background image

 

3.2.2TURN OFF 

PRESS [OFF] KEY.   

3.2.3AUTO-OFF 

      WHEN POWER AUTO OFF IS SET,AFTER 10 MINUTES IN ZEROING, AUTO-OFF.

  SEE 3.9.3   

 

3.2.4LOW VOLTAGE AUTO-OFF 

WHEN THE VOLTAGE LOWER THAN 5.6V, THEN POWER-OFF. 

3.3

ZERO 

WHEN WITHOUT TARING THE WEIGHT DISPLAY I

S ≤3% MAX. CAPA., PRESS THE 

[ON/ZERO] KEY, THE D

ISPLAY SHOWS “ 0 ”, THE ZERO LAMP LIGHTING. 

3.4WEIGHING 

PUT WEIGHT TO PAN. 

3.5TARE WEIGHING 

PLACE ONE CONTAINER ON PLATE, PRESS THE [TARE] KEY, THE WEIGHT DISPLAY 

IS “ 0 ”, 

THE  “ZERO”  LAMP  OFF,  THE  “TARE”  LAMP  LIGHTING.  PICK  UP  THE  CONTAINER,  THE 

WEIGHT DISPLAY IS NE

GATIVE, THE “ZERO” LAMP LIGHTING, PRESS THE [TARE] KEY, THE 

“TARE” LAMP OFF. 

 

  3.6SAVE POWER FUNCTION 

ZERO AFTER 40 SECONDS, AUTO SAVE POWER, 

SHOWS “ 0 ”. PUT A WEIGHT START 

WEIGHING 

3.7BATTERY LAMP 

 

“HIGH”  MEANS  VOLTAGE  HIGHER  THAN  6.3V,  “MID”  MEANS  VOLTAGE  BETWEEN  6V 

AND 6.3V, “LOW” MEANS VOLTAGE LOWER THAN 6V. 

 

3.8CHARGE 

POWER  SUPPLIED  BY  A  INTERNAL  RECHARGEABLE  LEAD  ACID  BATTERY  (6V/2.3AH). 
WHEN IT SHOWS “-BATLO-”. PLEASE TURN OFF AND CHARGE IMMEDIATELY. THE TIME OF 

FULL CHARGING IS 12 HOURS.

NEED NOT TURN ON WHEN CHARGING

 

 

      3.9

SET AND USE PARAMETER 

PRESS <SET/0~9>3 SECONDS

ENTER  SET  AND  SHOW  MAIN  MENU

PRESS <SET/0~9> CONTINUOUS

IT DISPLAYS

 

RANGE(SET LIMIT) 

UNITS(CHOOSE UNIT) 

A-OFF

CHOOSE AUTO POWER OFF

 

                FILT(SET DISPLAY MODE) 

ZERO(SET AUTO ZERO) 

BUZZLE(SET BUZZLE) 

D(CHOOSE DIVISION) 

Содержание A1-300

Страница 1: ...WATERPROOF ELECTRONIC SCALE USER S MANUAL...

Страница 2: ...HE CHARACTERISTICS OF SATISFACTORY IN PERFORMANCE ACCURATE IN WEIGHING CONVENIENT FOR CARRYING CHEAP IN PRICE IT IS STURDY AND DURABLE AND WIDELY USED IN NOT ONLY RETAIL STORES AND WEIGHING OF RATION...

Страница 3: ...10 40 1 3STORAGE TEMPERATURE 25 50 1 4POWER 6V2 3AH SEALED LEAD ACID RECHARGEABLE BATTERY CHARGE THE BATTERY WITH THE BUILT IN CHARGER 1 5N W 2 9KG PC 1 6PACKING 4PCS CTN 14KG 58 33 32CM3 2KEYBOARD A...

Страница 4: ...SE TURN ON AND REDUCE TARE WEIGHT Err01 ADJUST SWITCH IS OFF WHEN CALIBRATING Err02 COUNTING SAMPLE WEIGHT IS TOO SMALL Err03 ONE POINT CALIBRATE WEIGHT IS TOO SMALL Err08 CHIP ERROR C _END RECHARGE I...

Страница 5: ...ZERO LAMP LIGHTING PRESS THE TARE KEY THE TARE LAMP OFF 3 6SAVE POWER FUNCTION ZERO AFTER 40 SECONDS AUTO SAVE POWER SHOWS 0 PUT A WEIGHT START WEIGHING 3 7BATTERY LAMP HIGH MEANS VOLTAGE HIGHER THAN...

Страница 6: ...2 UNITS CHANGE UNIT 3 9 2 1WHEN IT DISPLAYS UNITS PRESS TARE TO ENTER PRESS SET 0 9 TO CHANGE PRESS TARE TO CONFIRM UNITS H9 KG 9 G PCS COUNTING LB LB DECIMAL POUNDS LB OZ BRITISH POUNDS OUNCES 3 9 2...

Страница 7: ...PRESS TARE TO ENTER PRESS SET 0 9 TO CHOOSE DIVISION PRESS TARE TO CONFIRM THERE HAVE 4 DIVISIONS OF EACH CAPACITY WHEN YOU CHOOSE THE LITTLE ONE THE SPEED OF DISPLAY WILL BE SLOWER 3 9 8 LU BRIGHTNE...

Страница 8: ...BLACK RED TO RED 4 2 3PLEASE CHARGE IN TIME IF YOU DON T USE IT IN A LONG TIME PLEASE CHARGE AT LEAST EVERY 3 MONTHS 4 2 4IF THE USING TIME OF BATTEY BECOMES SHORT PLEASE CHANGE NEW ONE 4 2 5 IT HAS...

Страница 9: ...9 3 SECONDS TO ADD UP AND THEN PRESS SET 0 9 TO STOP 60000 INTERNAL NUMBER MEANS THE MAX CAPACITY PRESS TARE IT SHOWS CAEND EXIT ADJUSTMENT DON T NEED CHANGE GRAVITY FOR LOCAL USAGE PRESS TARE B 1P ON...

Отзывы: