3. VAV12 Operating Instructions Using the User Interface 

Please note these instructions are for Desktop or Touchpad viewing, the smart phone will have a similar layout. 

 

1. Open the User interface using the steps mentioned in 2.1, 2.2 or 2.3 

 

2. The Launch page will open. 

(Figure 11)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.1 Changing the System Mode 

 
Press the Auto, Heat, Cool or Vent Buttons. 

(Figure 11) 

Auto 

 Will switch between Heating and Cooling between zones. 

Cool 

 Cooling only setting 

Heat 

 Heating only setting 

Vent 

 Will only circulate ambient air 

 

3.2 Notes on Dynamic Energy Recovery 

 
Your SAI HVAC multi zone temperature control system modulates its output capacity to match the heat load. It 
continues to cool or heat individual zones until they reach the target temperature (set point). When all zones 
are at target temperature, the refrigeration cycle is switched off. On a system where dynamic energy recovery 
is disabled, any room can re-activate cooling or heating when the temperature moves away from set point by 
0.5°C. Dynamic energy recovery is a technology designed for structures that include a large central area 
surrounded by perimeter rooms.  The perimeter rooms lose and gain heat at a much faster rate than the 
central area. The reason for this phenomenon is that the portion of external walls and roof to room volume is 
significantly higher and the additional thermal mass of the central area reduces the rate at which heat is 
gained or lost. The dynamic energy recovery algorithm intervenes when a  perimeter zone calls for heating or 
cooling, it then measures the return air temperature  (positioned din the large central zone) to apply a 
proprietary algorithm that calculates the  flow needed to slow down the rate at which heat is gained or lost. 
The slider allows the user to find the right balance for their home or building between energy reduction and 
comfort.  The slider moves the point at which the worst performing zone can terminate dynamic energy 
recovery and force heating or cooling.   
The VAV12 zoning control is a unique part of the SAI HVAC system that provides the ability to dramatically 
reduce your energy bills. It is important to note that the average household uses 38% of their power bill on 
heating and cooling. It is also important to note that every degree Celsius difference between the inside 
temperature and the outside temperature adds 10% to the energy cost for that room. SAI HVAC

’s multi zone 

temperature control system automatically adjusts the airflow to individual rooms to make sure that cooling 
and heating overshot is eliminated.  There are 3 additional energy settings that are use adjustable that 

Figure 11

 

 Launch Page  

brochure. 

Mode Select 

 Auto, Cool, Heat and Vent 

Show All systems on network 

 Browse to other systems on your LAN network 

Содержание Compact Comfort VAV12

Страница 1: ...1 Copyright SAI HVAC 2021 2022 TM_VRAF_VAV12 21 003 Compact Comfort by SAI HVAC VAV12 Controls Install Manual Series 2 ...

Страница 2: ...VAC reserves the right to make changes and improvements to any of the products described in this document without prior notice Under no circumstances shall SAI HVAC be responsible for any loss of income or any special incidental consequential or indirect damages howsoever caused Warranty The contents of this document are provided as is Except as required by applicable law no warranties of any kind...

Страница 3: ...untdown Timer 9 3 4 Optional Cooling and Economy Settings 9 3 5 Setting the Global time schedule whole system 10 3 6 Setting Individual zones time schedules 10 3 7 Browse to Other Systems 11 3 8 Adjusting the Settings on a Zone 11 4 System Diagnostics 12 5 SAI HVAC VAV12 Controls 14 5 1 SAI HVAC VAV12 Navigator 14 5 1 1 Turning the System ON and OFF 14 5 1 2 Turning a Zone ON and OFF 14 5 1 3 Brow...

Страница 4: ...oaded without the need for you to do anything 1 4 Html User Interface The html user interface can be used on most devices with a browser from a Smartphone or tablet to PC The display results vary slightly depending on your device and browser type used Many people choose the iPad mini as their UI platform but a laptop PC or even your iPhone Samsung can be used to control your SAI HVAC product 1 5 R...

Страница 5: ...s own network via Wi Fi This means you can connect the clients smart device computer to the system Please note the Wi fi Dongle supplied must be used 1 Open your Wi Fi settings on your device and select the SAI VAV network Figure 1 if multiple chatterboxes ion site check for the Mac Address on the device you are connecting to 2 The Password is chatterbox Figure 2 3 Once connected to the controls n...

