![background image](http://html1.mh-extra.com/html/safeline/sl6/sl6_manual_3321571016.webp)
16
LED1
LED2
LED3
SafeLine SL6+ v.3.9.0 EN
Reset
*Minimum signal strength for using GSM interface.
LED indication
front panel
LED 1 indicates the power supply status
Continuous green
Mains power supply OK
Flashing red (400/400 ms)
Battery operated, with power to the emergency light.
Continuous red
Battery operated, no power to the emergency light
LED 2 indicates active alarm and battery condition
Light off
No active alarm/battery OK.
Rapidly flashing yellow (200/200 ms)
Active alarm not reset
Flashing red (400/400 ms)
Battery check in progress.
Continuous red
Battery test failure/no battery connected
LED 3 indicates the phone line's status
Flashing green (100/100 ms)
Fire mode activated.
Flashing green (400/400 ms)
Call connection in progress.
Slowly flashing green (200/4600 ms)
Telephone line connected. GSM network OK.
Continuous green
Call connected.
Flashing yellow (100/100 ms)
Incoming call.
Flashing red
(400/400 ms)
PSTN: No telephone line connected.
GSM: Searching for GSM network.
Continuous red
No SIM card (when using GSM).
Reset button
Press for 3 sec
Show GSM signal strength (see table below).
Press 3 times
Start a self test (b bus initialization).
Press once
Resets an active alarm. Aborts calls in progress.
Press 5 sec - release
SL6+ turns off.
NOTE!
Refers to battery powered only!
LED
1 2 3
GSM signal
strength
= 100 %
>= 85 %
>= 70 %
>= 55 %
>= 30 %*
>= 15 %
>= 0 %