manualshive.com logo in svg
background image

1. SAFETY ADVICE

2. START UP

Make sure there is no pressured air remained in 

the tank before using. If there is, release it with 

turning  release  cock  counterclockwise  until 

pressure bleeds down.

1. Loosen thumb nut and swing bolt, then remove 

lid assembly.

2. Pour material into the tank.

3. Replace the lid assembly and tighten securely.

4. Connect the air supply hose to the air inlet, 

which is fitted above pressure regulator. It is better 

for  the  air  supply  hose  to  pass  through  a 

transformer to filter dirt from air and remove 

entrained water and oil.

5. Connect the atomization air hose to the air 

outlet.

6. Connect material hose to the fluid outlet.

7. Turn on the air supply, turn pressure regulator 

clockwise to gain working pressure. Make sure 

not to adjust it over 4 bar (60 psi).

8. Atomization  air  for  the  spray  gun  can  be 

adjusted at the gun by means of an air adjusting 

valve or adding and air regulator kit to the tank.

9. Operate spray gun according to the instructions 

attached with it.

3. MAINTENANCE CLEANING EQUIPMENT

1. Release all pressure air.

2. Loosen all the thumb nuts.

3. Loose air cap retaining ring on spray gun about 

three turns.

4. Cup cloth over air cap on the gun and pull 

trigger. This will force product back into the tank.

5. Empty the tank. Then, clean all the parts which 

are on contact with the product with a suitable 

solvent.

6. Pour clean solvent into the tank.

7. Replace the lid and tighten all the thumb nuts.

8. Spray until clean solvent appears.

9. Repeat steps 1 - 4 in order to force the solvent 

back to the tank.

-  5  -

5. SAFETY

1. For all repairs, disconnect the unit from the 

compressed air network.

2. Premises must be well ventilated and there 

must  not  be  any  direct  exposure  to  flames 

(cigarettes, lamps, etc.) when spraying a product.

3. Use approved breathing units.

4. Use goggles and ear protectors.

5.  Use  Sagola  antistatic  hoses  to  eliminate 

possible electrical discharges that might create 

the risk of fire or explosion.

6. The use of solvents and/or detergents that 

contain 

halogenated 

hydrocarbons 

(Trichlorethane, Methyl chloride, etc.) may cause 

chemical reactions in the unit as well as in its 

zinc-coated components (trichloroethane mixed 

with small amounts of water produces hydrochloric 

acid). For this reason, these components may 

rust and in extreme cases the chemical reaction 

caused may be explosive.

4. TROUBLE SHOOTING

PROBLEM 

CAUSE 

SOLUTION 

Indicator on air pressure gauge is out of function.

Fluid or air leak out from lid gasket.

Air  leak  out  from  release  cock  after  being 

screwed.

Broken or damaged

Defective lid gasket or thumb 

nuts are not tight enough.
O-ring in it maybe damaged.

Replace

Replace or    

tighten.
Replace

1. Before putting the unit into operation, it is 

advisable to read all the instructions indicated 

below carefully.

2. Likewise, accident prevention rules, regulations 

and guidelines for work centres and current laws 

and restrictions must be taken into account.

3. The unit must be used only by personnel who 

have been trained adequately in their handling, 

and  only  for  the  uses  for  which  it  has  been 

designed.

4. This pressure tank is only allowed to provide 

pressurized material up to maximum load of 4 bar 

(60 psi). Exceed this allowable load can result in 

explosion.

5. The safety valve is designed to protect the tank 

from over pressurization.

6. Do not midified the pressure pot.

7. Use antistatic air hoses. Should an antistatic 

air hose not be available, you must attach the unit 

to a groung connection in order to eliminate any 

static electricity.

Содержание 610

Страница 1: ...Calder n de presi n 610 610 pressure pot m a n u a l d e i n s t r u c c i o n e s l i s t a d e r e p u e s t o s i n s t r u c t i o n m a n u a l s p a r e p a r t s l i s t...

Страница 2: ...girando el regulador en la direcci n contraria a las agujas del reloj hasta que la presi n se reduzca 1 Afloje la tuerca y tornillo para a continuaci n quitar la cubierta del calder n 2 Coloque el mat...

Страница 3: ...mas comunitarios de los usuarios En Vitoria Gasteiz a 01 05 2009 Director General Este aparato ha sido fabricado con rigurosa precisi n Habiendo sido sometido a numerosos controles antes de su salida...

Страница 4: ...1 56410077 1 02 57550112 1 04 56418496 1 05 56418497 1 06 56417505 1 07 56456801 1 N Code U 08 54210279 1 09 54550025 2 10 56414922 1 11 49000731 1 12 49000732 1 08 05 4u 12 10 Este dibujo no es la li...

Страница 5: ...ilated and there must not be any direct exposure to flames cigarettes lamps etc when spraying a product 3 Use approved breathing units 4 Use goggles and ear protectors 5 Use Sagola antistatic hoses to...

Страница 6: ...jected to a large number of controls before it left the factory The GUARANTEE is for 2 years counted as of the date of purchase which will be indicated by the establishment where the apparatus is purc...

Страница 7: ...at Kaufdatum Data de Compra Data di aacquisto E mail Tel Fax Sello Stamp Cachet Stempel Selo Timbro GUARANTEE C0NDITIONS CONDITIONS DE GARANTIE CONDICIONES DE GARANT A CONDI ES DA GARANTIA CONDIZIONI...

Страница 8: ...NCIA T CNICA GARANT A DE REPARACI N PROFESIONAL TECHNICAL REPAIR SERVICE PROFFESIONAL REPAIR GUARANTEE SERVICE D ASSISTANCE TECHNIQUE GARANTIE DE R PARATION PROFESSIONNELLE TECHNISCHER DIENST PROFESSI...

Отзывы: