Proc Sheet 1 02
myC-4
REMOVING / REPLACING THE BACK COVER
1/2
________________________________________________________________________________________________
Ref. SCT U38 SSC DTS 0023 – Index B - February 21, 2005
Page 5-16
4.22
Tools :
- Cross shaped screwdriver
4.23 Preliminary operation
1. Remove the battery pack (
Proc sheet 0 01
).
4.24 Removal procedure :
1. On the back cover (1), unscrew the four attachment screws (2) .
2. Press the two stop pins (3) to liberate the back cover (1)
3. Lift delicately the back cover (1) up beginning by the back side
4. Remove the board to board connector (4) on the electronic board
5. Liberate the electronic board from the back cover by pressing outside the four stop pins (4)
6. Unstuck delicately the vibrating device (6) from the back cover (1)
7. Remove the back cover (1)
4.25 Placement procedure :
1. Position the vibrating device (6) into the new back cover (1)
2. Position the electronic board in its housing
3. Connect the flex on the electronic board
4. Replace the equipped back cover in its housing by engaging top hooks first.
5. screw the attachment screw (2) with 0,1 N.m torque.
4.26 Further operations :
1. Replace the battery pack (
Proc sheet 0 01
).
Содержание MYC-4
Страница 16: ...Technical Site Documentation myC 4 Ref SCT U38 SSC DTS 0023 Index B February 21 2005 Page 2 7...
Страница 23: ...Technical Site Documentation myC 4 Ref SCT U38 SSC DTS 0023 Index B February 21 2005 Page 3 14...
Страница 29: ...Technical Site Documentation myC 4 Ref SCT U38 SSC DTS 0023 Index B February 21 2005 Page 3 20 SYMPTOM SHEETS...
Страница 40: ...Technical Site Documentation myC 4 Ref SCT U38 SSC DTS 0023 Index B February 21 2005 Page 4 31 TEST SHEET...