4. - INSTALLATION AND SWITCH ON

 

 

4.1 - PRODUCT INSTALLATION

 

 

- Do not shake the device. Avoid the use of too much force during installation or unit fixing.

 

- The unit can be installed on the floor resting on the rubber feet, on the wall, ceiling or on a 
truss.

 

 

 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 

WARNING! IT'S REQUIRED

 

the mounting of the safety rope (PLH232 - PLH248 

sold separately) in the case where the product is 

hung on a wall, ceiling or on a truss. Except when the 

device is placed in the floor, the safety cable is 

always required.

 

 

Содержание ARCHERB1

Страница 1: ...ARCHER B1 BEAM MOVING HEAD 1R Order code SG ARCHERB1 MANUALE UTENTE USER MANUAL...

Страница 2: ...INSTALLAZIONE ED ACCENSIONE p 7 5 ISTRUZIONI PER L USO p 9 6 MANUTENZIONE p 12 7 SPECIFICHE TECNICHE p 13 INDEX 1 INTRODUCTION p 14 2 SAFETY INSTRUCTIONS p 15 3 OPENING AND CONTROL p 17 4 INSTALLATIO...

Страница 3: ...te a separare questo prodotto da altri tipi di rifiuti e di riciclarlo in maniera responsabile per favorire il riutilizzo sostenibile delle risorse materiali Gli utenti domestici sono invitati a conta...

Страница 4: ...odotto Il cavo di sicurezza deve essere debitamente agganciato al dispositivo e fissato alla struttura di sostegno in modo che in caso di cedimento del sistema di supporto primario si abbia la minore...

Страница 5: ...e sovraccarichi Se il cavo di alimentazione esterno di questa apparecchiatura da illuminazione danneggiato deve essere sostituito con un cavo speciale disponibile esclusivamente presso i rivenditori P...

Страница 6: ...i non siano presenti o siano danneggiate contattare immediatamente il proprio fornitore e conservare l imballaggio per la verifica ATTENZIONE Se l apparecchio stato esposto a drastici sbalzi di temper...

Страница 7: ...it pu essere installata a pavimento in appoggio sugli appositi piedini in gomma a parete a soffitto o su truss ATTENZIONE E OBBLIGATORIO il montaggio della fune di sicurezza PLH232 PLH248 venduta sepa...

Страница 8: ...ttato come indicato nella targhetta dei dati elettrici 4 3 COLLEGAMENTO ALLA CATENA DMX Utilizzare un cavo conforme alle specifiche EIA RS 485 bipolare intrecciato schermato 120Ohm di impedenza caratt...

Страница 9: ...rimane all ultima posizione impostata OFF in caso di mancanza del segnale DMX la macchina torna a zero Display reverse ON OFF Inversione display Display delay off ON OFF ON spegnimento del display do...

Страница 10: ...ceso ma che non invia nessun segnale DMX oppure il trasmettitore spento UNLINK fisso Il proiettore non linkato a nessun trasmettitore 5 2 MODALITA DMX Modalit Canali Funzione Valore Descrizione 13 14...

Страница 11: ...bo 13 076 085 Gobo 1 shacking da lento a veloce 086 095 Gobo2 shacking da lento a veloce 096 105 Gobo 3 shacking da lento a veloce 106 115 Gobo 4 shacking da lento a veloce 116 125 Gobo 5 shacking da...

Страница 12: ...restazioni l apparecchio deve essere pulito frequentemente Scollegare l apparecchio della corrente e lasciarlo raffreddare per almeno 35 minuti onde evitare il rischio di bruciature Utilizzare un aspi...

Страница 13: ...a colori Ruota colori con 12 colori bianco Ruota gobo Ruota gobo con 13 gobo fissi bianco Angolo del fascio di luce 2 5 Prisma rotante a 8 facce Prisma lineare Filtro frost Shutter meccanico e effetto...

Страница 14: ...to the environment the user is encouraged to separate this product from other kinds of wastes and recycle it responsibly to promote the sustainable reuse of material resources Home users are encourage...

Страница 15: ...The safety cable must be properly attached to the device and fixed to the supporting structure so that in case of failure of the primary supporting system it has the lowest possible fall of the device...

Страница 16: ...Your PROEL dealer Never operate the equipment with lenses and or covers missing or damaged In case of non use it is recommended to unplug the projector from the mains MAINTENANCE Before starting any m...

Страница 17: ...RNING If the product has been exposed to drastic temperature changes let the unit turned off until it reaches room temperature because the presence of condensation can damage the product if it is turn...

Страница 18: ...ixing The unit can be installed on the floor resting on the rubber feet on the wall ceiling or on a truss WARNING IT S REQUIRED the mounting of the safety rope PLH232 PLH248 sold separately in the cas...

Страница 19: ...the electrical data label 4 3 CONNECTION TO THE DMX CHAIN Use a cable conforming to specifications EIA RS 485 pole twisted shielded 120Ohm characteristic impedance and low capacity SAGITTER SG DMX3 SG...

Страница 20: ...f no DMX the projector stay in the last position OFF if no DMX the projector goes to zero Display reverse ON OFF Display reverse Display delay off ON OFF ON display switches of after some minutes OFF...

Страница 21: ...but disconnected from DMX signal or the transmitter is switched OFF UNLINK fixed The projector is UNLINKED from any transmitter 5 2 DMX MODE Channels mode Function Values Description 13 14 16 1 1 1 PA...

Страница 22: ...o wheel 000 010 Open 011 015 Gobo 1 016 020 Gobo 2 021 025 Gobo 3 026 030 Gobo 4 031 035 Gobo 5 036 040 Gobo 6 041 045 Gobo 7 046 050 Gobo 8 051 055 Gobo 9 056 060 Gobo 10 061 065 Gobo 11 066 070 Gobo...

Страница 23: ...124 No function 125 149 Sound mode microphone sensitivity set by display 150 174 No function 175 199 Lamp OFF 200 224 No function 225 255 Lamp ON 6 MAINTENANCE To ensure optimal performance the unit m...