LED INDICATION

Yellow LED

Light off:

Telephone line OK, call 
terminated

Flashing once every 5 
seconds:

Telephone line 

not

 OK.

Flashing twice every second:

Emergency signal button 
active. 

Yellow steady:

Activated alarm. Remains lit 
until reset.

Green LED

Light off:

Telephone line 

not

 OK.

Flashing once every 5 
seconds:

Unit is OK. Phone line is OK.

Flashing two times every 5 
seconds:

Alarm fi lter activated.

Green steady

:

Call connected.

Continuous fl ashing:

Telephone in confi 

guration 

mode.

System LED

Flashing once every 5 
seconds:

Telephone line OK.

Flashing two times every 5 
seconds:

No telephone connection 
available.

Flashing twice every second:

Calling out

Light steady:

Call connected.

Flashing rapidly:

Incoming call.

Yellow LED “Call in progress“

The Yellow Pictogram LED, is 
lit as soon as the alarm button 
is pressed longer than the set 
delay

Standard (*78*0#)

Strictly EN81-28 (*78*1#)

Green LED “Call connected“

The Green pictogram LED turns 
on as soon as the SafeLine unit 
detects a responding voice. 
The LED is turned off when the 
call is terminated.

Yellow LED

Flashing twice every second:

Emergency signal button 
active. 

Yellow steady:

Activated alarm. Remains lit 
until reset.

Green LED

Green steady

:

Call connected.

System LED

The system LED is located on 
the backside of the unit.

Содержание MX2

Страница 1: ...SafeLine MX2 Installation manual ENGLISH V 4 02 10 2010 Small inexpensive and intelligent Probably the world s smallest EN81 28 compatible lift telephone...

Страница 2: ...TECHNICAL DATA Power Supply voltage 10 30 VDC Current consumption max 50 mA Emergency signal button Can be set as NO or NC 10 30VDC Auxillary input Can be set as NO or NC 10 30VDC Size HxWxD 130x78x1...

Страница 3: ...onal safety 4 Component list 5 Measurements 6 Wiring diagram 7 Wiring diagram SafeLine MX2 on PSTN line 8 LED indication 9 Programming interfaces 10 Programming method 11 Programming unit numbers 12 P...

Страница 4: ...stallation or illegal changes repairs or additions Claims under warranty are likewise excluded in such cases The technical data is the latest available The manufacturer accepts no liability arising fr...

Страница 5: ...1 2 5 Installation ENGLISH V 4 02 COMPONENT LIST 1 RJ45 connector For power emergency button phone line and auxillary input 2 RS232 PC connection For firmware update and programming with SafeLine Pro...

Страница 6: ...02 Flush mount SafeLine MX2 with pictograms Article number SLMX_Rec Pic Flush mount SafeLine MX2 with pictograms and emergency alarm button Article number SLMX_Rec PicB Surface mount SafeLine MX2 wit...

Страница 7: ...d cable Colours when using flat cable Voltage supply 0V Voltage supply 0V Voltage supply 10 30V Voltage supply 10 30V Additional input filter Additional input filter Alarm button Alarm button Telephon...

Страница 8: ...are copyrighted by law Installation ENGLISH V 4 02 Daisy chain wiring serial wiring Parallel wiring WIRING DIAGRAM SAFELINE MX2 ON A PSTN LINE MAX 9 UNITS Phone line in Phone line in Unit numbers can...

Страница 9: ...System LED Flashing once every 5 seconds Telephone line OK Flashing two times every 5 seconds No telephone connection available Flashing twice every second Calling out Light steady Call connected Flas...

Страница 10: ...nstallation or at site after installation with a programming cable PCable Remote programming For remote programming you can use any PSTN tone dial phone Dial the phone number of the SafeLine Enter the...

Страница 11: ...e programming Start programming One long beep only last code has to be reentered Programming mode Enter code and setting Refer to parameter list Press 00 Call has ended 2 short beeps 2 short beeps No...

Страница 12: ...umber 1 Program unit as number 2 9 End Programming Press the next unit number repeatedly until hearing 3 beeps Enter the password Terminate programming First unit answers The next unit answers Unit pr...

Страница 13: ...e number to emergency call centre to 45645687 Set phone number 42345687 for test alarm Send test alarm every third day Set test alarm protocol to P100 Set alarm button delay to 10 seconds PROGRAMMING...

Страница 14: ...CPC Change this only if your alarm operator is using any of the mentioned protocols Call type 2nd number 22 Call type 3rd number 23 Call type 4th number 24 Call type LMS number 30 LMS Lift Monitoring...

Страница 15: ...DATA COMMENTS Emergency signal in speaker 71 The speaker siren will sound at emergency call 1 On Default 0 Off Ring tone timeout 72 Number of ring signals before dialling the next number Additional in...

Страница 16: ...Alarm button delay time 87 Delay time from pressing the alarm button until activating the alarm 00 25 seconds Default 05 Alarm button type 89 0 Normally open contact NO Default 1 Normally closed conta...

Страница 17: ...5 times Short tone in the speaker Green LED flashes every 5 sec if valid telephone line connected and set to standard Yellow LED flashes every 5 sec No connection Yellow LED flashes 5 times Long tone...

Страница 18: ...on Calling 1st phone number Wait 1 minute Calling 2nd phone number Calling 4th phone number Calling 3rd phone number Line missing or busy Emergency alarm activated Receiving tone No No No No No Yes Ye...

Страница 19: ...ar check the microphone Poor distorted sound quality Volume might be set too loud Lower the volume and check again Interfering noise when the call is connected The problem might be due to induction in...