background image

8

9

Safety Works, Inc.

Latham, NY, 12110

888-672-4692

These respirators are approved only in the following configurations:

TC- 

  Protection

1

Retainer

 CAUTIONS AND LIMITATIONS

2

G

01

G

02

G

03

G

04

G

05

G

08

G

71

G

72

G

73

G

74

G

75

G

70

G

95

P

X

P

10

0

X

P

10

0-

O

V

/A

G

17

2

1- PROTECTION

C - Do not exceed maximum use concentrations established by regulatory standards.
H - Follow established cartridge and canister schedules or observe ESLI to ensure that
  cartridges and canister are replaced before breakthrough occurs.
J -  Failure to properly use and maintain this product could result in injury or death.
L -  Follow the manufacturer's instructions for changing cartridges and filters.

P95 - Particulate filter (95% filter efficiency level) effective against

M - All approved respirators shall be selected, fitted, used, and maintained in accordance

          all particulate aerosols.

  with MSHA, OSHA and other applicable regulations.
N - Never substitute, modify, add, and/or omit parts. Use only exact replacement parts

P100 - Particulate filter (99.97% filter efficiency level) effective against

  in the configuration as specified by the manufacturer.

            all particulate aerosols.

O - Refer to user instructions, and/or maintenance manuals for information on use and
    maintenance of the respirators.
P -  NIOSH does not evaluate respirators as surgical masks.

2 -  CAUTIONS AND LIMITATIONS

A -  Not for use in atmospheres containing less than 19.5 percent oxygen.
B -  Not for use in atmospheres immediately dangerous to life or health.

AM - AMMONIA

CD - CHLORINE DIOXIDE

CL - CHLORINE

FM - FORMALDEHYDE

HC - HYDROGEN CHLORIDE

HF - HYDROGEN FLUORIDE

HS(escape) 

    - HYDROGEN SULFIDE 

    (escape only)

HS - HYDROGEN SULFIDE

MA - METHYLAMINE

OV - ORGANIC VAPOR

SD - SULFUR DIOXIDE

Facepiece

Filter

99

50

99

00

Cartridges

84A-5498 

P100 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

ABCJLMOP

23C-2722 

OV 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2723 

SD/HC/CL/CD/HF/HS(ESCAPE) 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2724 

OV/SD/HC/CL 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2725 

AM/MA 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2726 

FM 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJKLMNO

23C-2840 

AM/CD/CL/FM/HC/HF/HS/MA/OV/SD 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJKLMNO

84A-5509 

P95/OV 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5510 

AM/CD/CL/FM/HC/HF/HS(escape) 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5511 

P95/OV/SD/HC/CL 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5512 

P95/AM/MA 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5513 

P95/FM 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJKLMNOP

84A-5415 

P100/OV 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNOP

84A-5514 

P100/SD/HC/CL/CD/HF/HS(escape) 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNOP

84A-5516 

P100/OV/SD/HC/CL 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5517 

P100/AM/MA 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5518 

P100/FM 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABCHJKLMNOP

84A-5521 

P100 

 

 

 

 

 

 

 

 

 

     

 

ABCJLMNOP

84A-6724 

P100 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

ABCJLMOP

23C-2865 

OV 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2866 

SD/HC/CL/CD/HF/HS(escape) 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2867 

OV/SD/HC/CL 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2868 

AM/MA 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2869 

FM 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJKLMNO

23C-2870 

AM/CD/CL/FM/HC/HF/HS/MA/OV/SD 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJKLMNO

84A-6735 

P95/OV 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6736 

AM/CD/CL/FM/HC/HF/HS(escape) 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6737 

P95/OV/SD/HC/CL 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6738 

P95/AM/MA 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6739 

P95/FM 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJKLMNOP

84A-6740 

P100/OV 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNOP

84A-6741 

P100/SD/HC/CL/CD/HF/HS(escape) 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNOP

84A-6742 

P100/OV/SD/HC/CL 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6743 

P100/AM/MA 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6744 

P100/FM 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABCHJKLMNOP

84A-6747 

P100 

 

 

 

 

 

 

 

 

 

     

 

ABCJLMNOP

S - Special or critical User’s Instructions and/or specific use limitaions apply. 

  Refer to User’s Instructions before donning.

Safety Works, Inc.

Latham, NY, 12110

888-672-4692

These respirators are approved only in the following configurations:

TC- 

  Protection

1

Retainer

 CAUTIONS AND LIMITATIONS

2

G

01

G

02

G

03

G

04

G

05

G

08

G

71

G

72

G

73

G

74

G

75

G

70

G

95

P

X

P

10

0

X

P

10

0-

O

V

/A

G

17

2

1- PROTECTION

C - Do not exceed maximum use concentrations established by regulatory standards.
H - Follow established cartridge and canister schedules or observe ESLI to ensure that
  cartridges and canister are replaced before breakthrough occurs.
J -  Failure to properly use and maintain this product could result in injury or death.
L -  Follow the manufacturer's instructions for changing cartridges and filters.

P95 - Particulate filter (95% filter efficiency level) effective against

M - All approved respirators shall be selected, fitted, used, and maintained in accordance

          all particulate aerosols.

  with MSHA, OSHA and other applicable regulations.
N - Never substitute, modify, add, and/or omit parts. Use only exact replacement parts

P100 - Particulate filter (99.97% filter efficiency level) effective against

  in the configuration as specified by the manufacturer.

            all particulate aerosols.

O - Refer to user instructions, and/or maintenance manuals for information on use and
    maintenance of the respirators.
P -  NIOSH does not evaluate respirators as surgical masks.

2 -  CAUTIONS AND LIMITATIONS

A -  Not for use in atmospheres containing less than 19.5 percent oxygen.
B -  Not for use in atmospheres immediately dangerous to life or health.

AM - AMMONIA

CD - CHLORINE DIOXIDE

CL - CHLORINE

FM - FORMALDEHYDE

HC - HYDROGEN CHLORIDE

HF - HYDROGEN FLUORIDE

HS(escape) 

    - HYDROGEN SULFIDE 

    (escape only)

HS - HYDROGEN SULFIDE

MA - METHYLAMINE

OV - ORGANIC VAPOR

SD - SULFUR DIOXIDE

Facepiece

Filter

99

50

99

00

Cartridges

84A-5498 

P100 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

ABCJLMOP

23C-2722 

OV 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2723 

SD/HC/CL/CD/HF/HS(ESCAPE) 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2724 

OV/SD/HC/CL 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2725 

AM/MA 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2726 

FM 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJKLMNO

23C-2840 

AM/CD/CL/FM/HC/HF/HS/MA/OV/SD 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJKLMNO

84A-5509 

P95/OV 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5510 

AM/CD/CL/FM/HC/HF/HS(escape) 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5511 

P95/OV/SD/HC/CL 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5512 

P95/AM/MA 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5513 

P95/FM 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJKLMNOP

84A-5415 

P100/OV 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNOP

84A-5514 

P100/SD/HC/CL/CD/HF/HS(escape) 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNOP

84A-5516 

P100/OV/SD/HC/CL 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5517 

P100/AM/MA 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-5518 

P100/FM 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABCHJKLMNOP

84A-5521 

P100 

 

 

 

 

 

 

 

 

 

     

 

ABCJLMNOP

84A-6724 

P100 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

ABCJLMOP

23C-2865 

OV 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2866 

SD/HC/CL/CD/HF/HS(escape) 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2867 

OV/SD/HC/CL 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2868 

AM/MA 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNO

23C-2869 

FM 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJKLMNO

23C-2870 

AM/CD/CL/FM/HC/HF/HS/MA/OV/SD 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJKLMNO

84A-6735 

P95/OV 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6736 

AM/CD/CL/FM/HC/HF/HS(escape) 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6737 

P95/OV/SD/HC/CL 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6738 

P95/AM/MA 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6739 

P95/FM 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJKLMNOP

84A-6740 

P100/OV 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNOP

84A-6741 

P100/SD/HC/CL/CD/HF/HS(escape) 

 

 

 

 

 

 

 

 

     

 

 

 

ABCHJLMNOP

84A-6742 

P100/OV/SD/HC/CL 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6743 

P100/AM/MA 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

ABCHJLMNOP

84A-6744 

P100/FM 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ABCHJKLMNOP

84A-6747 

P100 

 

 

 

 

 

 

 

 

 

     

 

ABCJLMNOP

S - Special or critical User’s Instructions and/or specific use limitaions apply. 

