8
4.2 Reset to default factory settings
Press
[CLR]
and turn on the machine, “—DEF—”and “—H—” are displayed in the screen.
Press
[START]
to save and exit.
5.0 CURRENCY SOFTWARE UPDATE PROCEDURE
If security features of banknotes are change or new banknotes are issued, it could be necessary to update the
Safescan banknote counter with new currency software via the built in USB port (available for the 2660, 2665
& 2685 models). Contact Safescan for assistance: www.safescan.com
6.0 TROUBLESHOOTING & MAINTENANCE
6.1 Error messages after self-test
6.2 Cleaning sensors
For optimal performance it is needed to regularly clean the device.
Clean the hopper and stacker with the enclosed dry brush. Clean the inner parts with the enclosed cleaning note.
Place this note with the soft side up on the hopper and let the paper go through the device 3-5 times.
ERROR MESSAGE
Fluorescence sensor
Banknote feeding sensor
Banknote receiving sensor
Left counting sensor
Right counting sensor
Ext IR sensor
Internal memory fault
SOLUTION
Do not place or operate the machine under strong light
Remove banknote(s) or dust from the hopper
Remove banknote(s) or dust from the stacker
Remove banknote(s) or dust from the stacker
Remove banknote(s) or dust from the stacker
Remove banknote(s) or dust using an air duster