12
5
1 If the condensing unit is installed in a location that has an open airflow, the condensing unit
should be installed in a direction such that airflow out from the condensing unit is perpendicular to
the open air flow direction.
Open Air
Open Air
Air flow out
2
3
Fancoil unit
Condensing unit
Radius 5 cm.
Oil trap
( To condensing )
Space should be left around the condensing unit at least according to the figure for ease of installation,
service and ventilation.
4
Do not incline the condensing unit by more than 45 degrees.
5
Install the condensing unit on a rigid base.
6
Fasten the condensing unit to the base by using the nuts provided.
7
In the case of hanging the condensing, unit it should be hung on a rigid wall area and right angle steel
8
cm. thick should be used for the holder.
Put the rubber
under the nut.
Rigid wall
by using screws.
Right angle steel thick 4 cm.
Fasten right angle steel
4
If installed in a high temperature or humid area, the thickness of the pipe’s insulator should
be increased to 1/2” to protect the condensing water in the refrigerant tube.
If the condensing unit is installed higher than the indoor unit, an oil trap should be made as
show in picture
Water will drop
from indoor
unit.
INCORREC
T
End of drain pipe
is sunk in water.
3.00
cm.
Space is less
than 3.00 cm.
INCORREC
T
1. If necessary, the drain hose can be extended the drain pipe by connecting as following.
Pass the drain hose through the hole in the wall, making sure that the slop e downwards.
Pass drain hose under the refrigerant piping, taking care to keep the drain hose tight.
2.
3.