These respirators are approved only in the following configurations:
TC-
Protection
1
Retainer
CAUTIONS AND LIMITATIONS
2
G
01
G
02
G
03
G
04
G
05
G
08
G
71
G
72
G
73
G
74
G
75
G
70
G
95
P
X
P
10
0
X
P
10
0-
O
V
/A
G
17
2
1- PROTECTION
C - Do not exceed maximum use concentrations established by regulatory standards.
H - Follow established cartridge and canister schedules or observe ESLI to ensure that
cartridges and canister are replaced before breakthrough occurs.
J - Failure to properly use and maintain this product could result in injury or death.
L - Follow the manufacturer's instructions for changing cartridges and filters.
P95 - Particulate filter (95% filter efficiency level) effective against
M - All approved respirators shall be selected, fitted, used, and maintained in accordance
all particulate aerosols.
with MSHA, OSHA and other applicable regulations.
N - Never substitute, modify, add, and/or omit parts. Use only exact replacement parts
P100 - Particulate filter (99.97% filter efficiency level) effective against
in the configuration as specified by the manufacturer.
all particulate aerosols.
O - Refer to user instructions, and/or maintenance manuals for information on use and
maintenance of the respirators.
P - NIOSH does not evaluate respirators as surgical masks.
2 - CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
AM - AMMONIA
CD - CHLORINE DIOXIDE
CL - CHLORINE
FM - FORMALDEHYDE
HC - HYDROGEN CHLORIDE
HF - HYDROGEN FLUORIDE
HS(escape)
- HYDROGEN SULFIDE
(escape only)
HS - HYDROGEN SULFIDE
MA - METHYLAMINE
OV - ORGANIC VAPOR
SD - SULFUR DIOXIDE
Facepiece
Filter
99
50
99
00
Cartridges
84A-5498
P100
X
X
ABCJLMOP
23C-2722
OV
X
X
ABCHJLMNO
23C-2723
SD/HC/CL/CD/HF/HS(ESCAPE)
X
X
ABCHJLMNO
23C-2724
OV/SD/HC/CL
X
X
ABCHJLMNO
23C-2725
AM/MA
X
X
ABCHJLMNO
23C-2726
FM
X
X
ABCHJKLMNO
23C-2840
AM/CD/CL/FM/HC/HF/HS/MA/OV/SD
X
X
ABCHJKLMNO
84A-5509
P95/OV
X
X
X
X
ABCHJLMNOP
84A-5510
AM/CD/CL/FM/HC/HF/HS(escape)
X
X
X
X
ABCHJLMNOP
84A-5511
P95/OV/SD/HC/CL
X
X
X
X
ABCHJLMNOP
84A-5512
P95/AM/MA
X
X
X
X
ABCHJLMNOP
84A-5513
P95/FM
X
X
X
X
ABCHJKLMNOP
84A-5415
P100/OV
X
X
ABCHJLMNOP
84A-5514
P100/SD/HC/CL/CD/HF/HS(escape)
X
X
ABCHJLMNOP
84A-5516
P100/OV/SD/HC/CL
X
X
ABCHJLMNOP
84A-5517
P100/AM/MA
X
X
ABCHJLMNOP
84A-5518
P100/FM
X
X
ABCHJKLMNOP
84A-5521
P100
X
X
X
ABCJLMNOP
84A-6724
P100
X
X
ABCJLMOP
23C-2865
OV
X
X
ABCHJLMNO
23C-2866
SD/HC/CL/CD/HF/HS(escape)
X
X
ABCHJLMNO
23C-2867
OV/SD/HC/CL
X
X
ABCHJLMNO
23C-2868
AM/MA
X
X
ABCHJLMNO
23C-2869
FM
X
X
ABCHJKLMNO
23C-2870
AM/CD/CL/FM/HC/HF/HS/MA/OV/SD
X
X
ABCHJKLMNO
84A-6735
P95/OV
X
X
X
X
ABCHJLMNOP
84A-6736
AM/CD/CL/FM/HC/HF/HS(escape)
X
X
X
X
ABCHJLMNOP
84A-6737
P95/OV/SD/HC/CL
X
X
X
X
ABCHJLMNOP
84A-6738
P95/AM/MA
X
X
X
X
ABCHJLMNOP
84A-6739
P95/FM
X
X
X
X
ABCHJKLMNOP
84A-6740
P100/OV
X
X
ABCHJLMNOP
84A-6741
P100/SD/HC/CL/CD/HF/HS(escape)
X
X
ABCHJLMNOP
84A-6742
P100/OV/SD/HC/CL
X
X
ABCHJLMNOP
84A-6743
P100/AM/MA
X
X
ABCHJLMNOP
84A-6744
P100/FM
X
X
ABCHJKLMNOP
84A-6747
P100
X
X
X
ABCJLMNOP
S - Special or critical User’s Instructions and/or specific use limitaions apply.
Refer to User’s Instructions before donning.
Safety Works, Inc.
Latham, NY, 12110
888-672-4692
These respirators are approved only in the following configurations:
TC-
Protection
1
Retainer
CAUTIONS AND LIMITATIONS
2
G
01
G
02
G
03
G
04
G
05
G
08
G
71
G
72
G
73
G
74
G
75
G
70
G
95
P
X
P
10
0
X
P
10
0-
O
V
/A
G
17
2
1- PROTECTION
C - Do not exceed maximum use concentrations established by regulatory standards.
H - Follow established cartridge and canister schedules or observe ESLI to ensure that
cartridges and canister are replaced before breakthrough occurs.
J - Failure to properly use and maintain this product could result in injury or death.
L - Follow the manufacturer's instructions for changing cartridges and filters.
P95 - Particulate filter (95% filter efficiency level) effective against
M - All approved respirators shall be selected, fitted, used, and maintained in accordance
all particulate aerosols.
with MSHA, OSHA and other applicable regulations.
N - Never substitute, modify, add, and/or omit parts. Use only exact replacement parts
P100 - Particulate filter (99.97% filter efficiency level) effective against
in the configuration as specified by the manufacturer.
all particulate aerosols.
O - Refer to user instructions, and/or maintenance manuals for information on use and
maintenance of the respirators.
P - NIOSH does not evaluate respirators as surgical masks.
2 - CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
AM - AMMONIA
CD - CHLORINE DIOXIDE
CL - CHLORINE
FM - FORMALDEHYDE
HC - HYDROGEN CHLORIDE
HF - HYDROGEN FLUORIDE
HS(escape)
- HYDROGEN SULFIDE
(escape only)
HS - HYDROGEN SULFIDE
MA - METHYLAMINE
OV - ORGANIC VAPOR
SD - SULFUR DIOXIDE
Facepiece
Filter
99
50
99
00
Cartridges
84A-5498
P100
X
X
ABCJLMOP
23C-2722
OV
X
X
ABCHJLMNO
23C-2723
SD/HC/CL/CD/HF/HS(ESCAPE)
X
X
ABCHJLMNO
23C-2724
OV/SD/HC/CL
X
X
ABCHJLMNO
23C-2725
AM/MA
X
X
ABCHJLMNO
23C-2726
FM
X
X
ABCHJKLMNO
23C-2840
AM/CD/CL/FM/HC/HF/HS/MA/OV/SD
X
X
ABCHJKLMNO
84A-5509
P95/OV
X
X
X
X
ABCHJLMNOP
84A-5510
AM/CD/CL/FM/HC/HF/HS(escape)
X
X
X
X
ABCHJLMNOP
84A-5511
P95/OV/SD/HC/CL
X
X
X
X
ABCHJLMNOP
84A-5512
P95/AM/MA
X
X
X
X
ABCHJLMNOP
84A-5513
P95/FM
X
X
X
X
ABCHJKLMNOP
84A-5415
P100/OV
X
X
ABCHJLMNOP
84A-5514
P100/SD/HC/CL/CD/HF/HS(escape)
X
X
ABCHJLMNOP
84A-5516
P100/OV/SD/HC/CL
X
X
ABCHJLMNOP
84A-5517
P100/AM/MA
X
X
ABCHJLMNOP
84A-5518
P100/FM
X
X
ABCHJKLMNOP
84A-5521
P100
X
X
X
ABCJLMNOP
84A-6724
P100
X
X
ABCJLMOP
23C-2865
OV
X
X
ABCHJLMNO
23C-2866