  Refer to User’s Instructions before donning.

 SPECIAL INSTRUCTIONS

The model 9900 full facepiece respirator with G01 cartridge has been manufactured for Safety Works by Louis M. 

Gerson Co. under approval TC-23C-2722

The model 9900 full facepiece respirator with G03 cartridge has been manufactured for Safety Works by Louis M. 

Gerson Co. under approval TC-23C-2724

The model 9900 full facepiece respirator with G01 cartridge with the G95P filter has been manufactured for Safety 

Works by Louis M. Gerson Co. under approval TC-84A-5509

The model 9900 full facepiece respirator with G03 cartridge with the G95P filter has been manufactured for Safety 

Works by Louis M. Gerson Co. under approval TC-84A-5511

The model 9900 full facepiece respirator with XP100 cartridge has been manufactured for Safety Works by Louis M. 

Gerson Co. under approval TC-84A-5521

These respirators are approved only in the following configurations:

TC- 

  Protection

1

Retainer

 CAUTIONS AND LIMITATIONS

2

9100

9200

9300

9900

G01

G03

G08

G71

G73

G78

GX70

G95P

XP100

XP100-OV/AG

172

23C-1578

OV/SD/HC/CL

X X X

X

84A-6809

P100

X X X

X

84A-3173

P100

X X X

X X

23C-1526

OV 

X X X

X

23C-2839

AM/CD/CL/FM/HC/HF/HS/MA/OV/SD

X X X

X

84A-3332

P95/OV

X X X

X

X

X

84A-3334

P95/OV/SD/HC/CL

X X X

X

X

X

84A-2734

 P100/OV

X X X

X

84A-2735

 P100/OV/SD/HC/CL

X X X

X

84A-6760

P100/AM/CD/CL/FM/HC/HF/HS/MA/OV/SD

X X X

X

84A-6807

P100

X

X

23C-2722

OV 

X X

23C-2724

OV/SD/HC/CL

X

X

23C-2840

AM/CD/CL/FM/HC/HF/HS/MA/OV/SD

X

X

84A-5509

P95/OV

X X

X

X

84A-5511

P95/OV/SD/HC/CL

X

X

X

X

84A-5515

P100/OV

X

X

84A-5516

P100/OV/SD/HC/CL

X

X

84A-6967

P100/AM/CD/CL/FM/HC/HF/HS/MA/OV/SD

X

X

84A-5521

P100

X

X X

1- PROTECTION

P95 - Particulate filter ( 95% filter efficiency level ) effective against

       all particulate aerosols.

P100 - Particulate filter ( 99.97% filter efficiency level ) effective against

       all particulate aerosols.

AM - AMMONIA

HF - HYDROGEN FLUORIDE

CD - CHLORINE DIOXIDE

HS - HYDROGEN SULFIDE 

CL - CHLORINE

MA - METHYLAMINE

FM - FORMALDEHYDE

OV - ORGANIC VAPOR

HC - HYDROGEN CHLORIDE

SD - SULPHUR DIOXIDE

2- CAUTIONS AND LIMITATIONS

A - Not for use in atmospheres containing less than 19.5 percent oxygen.

B - Not for use in atmospheres immediately dangerous to life or health.

C - Do not exceed maximum use concentrations established by regulatory standards.

H - Follow established cartridge and canister schedules or observe ESLI to ensure that cartridges and canister are replaced before breakthrough occurs.

J - Failure to properly use and maintain this product could result in injury or death.

K - The Occupational Safety and Health Administration regulations require gas-proof goggles be worn with this respirator when used against formaldehyde

L - Follow the manufacturer's instructions for changing cartridges and filters.

M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA and other applicable regulations.

N - Never substitute, modify, add, and, or omit parts.  Use only exact replacement parts in the configuration as specified by the manufacturer.

O - Refer to user instructions, and/or maintenance manuals for information on use and maintenance of the respirators.

