Wire from the negative (-) terminal screw on the receiver (figure 1) to
the "GDN" screw on the siren (figure
9
).
2.
Wire from the positive (+) terminal screw on the receiver to the #1 or #2
sc
rew on the siren. #1
is a continuous siren sound (for set time
duration), while #2 is an alternating siren sound (for set time duration).
3.
The "SW" screws are not used in this application.
4.
Finish setup by going to
Step 8
in section titled "
Connecting a 12V DC
accessory to the ERA-DCRX Receiver.
"
TECHNICAL SUPPORT
If you encounter any difficulty in the operation of this product
after r
eading
the
m
anual, please contact us. You can reach us by phone at
904-245-1184
from 8:
0
0 AM to 5:00 PM Monday through Friday (
Eastern
Standard Time). We
will be happy to answer your questions and help you in any way we can.
WARRANTY
Safeguard Supply
warrants this product to be free of defects in
material
and
workmanship for a period of one year from the date of purchase. This
warranty does not cover damage resulting from accident, abuse, act of god
or improper operation. If this product does become defective, simply return
it to
Safeguard Supply
. Please include a note describing the troubles along
with your name and return address as well as the original sales receipt. If the
product is covered under warranty it will be repaired or replaced at no
charge. If it is not covered by warranty, you will be notified of any charges
before work is done.
Safeguard Supply
2260 Moon Station Ct. NW #110
Kennesaw, GA 30144
Phone: (
678
)
214
-
4212
www.
safeguardsupply
.com
Wiring the SS-PSIREN-W
The instructions here pick up from Step 6 in the section "Connecting 12V
DC Accessories to the ERA-DCRX Receiver."
Adjusting the 12V DC Output Duration
The ERA-DCRX will supply 12V DC power to each of the zones. The duration of the
output may be adjusted using the dip-switches as seen in Figure 2 below.
•
The duration may be adjusted t 5 seconds, 10 seconds, 1 minute, and 2 minutes.
This means, when a zone is triggered, it will supply 12V DC power for the
specified duration.
•
The duration setting will apply to all zones.
•
In the diagram
(figure 8)
, the dip-switches to the r
i
gh
t
corres
p
ond
to
duration
that the receiver will output power.
•
Adjust the dip-switches to the desired output time.
Using the C-Form Relay
The last 3 screws in the terminal block, labeled "Relay" in in figure 7, may be used for
integration to 3rd party devices that accept "Normally Open (N/O) or "Normally
Closed" (N/C) connections. Please consult the device you are integrating with for
specifications on how to integrate the device using a C-Form relay. It is important to
note that this connection DOES NOT supply power to the integrated device, rather,
the device must have it's own power supply.
Examples of Connecting Devices to the 12V DC Outputs and the C-FORM
Relay
The C-Form relay can work with any combination of zones by setting the dip-
switches in figure
10
. By default, the C-FORM relays are set to work with all
zones.
The diagram below provides a basic overview of how devices may be connected
to other devices. In the diagram, a 12V DC strobe is connected to zone 1. When
a transmitter is triggered that is programmed to zone 1, the strobe light will
flash. In zone 2, a siren is connected,and it will sound when that zone is
triggered. A Fire Alarm Bell is connected to the Relay and will sound when the
asscoicated zone to the Relay is triggered. Note, an external power supply must
be provided for the device connected to the Relay.