SD/HC/CL/CD/HF/HS(escape)
X
X
ABCHJLMNO
23C-2867
OV/SD/HC/CL
X
X
ABCHJLMNO
23C-2868
AM/MA
X
X
ABCHJLMNO
23C-2869
FM
X
X
ABCHJKLMNO
23C-2870
AM/CD/CL/FM/HC/HF/HS/MA/OV/SD
X
X
ABCHJKLMNO
84A-6735
P95/OV
X
X
X
X
ABCHJLMNOP
84A-6736
AM/CD/CL/FM/HC/HF/HS(escape)
X
X
X
X
ABCHJLMNOP
84A-6737
P95/OV/SD/HC/CL
X
X
X
X
ABCHJLMNOP
84A-6738
P95/AM/MA
X
X
X
X
ABCHJLMNOP
84A-6739
P95/FM
X
X
X
X
ABCHJKLMNOP
84A-6740
P100/OV
X
X
ABCHJLMNOP
84A-6741
P100/SD/HC/CL/CD/HF/HS(escape)
X
X
ABCHJLMNOP
84A-6742
P100/OV/SD/HC/CL
X
X
ABCHJLMNOP
84A-6743
P100/AM/MA
X
X
ABCHJLMNOP
84A-6744
P100/FM
X
X
ABCHJKLMNOP
84A-6747
P100
X
X
X
ABCJLMNOP
S - Special or critical User’s Instructions and/or specific use limitaions apply.
Refer to User’s Instructions before donning.
SPECIAL INSTRUCTIONS
The model 9900 full facepiece respirator with G01 cartridge has been manufactured for Safety Works by Louis M.
Gerson Co. under approval TC-23C-2722
The model 9900 full facepiece respirator with G03 cartridge has been manufactured for Safety Works by Louis M.
Gerson Co. under approval TC-23C-2724
The model 9900 full facepiece respirator with G01 cartridge with the G95P filter has been manufactured for Safety
Works by Louis M. Gerson Co. under approval TC-84A-5509
The model 9900 full facepiece respirator with G03 cartridge with the G95P filter has been manufactured for Safety
Works by Louis M. Gerson Co. under approval TC-84A-5511
The model 9900 full facepiece respirator with XP100 cartridge has been manufactured for Safety Works by Louis M.
Gerson Co. under approval TC-84A-5521
These respirators are approved only in the following configurations:
TC-
Protection
1
Retainer
CAUTIONS AND LIMITATIONS
2
9100
9200
9300
9900
G01
G03
G08
G71
G73
G78
GX70
G95P
XP100
XP100-OV/AG
172
23C-1578
OV/SD/HC/CL
X X X
X
84A-6809
P100
X X X
X
84A-3173
P100
X X X
X X
23C-1526
OV
X X X
X
23C-2839
AM/CD/CL/FM/HC/HF/HS/MA/OV/SD
X X X
X
84A-3332
P95/OV
X X X
X
X
X
84A-3334
P95/OV/SD/HC/CL
X X X
X
X
X
84A-2734
P100/OV
X X X
X
84A-2735
P100/OV/SD/HC/CL
X X X
X
84A-6760
P100/AM/CD/CL/FM/HC/HF/HS/MA/OV/SD
X X X
X
84A-6807
P100
X
X
23C-2722
OV
X X
23C-2724
OV/SD/HC/CL
X
X
23C-2840
AM/CD/CL/FM/HC/HF/HS/MA/OV/SD
X
X
84A-5509
P95/OV
X X
X
X
84A-5511
P95/OV/SD/HC/CL
X
X
X
X
84A-5515
P100/OV
X
X
84A-5516
P100/OV/SD/HC/CL
X
X
84A-6967
P100/AM/CD/CL/FM/HC/HF/HS/MA/OV/SD
X
X
84A-5521
P100
X
X X
1- PROTECTION
P95 - Particulate filter ( 95% filter efficiency level ) effective against
all particulate aerosols.
