User Manual
V1.0 2017 Copyright SAFEWAZE ™
Page 10
Uninstall Guide
FS807 Fall Clearance Chart
Uninstall is easily achieved by rotating the handle counter clockwise (see Figure 3) to unlock drum
assembly. With the drum assembly unlocked, press in on the ridged portion of the drum assembly
while at the same time pulling the rope through the tensioner to slacken horizontal lifeline. Once
enough slack is achieved, disconnect the tensioner and opposite end of the lifeline from anchorage
points.
Sample Image of Installed System
Uninstall Diagram
Press inward on ridged
portion of drum assembly
Rotate tension lever
counter clockwise to
unlock drum assembly
With drum assembly
depressed, pull slack in this
direction to slacken lifeline
FIGURE 3
51-60
(15.54-18.30)
25'-1"
(7.65)
30'-6"
(9.30)
31'-7"
(9.63)
SAFEWAZE Required Clearance for up to 3 Users
Maximum 60
ft
span
Fall Clearance with
6
ft
Energy Absorbing
Lanyard in feet (m)
TWO USERS
20'-9"
(6.32)
41-50
(12.50-15.24)
24'
(7.32)
28'-2"
(8.60)
30'-1"
(9.17)
Fall Clearance with
6
ft
Energy Absorbing
Lanyard in feet (m)
ONE USER
20'-1"
(6.12)
21'
(6.40)
22'-2"
(6.76)
23'-1"
(7.04)
Span Length in
Feet (m)
31-40
(9.45-12.20)
21-30
(6.40-9.14)
1-10
(.30-3.05)
11-20
(3.35-6.10)
21'-8"
(6.60)
23-6"
(7.16)
25'-9"
(7.85)
Fall Clearance with
6
ft
Energy Absorbing
Lanyard in feet (m)
THREE USERS
21'-5"
(6.53)
22'-4"
(6.81)
24'-1"
(7.34)
26'-8"