background image

Quantum™ äd

ə

s

ē

® 

RFID Installation Instructions 

Pg. 5 of 8 

Installing the lock trim (continued) 

 
10.  Watching for the green LED on the proximity reader to flash four times, connect the battery wire to the 

PCB. The green light indicates that the PCB has reset. 

 

Important:

 The battery wire should be the last connection made to the PCB. 

 
11.  With the dead bolt retracted, insert the long end of the dead bolt spindle assembly through the PCB 

switch cam hole and into the mortise dead bolt hub. The indicator marks on the switch cam should be 
at the right (3:00 position) when the mortise dead bolt is retracted (see Fig. 4 on the following page). 
The retaining ring should rest on the switch cam when fully inserted (the proper positioning of the cam 
will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is 
thrown for privacy, except when emergency keycards are used). Position dead bolt spindle assembly 
into cam assembly. 

 

Important:

 As illustrated in Fig. 4, be sure that the cam is in correct orientation.  

 
12.  Install the inside escutcheon with the thumb turn pointed upward.   
 
13.  Secure the inside trim cover to the inside trim using two color-matching M4 x 16mm Torx screws (see 

Fig. 5 on the following page). 

 
14.  Program the lock using the Quantum RFID LPI Probe. Test the functioning of the lock as discussed in 

the following section and the programming manual before closing the door. When the construction 
key is used, the red and green LEDs will blink together, indicating that the time and date are not set. 

© SAFLOK™ 

INS_QTMADESERFID 

 2/16/2012 

Содержание Quantum ädesē RFID

Страница 1: ...J OR A59990 HAND G Mortise MT ADB DAJ Scalp Plate 51190 COLOR Strike Plate 30320 HAND COLOR Inside Trim Assembly QP12XXX 6 XX All information contained herein including but not limited to product pric...

Страница 2: ...dware and confirm that the existing door edge prep is appropriate for the SAFLOK mortise lock Drill fixture If you are using a SAFLOK drill fixture position and clamp the fixture on the door The fixtu...

Страница 3: ...pulled as the mortise is inserted into the pocket 4 Attach the mortise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure...

Страница 4: ...ull on the ribbon cable This hole is located above printed circuit board PCB assembly Route the motor wire through the wire channel in the inside trim closest to the door edge These holes are located...

Страница 5: ...ully inserted the proper positioning of the cam will allow the door to be opened when the dead bolt is retracted and block entry when the dead bolt is thrown for privacy except when emergency keycards...

Страница 6: ...ontinued Ribbon Connection Battery Ribbon Green Ground Wire Battery Wire Dead Bolt Spindle Assembly M4 X 16mm Torx Screws 3 00 Position ADB Mortise Motor Wire Motor Connection Route ribbon upward over...

Страница 7: ...lash refer to the table below Lock Communication Electronic Function Description Red and green LEDs flash Time and date not set use the Quantum RFID LPI probe to reset nine times simultaneously Yellow...

Страница 8: ...s used Red light flashes twice if keycard is used incorrectly and cannot be read e g a credit card is used Green light flashes when the proper keycard is used Green light is flashing when the lever is...

Отзывы: