background image

4

Installation

RT4800/01

2

Installation

Mounting possibilities, dimensions and drilling plan.

2.1

Mounting Possibilities

Transceiver Unit
The transceiver unit is available in both a one- and a two-aerial version.
A one-aerial DSC transceiver can be converted into a two-aerial version (contact your dealer).
The drawing below shows a two-aerial transceiver unit:

35342

222.00

136.00

100.00

56.50

198.00

242.00

77.50

14.50

4 x ø4.00

OPTION

SPARC-BUS

Weight:
Transceiver Unit

1.3 kg

WARNING:
Only use original screws; otherwise you risk short-circuiting the battery ground to the ship ground.

9949

Содержание A1 Basic VHF

Страница 1: ...SAILOR A1 VHF DSC Basic VHF Installation Manual ...

Страница 2: ...rements within the concept of GMDSS as to operation of equipment and basic understanding of the systems is an extremely important factor for the overall success ful implementation of GMDSS As a unique initiative for GMDSS solutions we can supply a complete software training programme for on board training to be used as preparation in order to fulfil the GMDSS requirements for obtaining the General...

Страница 3: ...ation 4 2 1 Mounting Possibilities 4 2 2 Power Supply 5 2 3 Aerial 5 2 3 1 Placing the Aerial s 6 2 4 Options Connector Box H4992 7 2 5 Cable Length 8 2 5 1 Power Cable 8 2 6 Electrical Connections 8 2 6 1 Power Connectors 8 2 7 Compass Safety Distance 8 9949 ...

Страница 4: ...y range 150 8 MHz 163 6 MHz Operating modes Simplex Semi duplex Modulation G3EJN for telephony receiver G2B for DSC signaling Frequency stability 10 ppm opt 5ppm Aerial connectors Standard 50 ohm female SO239 Temperature range 15 C to 55 C Supply voltage 13 2 VDC Nominal Supply range 10 8 VDC to 15 6 VDC Supply current Stand by 0 14 A Transmitter on 1 5 A Low power Transmitter on 5 A High power Tr...

Страница 5: ...ion Below 0 25µW Cabinet radiation Below 0 25µW AF response 6dB octave Distortion Below 5 Signal noise ratio Better than 40dB DSC Facilities DSC operation According to Rec ITU R M 541 6 and Rec ITU R M 689 2 DSC protocol According to Rec ITU R M 493 7 class D Navigator interface NMEA 0183 GGA GLL ZDA NMEA Input current 8mA type Symbol error rate below 1 10 2 at 119 dBm or 0 25µV p d Modulation 170...

Страница 6: ...wo aerial version A one aerial DSC transceiver can be converted into a two aerial version contact your dealer The drawing below shows a two aerial transceiver unit 35342 222 00 136 00 100 00 56 50 198 00 242 00 77 50 14 50 4 x ø4 00 OPTION SPARC BUS Weight Transceiver Unit 1 3 kg WARNING Only use original screws otherwise you risk short circuiting the battery ground to the ship ground 9949 ...

Страница 7: ...t to 12 Volt 24 Volt 35344C Battery 24 Volt 220 Volt 12 Volt 24 Volt to 220 Volt 24 Volt to Fuse The fuse is a standard 10A mini car fuse There is a spare fuse in the power cable connector 2 3 Aerial The transceiver without DSC requires one aerial The transceiver with DSC is available in both a one and a two aerial version All common 50Ω aerials covering the used frequency range with a reasonable ...

Страница 8: ...ounted in a place that is as high and clear as possible like the primary aerials in the illustration below The horizontal distance to metal parts must be at least 1m When using two aerials the primary aerial must be placed at a higher level than the channel 70 aerial 9949 ...

Страница 9: ...cted directly to the transceiver by means of a 15 pole high density D sub in the same pins as those mentioned above Make sure to use the 15 to 15 pole adaptor between the transceiver and the 15 pole high density D sub The two parts part no 78 775 are supplied with the radio 9915 Transceiver unit Twisted Option box X2 Name pair X1 X2 pin 1 DSC_ALARM_ON 1 pin 2 NMEA_OUT 1 1 Optional pin 3 NMEA_OUT 1...

Страница 10: ...voltage at the cable end at N420 should not be less than 18 volt 35355A 10 3 2 1 Spare 10A fuse Pin no Name Colour Pin 1 SUPPLY_ON Blue Pin 2 BAT Red Pin 3 BAT Black NB The blue wire is only to be used in connection with N420 2 6 Electrical Connections 2 6 1 Power Connectors Power connector Transceiver unit Name Battery N420 pin 1 SUPPLY_ON NC SUPPLY_ON pin 2 Battery 12VDC 12V pin 3 Battery 0VDC 0...