice on the corresponding icon 6 Click the Start Update button If a fai...

Страница 62: ...ed on the Flash ROM If the power supply was interrupted during the update process it may occur in seldom cases that the electronics unit is not restarting again In this case it may necessary to exchange the Disk On Chip memory module 6 3 5 Software Update by means of a CHARTPILOT or MULTIPILOT 91x0 If a CHARTPILOT or MULTIPILOT 91x0 is connected the AIS Electronics Unit must be connected to the LA...

Страница 63: ... 06 04 63 6 4 Opening the Housing Fig 6 9 Opening of the Electronics Unit housing Undo the four screws in the cover The screws cannot be removed Disconnect the grounding cable from the cover To close the housing proceed in the reverse order 6 5 Fuses Electronics Unit The Electronics Unit contains no fuses z_ue_021 tif z_ue_038 jpg ...

Страница 64: ...ct them 5 Unscrew the screws of the mounting plate Fig 6 10 Exchange of the Electronics Module 6 Former version of the housing lift the Module carefully out of the housing Current version of the housing remove the fan and lift the module at the side marked with A or untighten the clamps at the cable inlets and lift the module at the side marked with A 7 To mount the new Module proceed in the rever...

Страница 65: ...n to the air flow 3 Check the correct functioning of the fan and close the housing 6 6 3 Internal Fan For Ser No 0019230001 to 0019233000 the old fan should be exchanged in all cases For all other Ser No the fan must be replaced only if it is defective Units with a replaced fan must be marked by a label 1 Open the housing of the Electronics Unit as described in Section 6 4 2 If necessary remove th...

Страница 66: ... 66 4 Remove four screws on top of the frame s side wall with the fan 5 Cant the sidewall to the outside Remove the three screws of the fan and disconnect the connector to exchange it z_ue_033jpg z_ue_474jpg Connector Old Fan Brand SUNON Breadth 30mm Width 30mm Depth 6mm New Fan Brand SEPA Breadth 30mm Width 30mm Depth 12mm z_ue_054jpg z_ue_055jpg ...

Страница 67: ...together during mounting the upper pcb 7 Verify the function of the fan after power on 8 Put the enclosed label outside on the housing on a good visible position Fill in date and time 9 Verify the proper function of the system make sure that AIS targets and sensor data will be displayed on the connected display system 6 6 4 Antennas If one of the antennas is defective it must be exchanged See the ...

Страница 68: ...oise is indicating damaged bearings Fig 6 11 Position of the fan Housing Fan If the housing has a fan current version of the housing it is recommended to check the fan and to exchange the filter pad every three month This can be performed by the operator or during service work It must be checked whether the fan is running noticeable airflow and whether noise is indicating damaged bearings To excha...

Страница 69: ...pare part and new versions of components are added to this manual as soon as possible Description Order Number VHF Antenna CXL 2 1 M TNC 271259204 GPS Antenna 1330 FP 271257889 Set of antenna cables internal 271178666 UAIS DEBEG 3400 Electronics Unit NG3030G010 300005451 Electronics Unit module incl antenna cables 271257904 Disk on Chip 271178730 Filter Pad for housing fan current version of the h...

Страница 70: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 6 Repair Maintenance 6 8 Spare Parts t_ue_e07 fm 21 06 04 70 ...

Страница 71: ... of the UAIS DEBEG 3400 comply with IEC 61162 1 2000 2nd Edition and IEC 61162 2 1998 7 2 Performance 7 2 1 Performance Data of the Electronics Unit General Housing Rev B IP66 Rev C IP22 Operating temperature 15 55 C DIN EN 60945 Humidity Max 95 at 40 C DIN EN 60945 DC voltage supply 24 VDC 10 30 21 6 31 2 V DIN EN 60945 DC current consumption Typ 1 2 A at 24 V max 2 5 A momentarily during transmi...

Страница 72: ...nna type λ coaxial broad band Frequency 150 170 MHz Impedance Nom 50 Ω Polarization Vertical Gain 2 dBi 0 dBd Bandwith 20 MHz SWR 1 5 Max power 150 W Connector TNC female Wind load 21 8 at 150 km h Material Whip Glassfibre Colour Marine white Total length Approx 1 2 m Weight Approx 340 g Mounting 1 threaded mast tube For the outline drawings see Section 10 z_ue_407 pdf z_ue_408 pdf z_ue_409 pdf ...