P - NIOSH does not evaluate respirators as surgical masks

S - Special or Critical User Instructions and/or specific use limitations apply.

     Refer to User's Instructions before donning.

ABCHJKLMNOPS

ABCHJLMNOPS

ABCHJLMNOPS

ABCHJLMNOPS

Safety Works, Inc.

968 Albany Shaker Road

Latham, NY  12110

888-672-4692

ABCHJLMNOPS

ABCHJLKMNOS

ABCHJLMNOS

ABCJLMNOPS

Facepiece

Filter

Cartridges

ABCHJLMNOS

ABCJLMNOPS

ABCJLMNOPS

ABCHJLMNOS

ABCJLMNOPS

ABCHJLMNOPS

ABCHJLMNOPS

ABCHJLMNOPS

ABCHJLMNOPS

ABCHJLMNOPS

ABCHJKLMNOS

ABCHJLMNOS

The model 9900 full facepiece respirator withXP100 OV/AG cartridge has been manufactured for Safety Works by Louis 

M. Gerson Co. under approval TC-84A-5521

The model 9900 full facepiece respirator with G71 cartridge has been manufactured for Safety Works by Louis M. 

Gerson Co. under approval TC-84A-5515

The model 9900 full facepiece respirator with G73 cartridge has been manufactured for Safety Works by Louis M. 

Gerson Co. under approval TC-84A-5516

The model 9900 full facepiece respirator with G08 cartridge has been manufactured for Safety Works by Louis M. 

Gerson Co. under approval TC-23C-2840

The model 9900 full facepiece respirator with GX70 filter has been manufactured for Safety Works by Louis M. Gerson 

Co. under approval TC-84A-6807

The model 9900 full facepiece respirator with G78 cartridge has been manufactured for Safety Works by Louis M. 

Gerson Co. under approval TC-84A-6967

2 - CAUTIONS AND LIMITATIONS

A  -  Not for use in atmospheres containing less than 19.5 percent 

oxygen.

B  -  Not for use in atmospheres immediately dangerous to life or 

health.

C -  Do not exceed maximum use concentrations established by 

regulatory standards.

H -  Follow established cartridge and canister schedules or observe 

ESLI to ensure that cartridges and canister are replaced before 

breakthrough occurs.

J  -  Failure to properly use and maintain this product could result in 

injury or death.

L  -  Follow the manufacturer’s instructions for changing cartridges and 

filters.

M -  All approved respirators shall be selected, fitted, used, and 

maintained in accordance with MSHA, OSHA, and other 

applicable regulations.

N -  Never substitute, modify, add, or omit parts. Use only exact 

replacement parts in the configurations as specified by the 

manufacturer.

O -  Refer to User’s Instructions, and/or maintenance manuals for 

information on use and maintenance of these respirators.

P  -  NIOSH does not evaluate respirators for use as surgical masks.

S  -  Special or critical User’s Instructions and/or specific use 

Содержание 9900

Страница 1: ... remplaçables Máscara completa Con cartuchos y filtros reemplazables Instructions for Use and Maintenance Including NIOSH Approval Label Instructions d utilisation et d entretien Comprend l étiquette d approbation NIOSH Instrucciones para uso y mantenimiento Incluye la etiqueta de aprobación NIOSH 9900 ...

Страница 2: ... heats of reaction 4 Sandblasting 5 Oil based mists with N filters WARNING TO USER 1 Follow all instructions and warnings on the use of this respirator and wear during all times of exposure Failure to do so will reduce respirator effectiveness wearer protection and may result in sickness or death 2 For proper use ask your supervisor 3 The user must first be trained by the employer in proper respir...

Страница 3: ...ylamine chlorine chlorine dioxide hydrogen chloride hydrogen fluoride hydrogen sulfide sulfur dioxide formaldehyde and organic vapors P100 Particulate Filter against all particulate aerosols SIGNATURE SELECT STACKED CARTRIDGES XP100 P100 Particulate Pancake Filter 99 97 filter efficiency level effective against all particulate aerosols XP100 OV AG P100 Particulate Pancake Filter 99 97 filter effic...

