damaging the wires. Please also ensure that the display power is OFF while the following
procedure is carried out.
TOOLS REQUIRED:
1 x 2.5mm Hex Head Allen key
1 x 2mm Flat Head Screwdriver
PROCEDURE:
1. Loosen the gland(s) on the back plate to allow the cable(s) to move freely through the
gland(s).
2. To remove the back plate, loosen and remove the 8 x M3 x 12mm socket head cap
screws completely using a 2,5mm Allen key. Support the plate at all times to ensure
that the plate does not fall.
3. Carefully lift the back plate approximately 130mm away from the aluminium housing
(do not hang back panel from wiring).
4. The buzzer is connected to the main board by red and black wires terminated with a
white Molex connector; this connects onto the receptacle connector on the main board.
To remove the back plate completely carefully unclip the connector from its receptacle.
5. The USB is connected to the main board by brown, blue, white & black wires
terminated with a USB A connector. To remove the back plate completely carefully
unplug the connector from its receptacle.
6. Remove the back plate completely.
7. Make sure the 2A blade fuse is not damaged and is inserted securely.
8. Connect the power wires to the following terminals using the 2mm flat head
screwdriver:
Te+
-
Wire # 1
-
+ Supply (10-36VDC)
Terminal --
-
Wire #2
-
- Supply (Earth/Ground)
9. To close the display:
Ensure all power wires are securely in the terminals.
Connect the buzzer’s Molex plug to the circuit boards reciprocal connector.
Connect the USB A connector to the circuit boards reciprocal connector.
Position back cover on display box making sure not to pinch any wires and
replace the 8 x M3 x 12mm socket head cap screws.
Gently pull wire(s) back through glands until slack has been taken up and then
tighten gland(s).