16

Under normal usage, the lamp life time of the projector
is about 1500 hours. The output luminance will drop as
lamp life diminishes. User can check the used lamp life
status in the MANAGEMENT MENU of OSD.

Change the lamp cartridge when the brightness is no
more acceptable. User can consult qualified agent or
manufacturer for model of lamp cartridge and purchase
new ones for replacement.

User can follow the steps below and replace the lamp
cartridge.

WARNING

* THE POWER CORD MUST BE DISCONNECTED to

prevent the danger of electric shock while user replacing
the lamp cartridge.

* DO NOT TOUCH THE LAMP immediately after it is

used. It will be extremely hot and might cause harm.

* DO NOT RELEASE ANY SCREWS except those in the

instruction below. This is to prevent user from the danger
of electric shock.

* Replacing ONLY THE SAME OR EQUIVALENT TYPE:

SAGEM SLP 504 P/N: 251394995

REPLACING THE LAMP UNIT

1. Turn off the power and disconnect the power cord.

Wait at least one hour for the lamp to cool down.

2. Turn the unit bottom up carefully and loosen the

two fixing screws on the lamp cover.

3. Remove the lamp cover and loosen the two fixing

screws on the lamp cartridge.

Handle

4. Hold the handle and pull the lamp cartridge up

carefully to remove it.

5. Install the new lamp cartridge.

Secure screws

6. Secure the new lamp cartridge with screws.

7. Secure the lamp cover with screws. Return the unit

to normal position and restart the unit. User can
reset the lamp counter (RESET LAMP) in the
management menu of OSD manually.

Содержание FLP 3000-X

Страница 1: ...r User s Manual FLP 3000 X SAGEM SA Si ge social Le ponant de Paris 27 rue Leblanc 75512 PARIS CEDEX 15 FRANCE Soci t anonyme directoire et conseil de surveillance au capital de 33 300 000 562 082 909...

Страница 2: ...A Apple Macintosh and PowerBook logo are trademarks of Microsoft Windows logo are trademarks of DLP Digital Light Processing Texas Instruments logo are trademarks of Others trademarks and trade names...

Страница 3: ...s of the Projector 03 Installation 04 Connections 05 Basic Operation 08 Using the Remote Control 11 Menu Operation OSD 12 Troubleshooting Indicators 15 Cleaning and Replacing the Air Filter 15 Replaci...

Страница 4: ...ore attempting to use the unit Before disconnecting the power cable make sure you have followed the shut off procedure Disconnect the power cable from the power outlet after using the unit If you are...

Страница 5: ...x 2 ACCESSORIES Remote control and batteries User s manual VGA cable 1 8 m 6 0ft AC power cable 1 8m 6 0ft S Video cable 1 8m 6 0ft DVI cable 1 8m 6 0ft Component YCbCr YPbPr cable 1 8m 6 0ft Not sup...

Страница 6: ...oom Ring Adjuster Legs Air Filter Lamp Cover Video S Video Audio Y Cb Pb Cr Pr DVI D RGB out Rs232 USB RGB in 2 RGB in 1 Remote Sensor Rear Cooling Fans and Ventilation Slot Connector Panel Power Sour...

Страница 7: ...ent any scraps or lint suck into ventilation slots or use the projector in the dusty environment Please do not operate the projector while the ambient temperature or the humidity is too high Please us...

Страница 8: ...e cable Accessory Audio cable Not supplied optional DVI cable Not supplied optional CONNECTIONS Connecting a computer or a notebook PC You can use the remote control as the PC mouse Desktop PC or Note...

Страница 9: ...CD DVD player Digital camcorder L R Audio VIDEO Video S Video Audio Y Cb Pb Cr Pr DVI D RGB out Rs232 USB RGB in 2 RGB in 1 Connecting a VCD DVD player digital camcorder by using a S Video cable S Vid...

Страница 10: ...onent video cable YCbCr YPbPr Component images YCbCr YPbPr Component YCbCr YPbPr cable Not supplied optional DVD player Audio cable Accessory Y Cb Pb Cr Pr L R Audio Video S Video Audio Y Cb Pb Cr Pr...

Страница 11: ...nnect the power cord and turn on the MAIN POWER switch 4 Press the POWER button 5 Turn on the connected input source 6 Press the SOURCE button to select the input signal The three indicators will flas...

Страница 12: ...adjusted automatically in accordance with the signal being input Press the button again to restore the sound A still image is displayed Press the button again to restore the image Press VOLUME remote...

Страница 13: ...off when you press the button once more The lamp will turn off and the cooling fan will keep running The POWER indicator will flash GREEN for 60 sec Be careful not to cut power to the projector while...

Страница 14: ...RCE MENU ENTER ESC LASER Caution Do not point LASER pointer to anyone s eyes or stare into beam Laser Beam Laser type Class 2 Wavelength 650nm Output 0 45 0 80 mW Mouse Keys User can use the remote co...

Страница 15: ...ss ESC You can use the ON SCREEN MENU to make various adjustments and settings MENU OPERATION OSD List of Functions IMAGE Sub menu BRIGHTNESS CONTRAST SHARPNESS POSITION SATURATION TINT PHASE Function...

Страница 16: ...AUDIO Sub menu VOLUME MUTE Function Adjust the volume Mute the sound temporarily COLOR ADVANCED Sub menu COLOR MODE COLOR TEMP RGB GAIN RGB LEVEL PATTERN INPUT Function Select a gamma color curve mod...

Страница 17: ...t the position of the logo within its area LOGO DELETE Delete the capture logo START LOGO CAPTURE Start the logo capture process Show the logo chosen by user MANAGEMENT Sub menu OSD SETTING LAMP COUNT...

Страница 18: ...r again Status Cause Remedy Flashing Lighting CLEANING AND REPLACING THE AIR FILTER The air filter must be cleaned about every 300 hours If dust accumulates too much and becomes difficult to remove by...

Страница 19: ...extremely hot and might cause harm DO NOT RELEASE ANY SCREWS except those in the instruction below This is to prevent user from the danger of electric shock Replacing ONLY THE SAME OR EQUIVALENT TYPE...

Страница 20: ...Cb RCA x 3 D Sub 15 pin x 1 PC Mac NTSC PAL SECAM 4 3 16 9 IR with mouse and Laser point 1W 1W built in speaker 39dB 320W 100 240 VAC 50 60 Hz 15 Vertical and Horizontal Digital zoom Freeze Capability...

Отзывы: