background image

Installation manual 

Vik Veg H2 

 

 

1.

 

Important 

Proper installation and repair is essential to ensure the systems maximum performance. 
 

2.

 

Description 

The Vik Veg H2 a steel road restraint system that is designed to enhance safety on the roads. 
The system has successfully been tested according to class H2 described in EN 1317-2. 
The  system  is  based  on  sigma  steel  posts  with  post  distance  of  1  meter  and  a  longitudinal  3mm  high 

strength steel guard rail A-profile with W-shaped backside beam. 
In a collision the system is designed in such a way that the A-profile (incl. backside beam) will break away 

from the post and stop the vehicle or/and lead it back on the road again.  
The bolts are an important part of the systems function and this manual should be read carefully before 

installation is started. 
 

3.

 

Level of performance  

According to EN-1317 

Post 

distance 

Containment 

level 

Working 

width [W] 

Dynamic 

deflection 

Impact 

severity 

level 

Vehicle 

intrusion 

class 

1m 

H2 

1,3 m (W4) 

1,1 m 

1,6 m (VI5) 

 

4. Installing 

4.1 Soil and placement 

The soil where the barrier is placed should be of sufficient quality to ensure the guardrails function. 

The posts should bend and not break up true the soil or be pulled up when the barrier is hit.  
 

4.2 Installing the posts 

The posts should be installed with a distance of 1 meter. 

The holes for the posts should normally be pre-drilled or pre-rammed before installing the post. They 
should be drilled to the correct level or deeper, to ensure that there is no need to ram the posts after they 
are placed.  

After alignment and height adjustment, parts of the hole around the post should be filled with gravel to 
lock the post in the correct position.

 

Содержание VikOrsta VIK Veg H2

Страница 1: ... w shaped backside beam installed on Sigma posts Installation manual 12 11 2018 Leverandør Vik Elvagata20 6893 Vik i Sogn Ørsta Strandgata 59 6150 Ørsta Tlf 47 57 69 86 50 firmapost vikorsta no Tlf 47 70 04 70 00 firmapost vikorsta no ...

Страница 2: ...tant 3 2 Description 3 3 Level of performance 3 4 Installing 3 4 1 Soil and placement 3 4 2 Installing the posts 3 4 3 Installing the profiles 4 4 4 After installation 4 5 Maintenance 4 5 1 Cleaning 4 6 Bolts and fasteners 5 7 Marking 5 8 Drawing 6 ...

Страница 3: ... manual should be read carefully before installation is started 3 Level of performance According to EN 1317 Post distance Containment level Working width W Dynamic deflection Impact severity level Vehicle intrusion class 1m H2 1 3 m W4 1 1 m B 1 6 m VI5 4 Installing 4 1 Soil and placement The soil where the barrier is placed should be of sufficient quality to ensure the guardrails function The pos...

Страница 4: ...e end of the following beam in the direction of traffic 4 4 After installation When the guardrail is installed and adjusted the holes around the post should be fully refilled 5 Maintenance There are no general inspections intervals for this guardrail itself Inspections intervals have to be determent based on local factors such as volume of traffic risk of damage climate etc The guard rail should b...

Страница 5: ...galvanized 60641 Bolt M16x25 692316000 Flange nut M 16 1 1 60640 Connecting bolt M16x25 mm hot dip galvanized 60641 BoltM16x25 60643 Nut M16 60642 Washer M16 1 1 1 Placement of bolts nuts and washers Article 60614 60615 Article 60639 60640 Note Please check that all bolts fasteners are placed correct and all bolts washer nuts connections are normally proper fastened tighten 7 Marking If everything...

Страница 6: ...Installation manual Vik Veg H2 6 8 Drawing ...

Отзывы: