Chapter 2: Handling Inverters
Firmware – S1043
Revision: 2 (9/98)
16
© Saftronics, Inc.
2.5
Removing/Attaching the Digital Operator and Front Cover
Remove the front cover to wire the terminals.
For models of 15 kW or less (both 200 V and 400 V class), do not remove or mount the front cover without first removing the Digital
Operator; otherwise, the Digital Operator may malfunction due to imperfect contact. Use the following procedures to remove or
attach the front cover.
2.5.1
Inverters of 15 kW or Less
§
Removing the Digital Operator
Press the lever on the side of the Digital Operator in the direction of arrow 1 to unlock the Digital Operator. Lift the
Digital Operator in the direction of arrow 2 to remove the Digital Operator as shown in the following illustration.
Figure 2.2
Removing the Digital Operator
§
Removing the Front Cover
Press the left and right sides of the front cover in the directions of arrows 1 and lift the bottom of the cover in the
direction of arrow 2 to remove the front cover as shown in the following illustration.
Figure 2.3
Removing the Front Cover
§
Mounting the Front Cover
After wiring the terminals, mount the front cover to the Inverter by performing in reverse order the steps to remove
the front cover.
1. Do not mount the front cover with the Digital Operator attached to the front cover; otherwise, the Digital
Operator may malfunction due to imperfect contact.
2. Insert the tab of the upper part of the front cover into the groove of the Inverter and press the lower part of the
front cover onto the Inverter until the front cover snaps shut.