background image

INSTRUCTION: TempLink 5000   

REVISION: 1.0

®

Innovative

Fall Protection

Safety

Link

Temp

Link

 

5000

Temporary Roof Anchor

User Instruction

Figure 1 

Warning

 

Improper Use, Installation or Maintenance may result in serious injury or death.

 

The building or structure for the anchorages should be assessed by an engineer to 

ensure that the structure is adequate for TempLink 5000 installation works.

 

SafetyLink's Height Safety Systems must only be installed as per our installation 

guides, to structures as specified in the installation manual for each product.

 

All safety procedures must be complied with in accordance with the current safety 

code(s) of practice(s) for working at heights in your region. Ensure safety at all times by 

being attached to suitable anchor points and approved safety equipment or approved 

scaffolding.

 

Installation is to be carried out by, or under the supervision of, a competent person.

 

A personal energy absorber or a fall-arrest device with a personal energy absorber 

must be used in conjunction with all SafetyLink Anchorages and Lifeline systems.

 

Do not carry out any modifications on this system without written permission by 

SafetyLink Pty Ltd.

Содержание TempLink 5000

Страница 1: ...structures as specified in the installation manual for each product All safety procedures must be complied with in accordance with the current safety code s of practice s for working at heights in your region Ensure safety at all times by being attached to suitable anchor points and approved safety equipment or approved scaffolding Installation is to be carried out by or under the supervision of a...

Страница 2: ...e fall clearance In Figure 2 A represents the deflection TempLink 5000 300mm Max B represents free fall energy absorber deployment as well as the estimated D ring side of the harness Refer the manufacturer s information SF represents the recommended safety factor of 1m FC represents the total allowable fall clearance For safe use FC shall always be greater than A B SF Figure 2 Figure 3 B A SF FC 3...

Страница 3: ...ing which has another connector attached 2 In a position that will apply load to the gate mechanism 3 By passing the connection through the attachment 4 Connecting a connector to another connector 5 Around a structure and back to the lifeline 6 To an attachment that will limit the function of the gate 7 To a location that will not load the connector as designed 4 2 Compatibility of Connections Con...

Страница 4: ...trength of the structure Structure shall be accordance with local building codes Steel purlins shall be a minimum of 150mmx1 5mm Timber rafters shall be minimum 90x35mm with 70x45mm battens MGP10 or F7 3 Remove the existing roof sheeting screws in the area where the anchor is to be installed 4 Place the anchor on the roof and install a minimum of 5x 14 gauge screws through the mounting holes in th...

Страница 5: ... Cleaning The TempLink 5000 may be cleaned by the end user periodically to increase service life After cleaning the product shall undergo the pre use inspection Clean with a rag and warm water to remove dirt and grit A mild detergent may be used to remove grease or oils from the product Do not store this product when wet Allow the product to dry and conduct a pre use inspection prior to returning ...

Страница 6: ... 3 2 Fall Indicators inspect tabs are intact Comments 7 3 3 Screw Surface inspect for damage deformation corrosion signs of over loading twisting buckling Comments 7 3 4 Energy Absorber inspect the serpentines lay flat and inline with the product Inspect the energy absorber is free of cracks dirt debris defects damage deformation corrosion signs of over loading Comments 7 3 5 Markings inspect all ...

Страница 7: ...rgy absorber and PPE TempLink 5000 Single person Fall Arrest Anchor Complies with AS NZS 5532 2013 and EN795 2012 Multi directional 360 degree use Always read instruction handbook prior to use Fixing of TempLink 5000 1 Remove five 5 existing roof screws along the timber batten or purlin line at the location for the anchor 2 Position the TempLink 5000 to line up with the existing roofing screw hole...

Страница 8: ...rees to making good any such defects by repairing the same or at the Company s option by replacement for a period of 1 one year from the date of shipment This limited warranty applies provided that a defects have arising solely from faulty materials or workmanship b the Products have not received maltreatment inattention or interference c the Products have been installed in accordance with the Com...

Отзывы: