Programming the SIGMA Reader
The Sigma reader programming is basically the same as the 500-series in that you can manually edit the
biometric control settings, network parameters, card formatting, etc.
1.
Power ON the reader. The ‘Boot Assistant’ app will launch automatically.
2.
Enter the password when prompted (factory default = 12345).
3.
Set up the Network Configuration as follows:
Choose “Ethernet”
and
“IPv4”
Static Mode:
Enter IP, Subnet, and Gateway addresses (recommended; DNS ‘OFF/disabled’).
Protocol Config:
choose “
Legacy Morpho
”
Create a new password
(recommended)
First Boot Config Storage:
(recommended) choose “
permanent
” to prevent the Boot Assistant
from launching in the event of future power failures, and needing to reconfigure reader.
Once the
storage mode
is set to “permanent”, user can open the ‘Config. Assistant’ by pressing
the [lock icon], located on the reader’s home screen. Enter the password to access settings.
4.
Exit the Boot Assistant