- 6 -
PARAMETER
OPTIONS
DESCRIPTION
1
SYSTEM
LANGUAGE
中文
This option controls which language should be used in the
valve display.
ENGLISH
SPANISH
2
REGIONAL OPTION
METRIC
This option controls which unit format should be displayed
in the valve display.
US
3
REGEN. MODE
CALENDAR
CLOCK
The unit will initiate a regeneration at the next pre-set
regeneration time based on the interval of days between
regeneration days.
METER
IMMEDIATE
The unit will initiate a regeneration immediately after the
volume remaining reaches zero.
METER
DELAYED
This is the most common setting. When the volume
remaining
reaches
zero,
the
system
will
initiate
a
regeneration at the next pre-set regeneration time.
METER
OVERRIDE
When the volume remaining reaches zero, the system will
initiate a regeneration at the next pre-set regeneration time.
If the days between regeneration are reached before the
volume remaining reaches zero, the system will override
the meter setting and initiate a regeneration.
4
CURRENT DATE
This setting controls the current date. The date is used to
track the last time the system regenerated.
5
CURRENT TIME
This setting controls the current time of day.
6
REGEN.
TIME
This setting controls the time of day when a regeneration
will start.
7
REGEN.
DAYS
This value is the interval (days) between regenerations. It is
used to determine how many days between regenerations
9
REGEN. CAPACITY
This value is the total capacity between regenerations. It is
used to determine how many gallons can be used between
regenerations
10
BA.WA. DURATION
This setting controls the length of time for the unit to clean
the bed by reversing the flow of water upwards through the
bed and out to the drain.
11
BRINE DURATION
This setting controls the length of time for the unit to draw
regeneration (brine for softeners) from the brine tank and
slowly rinse the media tank from the top to the bottom.
12
RINSE DURATION
This setting controls the length of time to give the tank a
final rinse from the top to the bottom in order to remove any
last traces of the regeneration from the tank.
13
REFILL DURATION
This setting controls the length of time which the brine valve
will open to refill the brine tank with water in order to
produce the salt solution for next regeneration. The water
accurately measured through the valves brine line flow
control to make a precise quantity of salt solution.
14
LOAD DEFAULT
This setting allows the current settings to be erased and
changed back to the default settings.