Страница 73: ...Gain 4 5 dBiC nom Low Noise Amplifier Frequency 1575 42 10 MHz GPS L1 Impedance 50 Ω Nominal output VSWR 2 0 1 Max gain 26 5 3 dB DC voltage supply 5 26 VDC through connector DC current consumption 25 mA typ 40 mA max Filtering Dual ceramic filter 7 3 Dimensions and Weights For dimensions and weights see the technical drawings The drawings are shown in Section 10 7 4 Compass Safe Distances Standar...

Страница 74: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 7 Technical Data 7 4 Compass Safe Distances t_ue_e08 fm 21 06 04 74 ...

Страница 75: ... The Electronics Unit continues operation Remedy Check of the antenna and the antenna cabling 75 Ω cable instead of 50 Ω cable 003 AIS Rx channel 1 malfunction Rx channel 1 malfunction AIS RX CH1 FAULT Generated by AIS Electronics Unit Cause Source Internal error Reaction The Electronics Unit stops the transmission on the affected channel Remedy The Electronics Unit must be exchanged 004 AIS Rx ch...

Страница 76: ... Cause Source No data from external sensor and from internal position sensor Reaction The Electronics Unit continues operation Remedy The telegrams VBW VTG RMC can not be received Check the sensor and the cabling Check if the system that transmits the data is working RADARPILOT 1000 Check the baud rate settings of the sensor inputs 030 AIS No valid COG informa tion No valid COG information AIS NO ...

Страница 77: ...nues operation without internal GPS data and without direct GPS time synchroni zation Remedy The Electronics Unit must be exchanged 100 0100 Generated by DCU Internal Test Error RAM Check 101 0101 Generated by DCU Internal Test Error ROM Check 102 0102 Generated by DCU Internal Test Error EEPROM number 103 0103 Generated by DCU Internal Test MC system error watchdog 104 Target over flow Generated ...

Страница 78: ...See the Operating Instructions 203 Long range interrogation Generated by DCU See the Operating Instructions 0204 AIS offline AIS offline AIS OFFLINE Generated by AIS Electronics Unit Cause Source No connection between DCU and Elec tronics Unit no valid IEC 61162 data or reset caused by the watchdog Reaction The Electronics Unit continues operation Remedy The cabling must be checked It might be pos...

Страница 79: ...ntinues operation Remedy The transmitter must be switched on see the Operating Instructions of the DCU or the MMSI number must be configured If it has not been configured before hand it is set to 0 and no data is transmitted Remedy Check other error messages to find the reason for the alarm If there are no further messages restart the Electronics Unit by disconnecting the mains supply SET GYRO req...

Страница 80: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 8 Fault Code List t_ue_e09 fm 21 06 04 80 ...

Страница 81: ...eans of separate flexible cables to the main structure of the housing It is important to connect this ground cable after parts have been dismounted or exchanged Title Page C a bl e D i a gram 1 6 co nn ect i on t o D C U D E B E G 34 01 vi a Pr i m a r y D i spl ay Po r t 82 C a bl e D i a gram 2 6 co nn ect i on t o R A DA R P I LOT 10 00 N AC O S x x 4 vi a Pr i m a r y D is pl ay Po r t 83 C a ...

Страница 82: ...S DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 82 Fig 9 1 Cable Diagram 1 6 connection to DCU DEBEG 3401 via Primary Display Port z_ue_501 pdf ...

Страница 83: ...G 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 83 Fig 9 2 Cable Diagram 2 6 connection to RADARPILOT 1000 NACOS xx 4 via Primary Display Port z_ue_502 pdf ...

Страница 84: ...G 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 84 Fig 9 3 Cable Diagram 3 6 connection to CHARTPILOT NACOS xx4 RADAR MULTIPILOT 1000 via LAN z_ue_503 pdf ...

Страница 85: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 85 Fig 9 4 Cable Diagram 4 6 connection to CHARTPILOT stand alone z_ue_504 pdf ...

Страница 86: ...G 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 86 Fig 9 5 Cable Diagram 5 6 connection to Radar 9xxx via Radar 9xxx AIS Interface NACOS xx 3 z_ue_505 pdf ...

Страница 87: ...EBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 87 Fig 9 6 Cable Diagram 6 6 connection to DCU DEBEG 3401 and Gyro Converter DEBEG 4901 z_ue_506 pdf ...

Страница 88: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 88 Fig 9 7 Connection Diagram 1 10 connection to DCU DEGEG 3401 z_ue_507 pdf ...

Страница 89: ... 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 89 Fig 9 8 Connection Diagram 2 10 DCU connectors alarm input Primary Display Port power supply z_ue_508 pdf ...

Страница 90: ...00 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 90 Fig 9 9 Connection Diagram 3 10 connection to NACOS xx 4 RADAR MULTIPILOT 1000 via Prim Displ Port z_ue_509 pdf ...

Страница 91: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 91 Fig 9 10 Connection Diagram 4 10 terminals at the Analog Interface z_ue_510 pdf ...

Страница 92: ... 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 92 Fig 9 11 Connection Diagram 5 10 connection to CHARTPILOT NACOS RADAR MULTIPILOT 1000 via LAN z_ue_511 pdf ...

Страница 93: ...IS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 93 Fig 9 12 Connection Diagram 6 10 connection to CHARTPILOT stand alone systems z_ue_512 pdf ...

Страница 94: ...400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 94 Fig 9 13 Connection Diagram 7 10 connection to Radar 9xxx via Radar 9xxx AIS Interface NACOS xx 3 z_ue_513 pdf ...

Страница 95: ... DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 95 Fig 9 14 Connection Diagram 8 10 terminals at the Gyro Converter Unit DEBEG 4901 z_ue_514 pdf ...

Страница 96: ...400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 96 Fig 9 15 Connection Diagram 9 10 connection to DCU DEBEG 3401 and Gyro Converter Unit DEBEG 4901 z_ue_515 pdf ...

Страница 97: ...AIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 97 Fig 9 16 Connection Diagram 10 10 terminals of the Radar 9xxx AIS Interface z_ue_516 pdf ...

Страница 98: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 9 Cabling Documents t_ue_e11 fm 21 06 04 98 Fig 9 17 Cable Diagram 1 1 Antenna cables longer than 40 m z_ue_517 pdf ...

Страница 99: ... Title Page UA I S D E B E G 3 40 0 E l e ct r o n i c s U ni t N G 3 0 3 0 G 0 10M B cur r en t ver sio n o f th e h ou sing 100 UA I S D E B E G 3 40 0 E l e ct r o n i c s U ni t N G 3 0 3 0 G 0 10M B for m er ver sion of th e h ous ing 101 A I S G P S a nt e n n a 1 2 102 A I S G P S a nt e n n a 2 2 103 A I S V H F a nt e n na 104 ...

Страница 100: ...BEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 10 Outline Drawings t_ue_e12 fm 21 06 04 100 Fig 10 1 UAIS DEBEG 3400 Electronics Unit NG3030G010MB current version of the housing z_ue_406 pdf ...

Страница 101: ...0 Electronics Unit ED3047G142 08 2004 06 Technical Manual 10 Outline Drawings t_ue_e12 fm 21 06 04 101 Fig 10 2 UAIS DEBEG 3400 Electronics Unit NG3030G010MB former version of the housing SAM Electronics z_ue_401 pdf ...

Страница 102: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 10 Outline Drawings t_ue_e12 fm 21 06 04 102 Fig 10 3 AIS GPS antenna 1 2 All dimensions are indicated as inches z_ue_402 pdf ...

Страница 103: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 10 Outline Drawings t_ue_e12 fm 21 06 04 103 Fig 10 4 AIS GPS antenna 2 2 z_ue_403 pdf ...

Страница 104: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual 10 Outline Drawings t_ue_e12 fm 21 06 04 104 Fig 10 5 AIS VHF antenna z_ue_404 pdf ...

Страница 105: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual Notes t_ue_eno fm 21 06 04 105 Notes Space for your notes ...

Страница 106: ...UAIS DEBEG 3400 Electronics Unit ED3047G142 08 2004 06 Technical Manual Notes t_ue_eno fm 21 06 04 106 ...

Страница 107: ......

Страница 108: ......

Отзывы: