V1.0 2021 Copyright Safewaze
V1.0 2021 Copyright Safewaze
Page 12
LOAD IN
DICATO
R
LOA
D IN
DIC
ATO
R
A
FALL-ARREST
Arc Flash
i
ANSI Z359.14, ANSI A10.32,
OSHA 1910.66, OSHA 1926.502
ASTM F887
020005
LOAD IN
DICATO
R
LOA
D IN
DIC
ATO
R
A
FALL-ARREST
Ar
c F
lash
i
AN
SI
Z359.
14,
AN
SI
A
10
.32,
OSH
A
19
10.
66,
O
SH
A 1926.
50
2
AST
M
F
88
7
0
20
00
5
Ar
c F
lash
i
ANSI
Z
359
.14,
ANS
I A10.32,
OSHA
19
10
.66
, O
SHA
1926.5
02
AST
M
F8
87
0
20
00
5
A
B
With the Dual Leg Safewaze SRL mounted on the back of a Full Body Harness, the user can have continuous fall protection (100 % tie-off) while
ascending, descending, or moving laterally (See Figure 10B)
.
With the lifeline leg of one SRL attached to an anchorage point, the worker can
move to a new location, attach the unused lifeline leg of the other SRL to another anchorage point, and then disconnect from the original anchorage
point.
IMPORTANT:
Never connect more than one person at a time to the dual-leg system.
IMPORTANT:
Do not allow the lifelines to pass under arms or between legs.
Safewaze SRLs have been tested and certified to the performance requirements of the standard(s) identified on their ID labels. See Tables 7 and 8 for
performance specifications.
4.2 DUAL LEG SRL
5.0 SPECIFICATIONS
5.1 PERFORMANCE
FIGURE 10 - SYSTEM CONNECTIONS
4.0 SYSTEM CONNECTIONS
4.1 ANCHORAGE
Select an anchorage location with minimal free fall and swing fall hazards (See Section 1.4). Select a rigid anchorage point capable of sustaining static
loads as defined in Section 1.4. Where anchoring overhead is not feasible, Safewaze Latitude Pro Arc Flash SRLs may be secured to anchorage points
up to a maximum of 2 ft. (.61 m) below the users Dorsal D-ring. NOTE: THIS ADJUSTMENT WILL ADJUST THE TOTAL FREE FALL AND MAXIMUM
ARREST DISTANCE OF A FALL.
Figure 10 illustrates some typical examples of harness and anchorage connections for Safewaze SRL Fall Arrest Systems. When using a snap
hook to make a connection, ensure roll-out cannot occur (See Figure 1). Do not use snap hooks or carabiners that will not completely close over the
anchor point. This includes traditional overhead anchor point tie off, housing attachment to dorsal D-ring, and 100% tie off. Follow the manufacturer’s
instructions supplied with each system component.
WARNING:
Never connect the snap hook of one SRL to the lifeline of another SRL or lanyard. Failure to comply with this warning
may result in equipment malfunction, serious injury or death.
WARNING:
The anchor point must be located at the same height or above the edge over which a fall might occur. Never anchor
Safewaze SRLs below user’s feet. Safewaze Pro Arc Flash series SRLs are Class A if used above Dorsal D-ring. Safewaze Pro Arc
Flash series SRLs are Class B if used up to a maximum of 2 ft (.61 m) below Dorsal D-ring. Failure to comply with this warning may
result in equipment malfunction, serious injury, or death.