21
EN
RESET DEFAULT SETTINGS
Reset Auto Dose Time
Resetting the auto dose time is recommended
if there is a significant change to the grind size
or there is an accidental double dose into the
portafilter.
The machine must be on STANDBY mode.
• Press and hold ‘Manual Dose’ button and
‘Filter’ button for 3 seconds to reset grind time
to factory settings.
•
The machine will confirm the reset when the
control panel lights for filter, grind mode and
dial will flash 3 times with beeping sounds.
• The machine will return to STANDBY mode.
Reset Extraction Time
The machine must be on STANDBY mode.
• Press and hold the ‘Filter’ and 1 CUP and
2 CUP buttons for 3 seconds.
• The machine will beep 3 times.
• The machine will then go into ready mode on
next power on.
ALERTS
No Hopper Warning
The filter lights flash between single and double
basket size, the hopper is not attached correctly.
Check the hopper and ensure the bean hopper
is inserted correctly and locked in place.
Low Coffee Beans Warning
The ‘Dose’ button and the ‘Dose Level’ lights will
flash two red LEDS and will sound 3 beeps. Add
coffee beans to the hopper.
Tamp Lever Not at Home Position
The machine beeps 3 times and pauses dose
cycle. Return the lever to the up or home
position and press Dose button to continue.
Содержание Barista Express Impress BES876
Страница 29: ...the User Guide B S DK HURTIG VEJLEDNING the Barista Express Impress BES876 SES876...
Страница 57: ...the User Guide B S SE SNABBGUIDE BES876 SES876 the Barista Express Impress...
Страница 85: ...the User Guide B S NO HURTIGVEILEDNING the Barista Express Impress BES876 SES876...
Страница 112: ...28 Garanti...
Страница 113: ...the User Guide B S FI PIKAOPAS the Barista Express Impress BES876 SES876...
Страница 141: ...29 FI Muistiinpanoja...