English
If because of an overload
or impacht on the money
platform the function of
the 6165 loadcell (weiging
element) is damaged. Then
a recalibration of the load
cell could help to recover the
function.
1.
Press
“OK”
to start the recalibration process.
2.
The device will start ‘taring’ and will proceed to ask to place a
500 gram weight* on the platform.
3.
After placing the 500 gram weight the device will automatically
start the calibration process. In the screen the text: “Sampling”
is blinking.
4.
When the process is done the device will display: Finished.
Please remove the weight form the money platform. The device
is now ready for usage.
* You can purchase a calibration weight of 500 grams on
www.safescan.com
. If you cannot find it on the website,
please contact us.
Select the region where you
will be using your Safescan
6165. Use the (
) buttons
to toggle between
“EUROPE”,
“UK”, “USA”, “S-E ASIA” and
“AUSTRALIA”
. Press
“OK”
to
confirm.
D. Region setting
E. Recalibrate loadcel