background image

FILTRAZIONE

FILTRATION

DIF.P

DIF.A

MANUALE DI MONTAGGIO 
INSTALLAZIONE E MANUTENZIONE

Le procedure contenute 
all’interno di questo ma-
nuale devono essere svol-
te da personale qualificato 
e si  raccomanda di utiliz-
zare i relativi DPI previsti 
dalla legislazione locale.

ASSEMBLY INSTALLATION INSTRUCTION 
AND MAINTENANCE MANUAL

The procedure listed into 
this manual should be 
carried out by qualified 
personnel and we recom-
mend to use relevant indi-
vidual protection devices 
as advised by the local 
legislation.

MANUEL DE MONTAGE D’INSTALLATION 
D’UTILISATION ET D’ENTRETIEN

Les procédures énoncées 
dans ce manuel doivent 
être réalisées par du 
personnel qualifié selon les 
dispositifs de protection 
individuelle prévus par la 
législation en vigueur.

Содержание DIF.P

Страница 1: ...EMBLY INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL The procedure listed into this manual should be carried out by qualified personnel and we recom mend to use relevant indi vidual protection device...

Страница 2: ...RALE OU SUP RIEURE Terminal filter hoods for contamination controlled environments 1 HANDLING To avoid any possible dam age to the filters during the installation of the housings we recommended to ke...

Страница 3: ...ne di entrambe le pellicole1 2 Terminal filter hoods for contamination controlled environments 2 REMOVE THE PROTECTIVE FILM CASO A Only remove the spigot film1 Removal of the film below 2 ONLY BEFORE...

Страница 4: ...rosoffitto false ceiling frame cadre faux plafond CASO A CASE A CAS A DIF P DIF A SIEF_20200507_DIF P DIF A _M 4 Terminali filtranti per ambienti a contaminazione controllata 3 MONTAGGIO Prima del mon...

Страница 5: ...UM TECHNICAL CLEARANCE ESPACE TECHNIQUE MINIMUM CASO B CASE B CAS B DIF P DIF A SIEF_20200507_DIF P DIF A _M 5 Terminali filtranti per ambienti a contaminazione controllata SPAZIO TECNICO MINIMO PER I...

Страница 6: ...tige filet e Terminal filter hoods for contamination controlled environments A By means of 4 M5 threaded rods screwed to the relevant bushes on the upper part of the profile 1 B Installation with bra...

Страница 7: ...ble duct at least 20 mm away from the connec tion between the plenum and the spigot See figure below Connect the plenum spigot with the flexible duct and secure it in place with a clamp Secure the cou...

Страница 8: ...cessary handle them care fully 3 Pay special attention to the gasket which must be unbroken before instal lation 4 Bring the filter still in its bag close to the cabinet 5 Open the bag and take the fi...

Страница 9: ...lter hoods for contamination controlled environments Place the fixing devices io the groove of the aluminium frame placing them about 100 mm from the corners fig 1 Tighten the filter clamps all the wa...

Страница 10: ...cate which should be kept 3 After thorough cleaning of the room switch on the ventilation system until the required class of cleanliness ac cording to ISO 14644 4 has been rea ched and maintained TIPS...

Страница 11: ...per ambienti a contaminazione controllata Optional tests Reference in ISO 14644 3 2005 Referenced in Principle Procedure Apparatus Installed filter system leak test 4 2 4 B 6 C 6 ISO 14644 2 Terminal...

Страница 12: ...qualsiasi momento senza alcun obbligo di preavviso per quanto indicato nella presente pubblicazione SagiCofim S p A reserves the right to make amendments or changes to the contents of this document at...

Отзывы: