5
To meet the requirements of SSF 3522 lock class 3, 4 and 5 you have to activate the SSF 3522 function in
the display of control unit: Menu 20. SSF 3522 :
Enabled : YES
.
The control unit should also be installed in a minimum lock class 3 secured area.
Activation of the SSF 3522 mode implicate following adjustment of the relay output:
•
Lockbolt out active indikating 7 sec. Default setting: 10s
•
Lockbolt in (unlocked) active indicating 7 sec. Default setting: 10s
•
Alarm active indikating 30 sec. Default setting: 30s
•
Opening time of activation 10 sec. Default setting: 10s
Separate output for acoustic indicator that indicate if the blocking bolt or other blocking elements is
prevented in the exchange between full locked position, unlocked position or not dead locked. This out-
put should activate minimum 2 sec after the blocking bolt or other blocking elements should have been
in its end position, and be activated minimum 30 sec maximum 2 min. This output will be switched of if
the blocking bolt or other blocking elements reaches full locked position.
NOTICE
All components of the ”lock unit” (lockcase, strikeplate and reinforcing plate) must have the same classi-
fication according to SSF 3522.
CALCULATION OF CABLE DIMENSIONS
SSF 3522
Lock
SAFETRON 6100
SAFETRON 6200
SAFETRON 6300
SAFETRON 6500
SAFETRON 6600
•
Read and follow the installationmanual.
•
Motor lock should be used primarily electronically for best function.
•
Service like tex. adjustment and lubricate shall be made by an certificated installer.
Avoid the use of data/tele/signal cables (singel conductor) with cablearea between 0,1 - 0,2 as an
powersupply for the motorlock. Safetron cannot guarantee proper function in case of not following
these recommendations. Se schedule below.
Recommended minimum cable dimension between power supply and the control unit
NOTICE
It is important that powersupplie for the Control unit has the right cable dimention, to prevent power
falure that interfear with the funktion. Installation with more then one unit such as lock/access control/
card reader/control units, the total powersupplie must be concidered in calculation of cableareas.
Cable length
0-10m
11-20m
21-40m
61-80m
81-100m
12-24 VDC
0,17mm
2
0,34mm
2
0,68mm
2
1,36mm
2
1,7mm
2
RECOMMENDATIONS UPON INSTALLATION
Содержание CU2
Страница 1: ...CONTROL UNIT CU2 Instruction manual 20211129 ...
Страница 6: ...6 OK Anslutning Lås 2 LOCK 2 TERMINAL LAYOUT ...
Страница 15: ...SAFETRON 6100 50 20 42 42 111 170 R11 22 225 200 R16 50 4 140 28 40 27 15 INSTALLATION OF LOCK CASE ...
Страница 16: ...50 20 42 42 111 170 R11 22 225 200 R16 50 4 140 28 40 27 8 RUBRIK SAFETRON 6200 16 INSTALLATION OF LOCK CASE ...
Страница 17: ...8 RUBRIK SAFETRON 6300 220 23 138 41 30 176 59 26 35 13 50 20 16 6 58 120 50 10 17 INSTALLATION OF LOCK CASE ...