Warning and Limitations .........................................................................3, 4 & 5
NIOSH Approvals .........................................................................................6 & 7
Product Selection Guide..............................................................................8 & 9
Replacement Parts Illustration ..........................................................................10
Product Listing ................................................................................................... 11
Instructions for Use ...........................................................................................12
Inspection Procedure.........................................................................................13
Fitting Instructions .............................................................................................14
Positive/Negative Face Fit Check.......................................................................14
Maintenance, Assembly and Storage Instructions ..........................................15

WARNING:

All instructions must be read and understood before using any respirator. 

This respirator must be used with the appropriate chemical cartridges or 

cartridges with filters to protect against only those contaminants identified 

on the cartridge label or NIOSH approval label.  

All instructions pertaining to these filters and cartridges must be read 

prior to use. Adhere to all warnings, applications and limitations and to 

maintenance requirements and storage.

Improper use or selection of this on any respirator may result in injury 

or death. Before using, consult your supervisor, industrial hygienist 

or occupational safety professional to determine its suitability for your 

intended use.

IMPORTANT NOTICE TO PURCHASER

The following warranty is made in lieu of all other warranties expressed 

or implied, including but not limited to, the implied warranties of 

merchantability and fitness for purpose.

Manufacturer warrants this product to be free from defects. Manufacturer’s 

only obligation shall be, at our option, to replace any portion proving 

defective or to refund the purchase price thereof. 

USER SHALL DETERMINE 

THE SUITABILITY OF THE PRODUCT FOR HIS INTENDED USE, AND ASSUME 

ALL RISKS AND LIABILITIES IN CONNECTION THEREWITH.

WARNINGS & LIMITATIONS

IMPORTANT NOTICE TO USERS

You are responsible to understand and follow all warnings, restrictions and other information 
contained in this instruction manual before you enter a contaminated work area. Failure to do so 
may result in sickness or death.

USE AGAINST

1.  Contaminants specified on NIOSH approval label, matrix, cartridges or filters and in accordance 

with all limitations and applicable safety and health regulations, including OSHA.

2.  Contaminants with good warning properties, i.e., smell, taste or irritation.

DO NOT USE AGAINST

1.  Concentrations of contaminants which are unknown, or are immediately dangerous to life or 

health.

2.  Concentrations of contaminants which exceed the maximum use concentration or 50X the OSHA 

Permissible Exposure Limit (PEL), or according to applicable government regulations.

3.  Gases or vapors with poor warning properties or those which generate high heats of reaction.
4.  Sandblasting.
5.  Oil-based mists with N filters.

WARNING TO USER

1.  Follow all instructions and warnings on the use of this respirator and wear during all times of 

exposure. Failure to do so will reduce respirator effectiveness, wearer protection, and 

may result 

in sickness or death.

2.  For proper use, ask your supervisor.
3.  The user must first be trained by the employer in proper respirator use, in accordance with 

applicable safety and health standards, for the contaminant and exposure level in the assigned 
work area. It must meet all requirements of all applicable standards, including OSHA 29 CFR 
1910.134, and in Canada CSAZ 94.4, e.g. training, fit testing, medical evaluation, and applicable 
OSHA substance specific standards.

4.  The vapors, gases, dusts, mists, fumes, and other contaminants, which can be dangerous to your 

health, include those which you cannot see, taste, or smell.

5.  Check with your supervisor for the appropriate cartridges and/or filters for the contaminants in 

your work area.

6.  A qualitative or quantitative fit test must be performed before a respirator is assigned. Refer to 

current OSHA 29 CRF 1910.134 (f).

RESTRICTIONS

1.  This respirator does not supply oxygen and must not be used in atmospheres containing less 

than 19.5% oxygen.

2.  Do not remain in contaminated area if any physical distress occurs, for example breathing 

difficulty, dizziness or nausea.

3.  Leave contaminated area and replace respirator and/or cartridge or filter if it is damaged, 

distorted, a proper fit cannot be obtained, you taste, smell or become irritated by contaminants, 
or breathing becomes difficult.

4.  Do not alter, modify, or abuse this respirator.
5.  Dispose of facepiece, and/or cartridge and disks/filters according to your employer’s policy and 

applicable regulations.

6.  N, R or P filters are required for particulates.
7. 

When oil mists are present,

 either alone or in combination with solid particulates. Do not use the 

R filters for longer than one eight-hour shift. Dispose no later than eight hours after first use, do 
not exceed 50X PEL depending on whether the user was quantitatively or qualitatively fit tested 
(see Do Not Use Against, Item 2) and 200 mg loading per respirator. It is the user’s responsibility 
to know the PEL and concentration of the contaminant, the maximum work rate of the employee, 
and any other work site-specific information to calculate the loading of the filter. Where oil mists 
are present do not use N filters.

8.  Dispose of all cartridges no later than thirty days after a) first use, and/or b) removing from 

sealed packaging.