Страница 6: ...nd allow you access to your system NOTE Some older routers ship with UPNP disabled You should check the router instruction manual for details on how to check this setting Without UPNP enabled the system cannot connect Remember that after power failure the router may assign a different IP number to your system In this case you will need to scan the network with FING or similar program to find the n...

Страница 7: ...in page titled Your Local Devices with the Mac Address and system description You can click this link to go straight to the User Interface without having to log in Figure 9 4 Once you have received notice of your User Name and Password the client can go to the log in page enter the details then press Login to access their system outside of their LAN 5 The next screen that launches will have a list...

Страница 8: ...on of external walls and roof to room volume is significantly higher and the additional thermal mass of the central area reduces the rate at which heat is gained or lost The dynamic energy recovery algorithm intervenes when a perimeter zone calls for heating or cooling it then measures the return air temperature positioned din the large central zone to apply a proprietary algorithm that calculates...

Страница 9: ... system then requires a re start This feature is designed as a safe guard for properties where the air conditioning can be left on while not required Figure 12 Anytime there is an on event on the system in any zone the system will continue to operate This feature is most often used in combination with occupancy sensors When applied in this fashion you can move through your home the system automati...

Страница 10: ... wish to set the time schedule for Figure 14 2 Press the Schedules button Figure 14 3 Zone time schedules page launches 4 Select from 2 schedules Schedule A and Schedule B Figure 14 5 After selecting your schedule select which days and times you wish to turn on and off your zone Purple arrow Figure 14 6 Press the Home button when you have completed your selections Figure 15 or select another zone ...

Страница 11: ...led You can select which system you wish to control from here Figure 11 3 8 Adjusting the Settings on a Zone To change the temperature setpoint in a zone 1 Select the zone you wish to adjust 2 Adjust either up or down to select the desired temperature Temperature setpoint slider Temperature setpoint and room temperature display Figure 15 Zone temperature adjust brochure ...

Страница 12: ...ppear in the bottom right corner figure 19 The diagnostic button will appear in the same place regardless of which zone you select or if you select System Overview This will launch the diagnostics screen figure 20 Please note The information shown in the diagnostic page will be specific to the System Overview or the particular zone selected There is no system summary page that shows diagnostic inf...

Страница 13: ...13 Copyright SAI HVAC 2021 2022 TM_VRAF_VAV12 21 003 Figure 20 Diagnostics Screen brochure ...

Страница 14: ...m ON and OFF Press the ON OFF Button when on the main screen to turn all zones ON or OFF 5 1 2 Turning a Zone ON and OFF Press the ON OFF Button when in the zone screen to turn an individual zone ON or OFF Set Button Navigate Left Navigate Right Current Mode Current Temperature Navigate Up On Off Navigate Down Temperature Set Point ...

Страница 15: ... Using the Single Button Capacitive Touch Room Controller The Single button room controller is an easy to use on off controller for your room or zone It has a built in temperature sensor with a central button for turning a zone on or off If the zone is switched off the LED indicator around the capacitive touch button will be turned off Otherwise the LED indicator has three different colours that s...

Страница 16: ...16 Copyright SAI HVAC 2021 2022 TM_VRAF_VAV12 21 003 5 3 Surface 7 Touchpad Capacitive Touch Buttons Page Navigation ...

Страница 17: ...17 Copyright SAI HVAC 2021 2022 TM_VRAF_VAV12 21 003 5 4 Surface 5 Touchpad The Surface 5 functionality can be directly related back to the GUI information ...

Страница 18: ...nstaller for a replacement filter a charge will apply 6 2 Outdoor Unit Do not place any object in front of the condenser Keep free of grass leaves and any other form of debris This will allow for proper air flow and ensure unit efficiency 6 3 Vents Return Air Grill Regular cleaning of the return air grill and air vents is recommended This will prevent build up of dust and dirt 6 4 Controllers Clea...

Страница 19: ...tioner does not operate Has the mode been set correctly Is at least one zone ON Has the setpoint for ON zones been set low enough for cooling or high enough for heating Has the circuit breaker been tripped The air conditioner does not cool heat effectively Has the mode been set correctly Are all the windows and doors closed Are the filters dirty Are the intake or outlet vents of the outdoor unit o...

Отзывы: