Quantum™ äd
ə
s
ē
®
RFID Installation Instructions
Pg. 5 of 8
Installing the lock trim (continued)
10. Watching for the green LED on the proximity reader to flash four times, connect the battery wire to the
PCB. The green light indicates that the PCB has reset.
Important:
The battery wire should be the last connection made to the PCB.
11. With the dead bolt retracted, insert the long end of the dead bolt spindle assembly through the PCB
switch cam hole and into the mortise dead bolt hub. The indicator marks on the switch cam should be
at the right (3:00 position) when the mortise dead bolt is retracted (see Fig. 4 on the following page).
The retaining ring should rest on the switch cam when fully inserted (the proper positioning of the cam
will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is
thrown for privacy, except when emergency keycards are used). Position dead bolt spindle assembly
into cam assembly.
Important:
As illustrated in Fig. 4, be sure that the cam is in correct orientation.
12. Install the inside escutcheon with the thumb turn pointed upward.
13. Secure the inside trim cover to the inside trim using two color-matching M4 x 16mm Torx screws (see
Fig. 5 on the following page).
14. Program the lock using the Quantum RFID LPI Probe. Test the functioning of the lock as discussed in
the following section and the programming manual before closing the door. When the construction
key is used, the red and green LEDs will blink together, indicating that the time and date are not set.
© SAFLOK™
INS_QTMADESERFID
2/16/2012