9.  Use cartridges, filters, and facepieces before the “use by” expiration date printed on packaging.

Содержание 9900

Страница 1: ... remplaçables Máscara completa Con cartuchos y filtros reemplazables Instructions for Use and Maintenance Including NIOSH Approval Label Instructions d utilisation et d entretien Comprend l étiquette d approbation NIOSH Instrucciones para uso y mantenimiento Incluye la etiqueta de aprobación NIOSH 9900 ...

Страница 2: ... heats of reaction 4 Sandblasting 5 Oil based mists with N filters WARNING TO USER 1 Follow all instructions and warnings on the use of this respirator and wear during all times of exposure Failure to do so will reduce respirator effectiveness wearer protection and may result in sickness or death 2 For proper use ask your supervisor 3 The user must first be trained by the employer in proper respir...

Страница 3: ...ylamine chlorine chlorine dioxide hydrogen chloride hydrogen fluoride hydrogen sulfide sulfur dioxide formaldehyde and organic vapors P100 Particulate Filter against all particulate aerosols SIGNATURE SELECT STACKED CARTRIDGES XP100 P100 Particulate Pancake Filter 99 97 filter efficiency level effective against all particulate aerosols XP100 OV AG P100 Particulate Pancake Filter 99 97 filter effic...

Страница 4: ...ational Standards for Respiratory Protection ANSI Z88 2 2015 Fit tests should be performed annually or more frequently if dental surgery weight change or other factors occur which may affect the respirator fit Positive Negative Facefit Check Conduct a positive and a negative facefit check each time the respirator is worn Positive Pressure Facefit Check Place palm of hand over exhalation valve cove...

Страница 5: ...spirators are approved only in the following configurations TC Protection1 Retainer CAUTIONS AND LIMITATIONS2 9100 9200 9300 9900 G01 G03 G08 G71 G73 G78 GX70 G95P XP100 XP100 OV AG 172 23C 1578 OV SD HC CL X X X X 84A 6809 P100 X X X X 84A 3173 P100 X X X X X 23C 1526 OV X X X X 23C 2839 AM CD CL FM HC HF HS MA OV SD X X X X 84A 3332 P95 OV X X X X X X 84A 3334 P95 OV SD HC CL X X X X X X 84A 273...

Страница 6: ...s gaz ou les émanations ayant de faibles propriétés d avertissement ou qui génèrent de hautes températures de réaction 4 Sablage 5 Embruns huileux avec filtres N AVERTISSEMENT POUR L UTILISATEUR 1 Suivez tous les avertissements et les instructions d utilisation de ce respirateur et portez le pendant toute la période d exposition Le non respect de cette consigne réduira l efficacité du respirateur ...

Страница 7: ... organiques le bioxyde de soufre le chlorure d hydrogène le chlore et le fluorure d hydrogène jusqu à 50 fois la limite d exposition admissible PEL ou la limite OSHA si cette dernière est inférieure P100 Filtre à particules efficace contre tous les aérosols particulaires SIGNATURE SELECT FILTRES ET PORTE FILTRE G95P P95 Filtre plat à particules niveau d efficacité du filtre de 95 efficace contre t...

Страница 8: ...ues qui empêchent un contact direct entre votre visage et le bord du respirateur Ne portez pas de lunettes autres que celles approuvées pour le respirateur complet avec pièce faciale Safety Works Instructions d entretien d assemblage et d entreposage A Désassemblage 1 Enlevez les cartouches et ou les filtres 2 Désassemblez le harnais en enlevant les boucles de la pièce faciale 3 Enlevez le demi ma...

Страница 9: ...tors shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add and or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to user instructions and or maintenance manuals for information on use and maintenance of the respirators P NIOSH does not evaluate respirators a...

Страница 10: ...ales correspondientes 3 Gases o vapores con propiedades de advertencia deficientes o aquellos que generen un gran calor de reacción 4 Limpieza con chorro de arena 5 Neblina a base de aceite con filtros N ADVERTENCIA PARA EL USUARIO 1 Siga todas las instrucciones y advertencias acerca del uso de este respirador y úselo en todo momento que esté expuesto No cumplir con esto reducirá la efectividad de...

Страница 11: ...lado efectivo contra todos los aerosoles de material particulado SIGNATURE SELECT FILTROS Y SUJETADORES G95P P95 Filtro de disco plano para material particulado nivel de eficiencia del filtro de un 95 efectivo contra todos los aerosoles de material particulado 172 Sujetador de filtro Listado de productos MÁSCARA COMPLETA 9900 Máscara completa de elastómeros termoplásticos TPE CARTUCHOS SIGNATURE S...

Страница 12: ... física que pueda evitar el contacto directo entre la cara y el borde del respirador No use anteojos que no estén aprobados para el respirador de máscara completa de Safety Works Instrucciones de mantenimiento montaje y almacenamiento A Desmontaje 1 Quite los cartuchos y los filtros 2 Retire las hebillas de la máscara para desmontar el arnés 3 Retire la copa para nariz 4 Destornille el anillo de s...

Страница 13: ...llow the manufacturer s instructions for changing cartridges and filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add and or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to user instructions and or maintenance manuals fo...

Страница 14: ...26 27 Notes Notes ...