Chapter 3: Connectors & controls
Cabling
17
33333
Connector
s & c
on
tr
ols
3.2 Cabling
Before using the Control Panel for the first time, check that all cables are
correctly wired and fastened.
All cables attached to the Control Panel must be shielded.
•
The shield of the Ethernet cable must be connected to ship ground or an
Ethernet switch to which the Control Panel is connected.
•
In the DC power cable the shield of the cable must be connected to ship
ground at the power supply.
3.2.1 Cable requirements
3.2.2 Grounding
The ground stud is located at the rear side of the
Control Panel. To connect the Control Panel to ship
ground, do as follows:
1. Connect a ground cable of shortest possible length
and minimum 4 mm
2
cross section to the Ground
stud and fasten it with the wing nut.
2. Connect the other end of the cable to ship ground.
Cable
Description
Power cable
Included in the delivery.
Length: 2.5 m with AWG 16 wires and a custom
connector at one end. If you are going to use another
cable or extend the supplied cable, make sure the cables
are dimensioned correctly.
Ethernet cable
Shielded Cat. 5E or higher (STP or FTP). The maximum
length is 100 m.
Ground stud
ControlPanel.book Page 17 Thursday, January 3, 2013 12:28 PM
Содержание 6004
Страница 1: ...SAILOR 6004 Control Panel INSTALLATION MANUAL ...
Страница 2: ......
Страница 34: ...Appendix A Technical specifications 26 ControlPanel book Page 26 Thursday January 3 2013 12 28 PM ...
Страница 39: ......
Страница 40: ...98 136644 A info thrane com www thrane com ...