A three-pin relay output is available. It has a common, a normally open
contact and a normally closed contact.
Terminal block J8
Pin 1
Normally open
Pin 2
Normally closed
Pin 3
Common
Pin 4
Anti-theft switch
Pin 5
Anti-theft switch
Pin 6
Tamper switch
Pin 7
Tamper switch
Relay ratings
1 A at 30 VDC according to the safety extra low voltage requirements
(42.4 VAC max, 60 VDC max) independently of the power supply.
Tamper-switch ratings
100 mA at 12 VDC max according to the safety extra low voltage.
Anti-theft switch ratings
1 A at 30 VDC according to the safety extra low voltage requirements
(42.4 VAC max, 60 VDC max) independently of the power supply.
24
SAGEM Défense Sécurité document. Reproduction and disclosure forbidden.
SK-0000011145-05