P100 - Particulate filter ( 99.97% filter efficiency level ) effective against
all particulate aerosols.
AM - AMMONIA
HF - HYDROGEN FLUORIDE
CD - CHLORINE DIOXIDE
HS - HYDROGEN SULFIDE
CL - CHLORINE
MA - METHYLAMINE
FM - FORMALDEHYDE
OV - ORGANIC VAPOR
HC - HYDROGEN CHLORIDE
SD - SULPHUR DIOXIDE
2- CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent oxygen.
B - Not for use in atmospheres immediately dangerous to life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
H - Follow established cartridge and canister schedules or observe ESLI to ensure that cartridges and canister are replaced before breakthrough occurs.
J - Failure to properly use and maintain this product could result in injury or death.
K - The Occupational Safety and Health Administration regulations require gas-proof goggles be worn with this respirator when used against formaldehyde
L - Follow the manufacturer's instructions for changing cartridges and filters.
M - All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA and other applicable regulations.
N - Never substitute, modify, add, and, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O - Refer to user instructions, and/or maintenance manuals for information on use and maintenance of the respirators.
P - NIOSH does not evaluate respirators as surgical masks
S - Special or Critical User Instructions and/or specific use limitations apply.
Refer to User's Instructions before donning.
ABCHJKLMNOPS
ABCHJLMNOPS
ABCHJLMNOPS
ABCHJLMNOPS
Safety Works, Inc.
968 Albany Shaker Road
Latham, NY 12110
888-672-4692
ABCHJLMNOPS
ABCHJLKMNOS
ABCHJLMNOS
ABCJLMNOPS
Facepiece
Filter
Cartridges
ABCHJLMNOS
ABCJLMNOPS
ABCJLMNOPS
ABCHJLMNOS
ABCJLMNOPS
ABCHJLMNOPS
ABCHJLMNOPS
ABCHJLMNOPS
ABCHJLMNOPS
ABCHJLMNOPS
ABCHJKLMNOS
ABCHJLMNOS
The model 9900 full facepiece respirator withXP100 OV/AG cartridge has been manufactured for Safety Works by Louis
M. Gerson Co. under approval TC-84A-5521
The model 9900 full facepiece respirator with G71 cartridge has been manufactured for Safety Works by Louis M.
Gerson Co. under approval TC-84A-5515
The model 9900 full facepiece respirator with G73 cartridge has been manufactured for Safety Works by Louis M.
Gerson Co. under approval TC-84A-5516
The model 9900 full facepiece respirator with G08 cartridge has been manufactured for Safety Works by Louis M.
Gerson Co. under approval TC-23C-2840
The model 9900 full facepiece respirator with GX70 filter has been manufactured for Safety Works by Louis M. Gerson
Co. under approval TC-84A-6807
The model 9900 full facepiece respirator with G78 cartridge has been manufactured for Safety Works by Louis M.
Gerson Co. under approval TC-84A-6967
2 - CAUTIONS AND LIMITATIONS
A - Not for use in atmospheres containing less than 19.5 percent
oxygen.
B - Not for use in atmospheres immediately dangerous to life or
health.
C - Do not exceed maximum use concentrations established by
regulatory standards.
H - Follow established cartridge and canister schedules or observe
ESLI to ensure that cartridges and canister are replaced before
breakthrough occurs.
J - Failure to properly use and maintain this product could result in
injury or death.
L - Follow the manufacturer’s instructions for changing cartridges and
filters.
M - All approved respirators shall be selected, fitted, used, and
maintained in accordance with MSHA, OSHA, and other
applicable regulations.
N - Never substitute, modify, add, or omit parts. Use only exact
replacement parts in the configurations as specified by the
manufacturer.
O - Refer to User’s Instructions, and/or maintenance manuals for
information on use and maintenance of these respirators.
P - NIOSH does not evaluate respirators for use as surgical masks.
S - Special or critical User’s Instructions and/or specific use