background image

Waterproof Scale Operation Instruction

6

VI. GENERAL PARAMETER SETTING

* Plug the circuit breaker JP1 into ‘off’, and the following operation can be performed.

Press and hold

[MODE]

&

[→0←]

key for 3 seconds, the screen will display

====== . Press

[MODE]

to enter the menu. It is the menu of general function setting.

6.1 SETTING OF AUTOMATIC POWER OFF

Set “OFF = 0”, it is parameter of automatic power off function.

There are 7 choices for preset shut down time:

0~60min.

Choices 1~60minutes denotes respectively

that indicator will power off automatically if there is no changes on weighing value and no operation on

keyboard. Choice 0 denote that automatic power function is not available.

Press

[►] & [▲]

to select then press

[MODE]

to confirm.

6.2 SETTING OF BUZZER

Set “bP on”, it is parameter of Buzzer function.

Press

[▲]

to select “On” or “OFF” to turn on/off the buzzer. Non-buzzing mode will help decreasing

power consumption. Press

[MODE]

to confirm.

6.3. SETTING OF STANDBY MODE

Set “ Pr. AB”. It is parameter of LED display is closed for saving power.
A

for Standby mode.

B

for the

effective time.

A=0, means LED is lighted all the time.
A=1, means Only STB indication is lighted.
A=2, means Only Zero indication is lighted.
A=3, means the Date & time display.
A=4, means the Company name, the date & time display.

B=1~9, means the effective time 1~9min. After the time, the back light mode will operate.

Press

[►] & [▲]

to select then press

[MODE]

to confirm.

6.4 SETTING OF CHECK WEIGHING FUNCTION

Set “ -HOL-”. It is parameter of Check weighing function.

The indicator has a check weighing function which allows scale to check weigh, making the set point

weight quick and accurate. Ignore the function to press

[ MODE ]

to next step.

Press

[►]

to enter setup menu. Below is the operation:

Step 1:

The screen displays XXXX kg and

“HI”

indication is shining, please to set the highest weight.

If scale is over this weight, “

HI

” indication is shinning with alert buzzer.

Press

[►] & [▲]

key to set the point weight, then press

[ MODE ]

to confirm and next to step 2.

Step 2:

The screen displays XXXX kg and

“LO”

indication is shining, please to set the lowest weight,

Содержание KW1000G-3

Страница 1: ...Waterproof Scale Operation Instruction 1 WATERPROOF SCALE Operation Instruction Ver1 0...

Страница 2: ...PREPARING TO USE THE SCALE 1 III INTRODUCTION 1 IV LCD DISPLAY SYMBOLS 2 V KEYBOARD FUNCTION 3 VI GENERAL PARAMETER 4 VII CONNECTION OF INTERFACE 6 VIII MEANS OF POWER SUPPLY CHARGING 7 IX COUNTING F...

Страница 3: ...our leveling feet to set the level of scale platform 3 Avoid operating the scale in direct sunlight or drafts of any kind 4 Take away any weight that might be on the platform before the scale is switc...

Страница 4: ...pacity indication is displayed shortly on the display the internal battery needs to be recharged The scale will power off automatically without recharging after the low battery symbol shows upon for 2...

Страница 5: ...Capacity Shining is charging Kg lb lb oz g PCS Weighing unit HI OK LO Checking weighing Front panel Keyboard V KEYBOARD FUNCTION KEYS DESCRIPTIONS Turn on off The indicator will be turned on when pre...

Страница 6: ...ANDBY MODE Set Pr AB It is parameter of LED display is closed for saving power A for Standby mode B for the effective time A 0 means LED is lighted all the time A 1 means Only STB indication is lighte...

Страница 7: ...n is working X 0 means the indicator will keep checking and alert even if the reading is unstable X 1 means the indicator will alert after the reading is stable X 2 9 means the indicator will alert wh...

Страница 8: ...MODE enter counting mode and it displays n XXXXX Step 3 Press key to input the sample number and it displays n 00100 Step 4 Press MODE to confirm and upload the sample unit Step 5 Loading the weight s...

Страница 9: ...ODE to confirm and enter into the next step Step 3 Display Resolution The screen displays XXXXX The value shown is the display resolution Display resolution division kg full capacity kg Example take 0...

Страница 10: ...able 4 X 3 Indicator will send out 1 data after the weighing is stable Press to select the value and press MODE to confirm and finish to set the Serial protocol Step 6 Weight response speed Filtering...

Страница 11: ...RROR SIGNAL There will shows error signal when the scale have some problem Error 1 means calibration isn t workable weight is too light or division is too high Error 2 means wrong zero check the load...

Отзывы: