InstallatIon - step 2/6
mount the Power Control unit
Ⓒ
.
OUT
IN
PE
L/N
L
PE
N
L
L
230V 16A
400V 10A
230V 16A
400V 10A
230V 16A
400V 10A
MAX
MAX
MAX
L1
L2
L3
MICRO DISCONNECTION
ѥ
WARNING
Make sure that there is no power supply
to the cooker and the oven by removing
their fuses. Also ensure that the cooker is
switched off.
OUT-wires are always energized when the
power control unit is connected to the elec-
trical network. If a wire is loose, it must be
properly covered.
If the element voltage of the cooker is 400
V, the fuse can only be maximum of 10 A.
If the element is 230 V, the fuse can only be
maximum of 16 A.
Do not install the Power Control Unit to
excessive heat: Operational ambient tem-
perature is +5 … +40°C.
⚐
ATTENTION
Power Control Unit requires a neutral
wire to operate.
Install the power control unit
Ⓒ
so that it
is not exposed to moisture. Check that all
cables can move freely.
Install the Power Control unit PCu3.
ѧ
HINT
If you are replacing a cooker, press the
adjustment mode button
❼
for five sec-
onds until you hear a signal. Continue the
installation according to step 3/6.
oFF