background image

 
 

 

The electrician can remove the supplied plug by the following: 
 1. Lift off the top plate and put switch 

‘A’ 

into the off position (Fig. 21). 

 

2. Ensure that the appliance is unplugged. 
3. Lift off the access cover by removing the retaining screw (Fig. 6A). 

 

4. Unscrew and remove the Live, Neutral and Earth wires (Fig. 7A).  
5. Unscrew the cable clamp (Fig. 7B) and remove the supply cord. 

 

6. The electrician can then connect the wire from the appliance to the connection box (by following the steps  
    above in reverse) ensuring that it incorporates a double pole isolating switch, having a contact separation of at  
    least 3 mm. Brown 

 Live (L), Blue 

 Neutral (N) and Green/Yellow 

 Earth (E).  

 

Содержание Magic-Fire MISTERO 500

Страница 1: ...opean Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EEC Directives 2006 95 EC and...

Страница 2: ...e product into surround enclosure 6 Commissioning initial product start up 8 Multiple product installation daisy chaining 8 Operating the product 11 Manual controls 11 Receiver controls 12 Remote cont...

Страница 3: ...ded normal opening position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less th...

Страница 4: ...ning it may result in the activation of the leak prevention valve See Changing the Leak Prevention Valve paragraph below under Maintenance for further information The water tank sump sump lid tank cap...

Страница 5: ...re above the product Fig 2 This will allow enough space above the product to allow the flame effect to form fully and not to be obstructed When determining a location for the product ensure that the u...

Страница 6: ...the effective ventilation as mentioned above will be reduced So in that case there needs to be created extra ventilation This must be taken into account in advance so that the minimum requirements for...

Страница 7: ...ining screw Fig 6A 4 Unscrew and remove the Live Neutral and Earth wires Fig 7A 5 Unscrew the cable clamp Fig 7B and remove the supply cord 6 The electrician can then connect the wire from the applian...

Страница 8: ...orrect height to suit the installation and ensure it is adequately level This can be done by adjusting the adjustable feet with a flat head screwdriver Fig 8 The levelness of the product can be verifi...

Страница 9: ...uct for the first time ensure that a full water tank has been placed on the product Remove the water tank from its location on top of the sump Fig 12A and open it by unscrewing the orange cap Fig 12B...

Страница 10: ...d when switched back on they will operate in the same state as before they were switched off Multiple Product Installation Follow steps 1 4 Installing the Product into Surround Enclosure to fit the fi...

Страница 11: ...to match the first product and ensure it is adequately level This can be done by adjusting the adjustable feet with a flat head screwdriver Fig 8 The levelness of the product can be verified by check...

Страница 12: ...conds of warm up time is required before the flame effect starts is the Pairing button This will pair your remote control to the receiver See Remote Control Operation for details is the test mode butt...

Страница 13: ...rease the height intensity of your flame You will hear an audible beep when you reach the maximum level is the reduce fire crackling sound Press this to reduce the volume of the crackling sound The mi...

Страница 14: ...will hear an audible beep when you reach the maximum level REMOTE CONTROL The remote control is supplied with 2x AAA batteries Remove the battery cover from the underside of the remote control and aft...

Страница 15: ...Press the and buttons to adjust the flame to your desired level Please give the flame generator time to react to the changes you make Once you have made your adjustments to both the flame height and c...

Страница 16: ...t draining the water from sump CLEANING Warning Always press Switch A to the OFF 0 position Fig 21 and disconnect from the power supply before cleaning the fire We recommend cleaning the following com...

Страница 17: ...trical connector to the transducers located on the right side of the sump Fig 23 5 There are two orange clips holding down the nozzle on the sump one on the left and one on the right hand side of the...

Страница 18: ...er The transducer is a consumable item and may need to be replaced through time depending on its usage Replacement transducers can be purchased from Safretti info safretti com The transducer is fixed...

Страница 19: ...ct the new Bluetooth receiver with your telephone Follow the following steps The mains switch must be in the ON I position for the appliance to operate Press on the on standby button to turn the appli...

Страница 20: ...afretti Magic Fire so the checkmark disappears to be able to connect another smartphone or tablet Additional Information AFTER SALES SERVICE Your product is guaranteed for two years from the date of p...

Страница 21: ...efilling the Water Tanks above Little or no mist generation Transducer not operating correctly Transducer is dirty Transducer is not sitting correctly in sump Fan is obstructed or blocked Nozzle is no...