background image

Waterproof Scale Operation Instruction

7

if scale is under this weight, “ LO ” indication is shinning with alert buzzer.
Press

[►] & [▲]

key to set the point weight, then press

[ MODE ]

to confirm and finish.

For example:

For one 30kg scale, desired weight is 10kg, deviation value is ±0.2kg.

Step 1: Pressing

[►] & [▲]

key to set the point weight “10.20kg”, the screen will display 10.20 kg

and “

HI

” indication is shinning, , then press

[ MODE ]

to confirm and next to Step 2..

Step 2: Pressing

[►] & [▲]

key to set the lowest weight 9.80kg, the screen will display 9.80 kg

,

“ LO ” indication is shinning,then press

[ MODE ]

to confirm and next step.

Step 3: After back to normal weighing, load the goods in scale, if over or under this two points weight,

the

“HI”

or

“LO”

indication will be shinning with alert buzz to annunciate to user. But the

weight is in the range of setting, the “OK” indication will shows without alert buzz.

6.5. SET OF EFFECTIVE TERM IN CHECK WEIGHING MODE

Set “ SPt X”. It is parameter of the effective term of check weighing mode. It only works when

the check weighing function is working.

X=0, means the indicator will keep checking and alert, even if the reading is unstable.
X=1, means the indicator will alert after the reading is stable.
X=2~9, means the indicator will alert when the reading appear same times that preset the number .It

happens in reading is unstable.

Press

[▲]

key to select and press

[ MODE ]

to confirm and next step.

6.6. SETTING OF AUTO SHUTDOWN PROTECTION FOR LOW BATTERY

Set “ PLo X”.It is parameter of Auto shutdown protection function.

It displays

PLO XX

.

“XX”

means the lowest percentage of battery capacity. When the capacity

of battery is lower than the setting value, the indicator will be shutdown and need to be charged. It is very
helpfully to increase the life of battery.

Press

[▲]

key to select from

“0~40”

and press

[MODE]

to confirm and exit to weighing mode.

XII. SETTING OF WEIGH UNIT

Press and hold

[MODE]

key for 3 seconds, the screen will display Unit = X . It is the menu of unit

weigh setting. X is from 0-4 for 5 kinds of unit weigh.

0 =g, 1= kg, 2 = lb, 3= lb.oz, 4= PCS

Press

[▲]

key to select and press

[MODE]

to confirm and exit to weighing mode.

XIII. COUNTING FUNCTION OPERATION

Attention:

In counting mode, the scale isn’t allowed for weight unit switching function. The function

must be set in

Step

Содержание KW1000G-3

Страница 1: ...Waterproof Scale Operation Instruction 1 WATERPROOF SCALE Operation Instruction Ver1 0...

Страница 2: ...PREPARING TO USE THE SCALE 1 III INTRODUCTION 1 IV LCD DISPLAY SYMBOLS 2 V KEYBOARD FUNCTION 3 VI GENERAL PARAMETER 4 VII CONNECTION OF INTERFACE 6 VIII MEANS OF POWER SUPPLY CHARGING 7 IX COUNTING F...

Страница 3: ...our leveling feet to set the level of scale platform 3 Avoid operating the scale in direct sunlight or drafts of any kind 4 Take away any weight that might be on the platform before the scale is switc...

Страница 4: ...pacity indication is displayed shortly on the display the internal battery needs to be recharged The scale will power off automatically without recharging after the low battery symbol shows upon for 2...

Страница 5: ...Capacity Shining is charging Kg lb lb oz g PCS Weighing unit HI OK LO Checking weighing Front panel Keyboard V KEYBOARD FUNCTION KEYS DESCRIPTIONS Turn on off The indicator will be turned on when pre...

Страница 6: ...ANDBY MODE Set Pr AB It is parameter of LED display is closed for saving power A for Standby mode B for the effective time A 0 means LED is lighted all the time A 1 means Only STB indication is lighte...

Страница 7: ...n is working X 0 means the indicator will keep checking and alert even if the reading is unstable X 1 means the indicator will alert after the reading is stable X 2 9 means the indicator will alert wh...

Страница 8: ...MODE enter counting mode and it displays n XXXXX Step 3 Press key to input the sample number and it displays n 00100 Step 4 Press MODE to confirm and upload the sample unit Step 5 Loading the weight s...

Страница 9: ...ODE to confirm and enter into the next step Step 3 Display Resolution The screen displays XXXXX The value shown is the display resolution Display resolution division kg full capacity kg Example take 0...

Страница 10: ...able 4 X 3 Indicator will send out 1 data after the weighing is stable Press to select the value and press MODE to confirm and finish to set the Serial protocol Step 6 Weight response speed Filtering...

Страница 11: ...RROR SIGNAL There will shows error signal when the scale have some problem Error 1 means calibration isn t workable weight is too light or division is too high Error 2 means wrong zero check the load...