Страница 4: ...ational Standards for Respiratory Protection ANSI Z88 2 2015 Fit tests should be performed annually or more frequently if dental surgery weight change or other factors occur which may affect the respirator fit Positive Negative Facefit Check Conduct a positive and a negative facefit check each time the respirator is worn Positive Pressure Facefit Check Place palm of hand over exhalation valve cove...

Страница 5: ...spirators are approved only in the following configurations TC Protection1 Retainer CAUTIONS AND LIMITATIONS2 9100 9200 9300 9900 G01 G03 G08 G71 G73 G78 GX70 G95P XP100 XP100 OV AG 172 23C 1578 OV SD HC CL X X X X 84A 6809 P100 X X X X 84A 3173 P100 X X X X X 23C 1526 OV X X X X 23C 2839 AM CD CL FM HC HF HS MA OV SD X X X X 84A 3332 P95 OV X X X X X X 84A 3334 P95 OV SD HC CL X X X X X X 84A 273...

Страница 6: ...s gaz ou les émanations ayant de faibles propriétés d avertissement ou qui génèrent de hautes températures de réaction 4 Sablage 5 Embruns huileux avec filtres N AVERTISSEMENT POUR L UTILISATEUR 1 Suivez tous les avertissements et les instructions d utilisation de ce respirateur et portez le pendant toute la période d exposition Le non respect de cette consigne réduira l efficacité du respirateur ...

Страница 7: ... organiques le bioxyde de soufre le chlorure d hydrogène le chlore et le fluorure d hydrogène jusqu à 50 fois la limite d exposition admissible PEL ou la limite OSHA si cette dernière est inférieure P100 Filtre à particules efficace contre tous les aérosols particulaires SIGNATURE SELECT FILTRES ET PORTE FILTRE G95P P95 Filtre plat à particules niveau d efficacité du filtre de 95 efficace contre t...

Страница 8: ...ues qui empêchent un contact direct entre votre visage et le bord du respirateur Ne portez pas de lunettes autres que celles approuvées pour le respirateur complet avec pièce faciale Safety Works Instructions d entretien d assemblage et d entreposage A Désassemblage 1 Enlevez les cartouches et ou les filtres 2 Désassemblez le harnais en enlevant les boucles de la pièce faciale 3 Enlevez le demi ma...

Страница 9: ...tors shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add and or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to user instructions and or maintenance manuals for information on use and maintenance of the respirators P NIOSH does not evaluate respirators a...

Страница 10: ...ales correspondientes 3 Gases o vapores con propiedades de advertencia deficientes o aquellos que generen un gran calor de reacción 4 Limpieza con chorro de arena 5 Neblina a base de aceite con filtros N ADVERTENCIA PARA EL USUARIO 1 Siga todas las instrucciones y advertencias acerca del uso de este respirador y úselo en todo momento que esté expuesto No cumplir con esto reducirá la efectividad de...

Страница 11: ...lado efectivo contra todos los aerosoles de material particulado SIGNATURE SELECT FILTROS Y SUJETADORES G95P P95 Filtro de disco plano para material particulado nivel de eficiencia del filtro de un 95 efectivo contra todos los aerosoles de material particulado 172 Sujetador de filtro Listado de productos MÁSCARA COMPLETA 9900 Máscara completa de elastómeros termoplásticos TPE CARTUCHOS SIGNATURE S...

Страница 12: ... física que pueda evitar el contacto directo entre la cara y el borde del respirador No use anteojos que no estén aprobados para el respirador de máscara completa de Safety Works Instrucciones de mantenimiento montaje y almacenamiento A Desmontaje 1 Quite los cartuchos y los filtros 2 Retire las hebillas de la máscara para desmontar el arnés 3 Retire la copa para nariz 4 Destornille el anillo de s...

Страница 13: ...llow the manufacturer s instructions for changing cartridges and filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add and or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to user instructions and or maintenance manuals fo...

Страница 14: ...26 27 Notes Notes ...

Страница 15: ...81644 Rev 2 1608 SAFETY WORKS Safety Works Inc 968 Albany Shaker Rd Latham NY 12110 www SafetyWorks com ...

Отзывы: