Saia Burgess Controls PCD2.F2100 Скачать руководство пользователя страница 1

Document 27-649 │ Version ENG02 │ 2018-08-15

Manual 

PCD2.F2xxx  

serial interface modules

Содержание PCD2.F2100

Страница 1: ...Document 27 649 Version ENG02 2018 08 15 Manual PCD2 F2xxx serial interface modules...

Страница 2: ...485 on module PCD2 F2100 port x 0 1 8 1 4 2 RS 232 on module PCD2 F2210 Port x 0 for modem 1 10 1 4 3 Belimo MP Bus on module PCD2 F2810 port x 0 1 11 1 5 PCD7 F1xxS serial interface modules for port...

Страница 3: ...d Comments ENG01 2018 02 08 2018 02 08 Translated from the german version ENG02 2018 08 15 Revised overview improved Chapter 2 0 2 Brand names and trademarks Saia PCD and Saia PG5 are registered trade...

Страница 4: ...Port x 0 RS 422 RS 485 Port x 1 slot for PCD7 F1xxS module PCD2 F2210 Port x 0 RS 232 Port x 1 slot for PCD7 F1xxS module PCD2 F2810 Port x 0 Belimo MP Bus Port x 1 slot for PCD7 F1xxS module 1 1 1 Se...

Страница 5: ...ock diagram PCD2 F2xxx UART 1 UART 2 PCD CPU I O Bus SPI Bus Interrupt Input I O Bus Interface CPLD Power supply 3 3 V I O Port Microcontroller ARM7 UART 1 SPI Slave Interface Interrupt Output UART 2...

Страница 6: ...defining the maximum communication capacity per PCD2 system The communication volume is determined by the peripheral devices connect ed This may be the case if for example a PCD2 is used as an S Bus s...

Страница 7: ...of the PCD7 F1xxS modules if required Port x 1 still without PCD7 F1xxS module Port x 0 fix depending on the PCD2 F2xxx module selected Serial communications modules with two serial interface ports PC...

Страница 8: ...405 5048 0 are also supplied Each serial port has its own individual 10 pin spring loaded terminal block Two type K spring loaded terminal blocks are fitted on the PCD2 F2xxx module the right for por...

Страница 9: ...ty mode SM2 S Bus master data mode SS1 S Bus slave parity mode SS2 S Bus slave data mode GS1 S Bus gateway slave parity mode GS2 S Bus gateway slave data mode GM S Bus gateway master Gateway always vi...

Страница 10: ...ystems enable users to create up to 8 additional serial interfaces Note every additional interface uses CPU capacity The use of these 8 ports depends on the type of communication the baud rate require...

Страница 11: ...electrically connected The line terminator is integrated into the module and can be connected to the module via a switch Switch for network terminator port x 0 RS 485 O C RS 422 connection Port x 0 RS...

Страница 12: ...PGND x1 RX TX x2 RX TX PGND RX TX RX TX GND RS 485 RS 485 RS 485 Peripherie device Terminal Line terminator 5 V RX TX n n 29 n n n n 28 RX TX 5 V Pull up 330 Ohm Termination Resistor 150 Ohm Segment...

Страница 13: ...ar for all modem connections including the RTS CTS DTR DSR and DCD RS 232 connection Port x 0 RS 232 10 pin spring loaded terminal block 0 PGND TxD 1 2 RxD RTS 3 4 CTS PGND 5 6 DTR DSR 7 8 COM DCD 9 R...

Страница 14: ...nnected to port x 0 Belimo connection Port x 0 Belimo MP Bus 10 pin spring loaded terminal block 0 PGND Acom 1 2 MST IN 3 4 PGND 5 6 7 8 9 MP Bus cabling 0 PGND Earth connection MP line 1 MP Multi poi...

Страница 15: ...odules will be used among others for the insertion of port x 1 of the PCD2 F2xxx modules A second interface can be mounted on each CD2 F2xxx module depending on the purpose of the application PCD7 F11...

Страница 16: ...actory setting Slider 2 1 C O Closed terminated RS 422 connection Port x 1 RS 422 10 pin spring loaded terminal block 0 PGND Tx 1 2 Tx Rx 3 4 Rx PGND 5 6 RTS RTS 7 8 CTS CTS 9 The line terminator in R...

Страница 17: ...3 RS 232 up to 115 kbit s suitable for modem connection PCD7 F121S serial interface module PCD7 F121S RS 232 connection Port x 1 RS 485 10 pin spring loaded terminal block 0 PGND TxD 1 2 RxD RTS 3 4...

Страница 18: ...ON C O Closed terminated Slider 1 2 ON C O Open not terminated factory setting RS485 connection Port x 1 RS 485 10 pin spring loaded terminal block 0 PGND Rx Tx 1 2 Rx Tx 3 4 PGND 5 6 7 8 SGD 9 x0 PGN...

Страница 19: ...Up to a maximum of 8 actuating drives and sensors can be connected PCD7 F180S Belimo connection Port x 1 Belimo MP Bus 10 pin spring loaded terminal block 0 PGND MP 1 2 MFT IN 3 4 PGND 5 6 7 8 SGD 9 M...

Страница 20: ...p 20 mA For completeness they are still listed here Their functions are the same as with the newer models with the S in the article number at the end PCD7 F110 Serial interface module RS 422 RS 485 PC...

Страница 21: ...lers can be used with which PCD2 F2xxx modules 2 1 PCD1 M22xx C15 A maximum of two PCD2 F2xxx modules can be used on the two slots The slots can be accessed with the following port addresses via commu...

Страница 22: ...xxx interface modules The slots can be accessed with the following port addresses via communication FBoxes or AWL commands PCD1 M2120 PCD1 M2160 PCD1 M2110 Room Module slot Module port address Module...

Страница 23: ...ie E A Slots folgender massen bezeichnet PCD2 M4560 PCD4 M4160 Module slot Module port address Module terminal block Module slot Module port address Module terminal block 0 100 101 Port x 0 Port x 1 0...

Страница 24: ...e diagram the I O slots are labelled as follows Module slot Module port address Module terminal block 0 100 101 Port x 0 Port x 1 1 110 111 Port x 0 Port x 1 2 120 121 Port x 0 Port x 1 3 130 131 Port...

Страница 25: ...ment 27 649 ENG02 2018 08 15 A Appendix A 1 Icons This symbol indicates that additional information on this topic exists in this manual a different manual or technical documentation There are no direc...

Страница 26: ...land Head office telephone 41 26580 30 00 SBC Support telephone 4126580 31 00 Fax 4126580 34 99 Email support support saia pcd com Support website www sbc support com SBC website www saia pcd com Inte...