4.1.2

 PLEASE CALIBRATE SCALE REGULARLY.

   

4.1.3

 DO NOT OVERLOADING. DO NOT THROW HEAVY THINGS ON THE SCALE VIOLENTLY. THE 

DAMAGE  FOR  OVERLOADING  IS  NOT  WITHIN  THE  RANGE  OF  GUARANTEED 
MAINTENANCE.

 

4.1.4

 DON’T TOUCH CHEMICALS SUCH LIKE SOLVENT, ETC.

 

4.1.5

 KEEP THE SCALE CLEAN IN ORDER TO WEIGHING WELL.

 

4.1.6

 THERE IS A LEAD SEAL ON THE BOTTOM OF THE SCALE. USERS ARE NOT ALLOWED TO 

REMOVE  THE  SEAL.  IF  THE  SEAL  IS  DAMAGED  THE  SCALE  IS  NOT  GUARANTEED  FOR 
MAINTENANCE.

 

4

.2

FOR SEALED LEAD ACID BATTERY   

4.2.1THE  WORKING  TEMPERATURE  OF  BATTERY  IS  -10

~+40

.  IT  CAN  BE  CIRCLE  CHARGED 

ABOUT 300 TIMES AT 20

.   

4.2.2 PLEASE CORRECTLY CONNECT LINE BETWEEN ADAPTER AND BATTERY, BLACK TO BLACK, 

RED TO RED.   

4.2.3PLEASE  CHARGE  IN  TIME.  IF  YOU  DON

T  USE  IT  IN  A  LONG  TIME,  PLEASE 

CHARGE AT LEAST EVERY 3 MONTHS. 

4.2.4

IF THE USING TIME OF BATTEY BECOMES SHORT, PLEASE CHANGE NEW ONE. 

4.2.5 IT HAS A ONE MONTH GUAANTEE. 

 

 

ADJUSTMENT

 

1.

PUSH  THE  ADJUST  KEY  TO  SWITCH  ON,  THE  SWITCH  IS  ON  THE  BOTTOM  OF 

THE SCALE, LOCKED WITH A SEAL .PRESS 

ON/ZERO

  KEY, AFTER A WHILE 

START TO ADJUST

; 

IF SHOW 

ERR01,ADJUST SWITCH IS OFF 

 

2.

PRESS 

SET/0~9

  AND 

ON/ZERO

  KEY THE SAME TIME, CHOOSE WEIGHING 

UNITS-KG,  LB  OR  COUNTING  FUNCTION,  PRESS 

TARE

  TO  CONFIRM.  IF 

DON’T CHOOSE LB, PRESS 

SET/0~9

, IT DISPLAYS PCSH9, PRESS 

TARE

 

TO  CONFIRM.  THEN  THE 

DISPLAY  SHOWS  “C”.  “C”  IS  THE  MAX.  CAPACITY, 

PRESS 

SET/0~9

TO  CHOOSE  C-300,C-600,C-1500,C-3000,C-6000,C-15000, 

AND PRESS 

TARE

  TO CONFIRM

;   

3. 

NOW  IT  DISPLAYS  1P(ONE  POINT  CALIBRATION)  OR  3P(THREE  POINTS 

CALIBRATION)

PRESS SET/(0~9)

TO CHOOSE 1P OR 3P

PRESS 

TARE

Содержание A1-300

Страница 1: ...WATERPROOF ELECTRONIC SCALE USER S MANUAL...

Страница 2: ...HE CHARACTERISTICS OF SATISFACTORY IN PERFORMANCE ACCURATE IN WEIGHING CONVENIENT FOR CARRYING CHEAP IN PRICE IT IS STURDY AND DURABLE AND WIDELY USED IN NOT ONLY RETAIL STORES AND WEIGHING OF RATION...

Страница 3: ...10 40 1 3STORAGE TEMPERATURE 25 50 1 4POWER 6V2 3AH SEALED LEAD ACID RECHARGEABLE BATTERY CHARGE THE BATTERY WITH THE BUILT IN CHARGER 1 5N W 2 9KG PC 1 6PACKING 4PCS CTN 14KG 58 33 32CM3 2KEYBOARD A...

Страница 4: ...SE TURN ON AND REDUCE TARE WEIGHT Err01 ADJUST SWITCH IS OFF WHEN CALIBRATING Err02 COUNTING SAMPLE WEIGHT IS TOO SMALL Err03 ONE POINT CALIBRATE WEIGHT IS TOO SMALL Err08 CHIP ERROR C _END RECHARGE I...

Страница 5: ...ZERO LAMP LIGHTING PRESS THE TARE KEY THE TARE LAMP OFF 3 6SAVE POWER FUNCTION ZERO AFTER 40 SECONDS AUTO SAVE POWER SHOWS 0 PUT A WEIGHT START WEIGHING 3 7BATTERY LAMP HIGH MEANS VOLTAGE HIGHER THAN...

Страница 6: ...2 UNITS CHANGE UNIT 3 9 2 1WHEN IT DISPLAYS UNITS PRESS TARE TO ENTER PRESS SET 0 9 TO CHANGE PRESS TARE TO CONFIRM UNITS H9 KG 9 G PCS COUNTING LB LB DECIMAL POUNDS LB OZ BRITISH POUNDS OUNCES 3 9 2...

Страница 7: ...PRESS TARE TO ENTER PRESS SET 0 9 TO CHOOSE DIVISION PRESS TARE TO CONFIRM THERE HAVE 4 DIVISIONS OF EACH CAPACITY WHEN YOU CHOOSE THE LITTLE ONE THE SPEED OF DISPLAY WILL BE SLOWER 3 9 8 LU BRIGHTNE...

Страница 8: ...BLACK RED TO RED 4 2 3PLEASE CHARGE IN TIME IF YOU DON T USE IT IN A LONG TIME PLEASE CHARGE AT LEAST EVERY 3 MONTHS 4 2 4IF THE USING TIME OF BATTEY BECOMES SHORT PLEASE CHANGE NEW ONE 4 2 5 IT HAS...

Страница 9: ...9 3 SECONDS TO ADD UP AND THEN PRESS SET 0 9 TO STOP 60000 INTERNAL NUMBER MEANS THE MAX CAPACITY PRESS TARE IT SHOWS CAEND EXIT ADJUSTMENT DON T NEED CHANGE GRAVITY FOR LOCAL USAGE PRESS TARE B 1P ON...