Chapter 3: Wiring
Firmware – S1043
Revision: 2 (9/98)
44
© Saftronics, Inc.
3.7.2
PG Speed Option Card Terminal Blocks
The terminal specifications for each PG Speed Option Card are given in the following tables:
§
PG-A2 (For V/f with PG Feedback Mode Only)
Table 3.10
PG-A2 Terminal Specifications
Terminal
No.
Contents
Specifications
1
12 VDC(
±
5%), 200 mA maximum
2
Power Supply for pulse generator
0 VDC (GND for power supply)
3
4
+
12 V/open collector switching
terminal
Terminal for switching between 12 V voltage
input and open collector input. For open collector
input, short across 3 and 4
5
H:
+
4 to 12 V; L:
+
1 V maximum. (maximum
response frequency: 30 kHz)
6
Pulse input terminal
Pulse input common
7
12 VDC (
+
10%), 20 mA maximum
TA1
8
Pulse motor output terminal
Pulse monitor output common
TA2
(E)
Shield connection terminal
§
PG-B2 (For Flux Vector Control Mode Only)
Table 3.11
PG-B2 Terminal Specifications
Terminal
No.
Contents
Specifications
1
12 VDC(
±
5%), 200 mA maximum
2
Power Supply for pulse generator
0 VDC (GND for power supply)
3
H:
+
8 to 12 V
L:
+
1 V maximum
(maximum response frequency: 30 kHz)
4
A-Phase pulse input terminal
Pulse input common
5
H:
+
8 to 12 V
L:
+
1 V maximum
(maximum response frequency: 30 kHz)
TA1
6
B-Phase pulse input terminal
Pulse input common
1
Open collector output, 24 VDC, 30 mA maximum
2
A-Phase monitor output terminal
A-Phase monitor output common
3
Open collector output, 24 VDC, 30 mA maximum
TA2
4
B-Phase monitor output terminal
B-Phase monitor output common
TA3
(E)
Shield connection terminal
§
PG-D2 (For V/f with PG Feedback Mode Only)
Table 3.12
PG-D2 Terminal Specifications
Terminal
No.
Contents
Specifications
1
12 VDC(
±
5%), 200 mA maximum (see note)
2
0 VDC (GND for power supply)
3
Power Supply for pulse generator
5 VDC ((
±
5%), 200 mA maximum (see note)
4
Pulse input
+
terminal
5
Pulse input
−
terminal
Line driver input (RS-422 level input)
Maximum response frequency: 300 kHz
6
Common terminal
—
7
Pulse monitor output
+
terminal
TA1
8
Pulse monitor output
−
terminal
Line driver output (RS-422 level output)
TA2
(E)
Shield connection terminal
—
NOTE: